Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures

被引:13
|
作者
Deprez, S. [1 ,2 ]
de Ruiter, Michiel B. [3 ]
Bogaert, S. [4 ]
Peeters, R. [1 ,2 ]
Belderbos, J. [5 ]
De Ruysscher, D. [6 ,7 ]
Schagen, S. [3 ]
Sunaert, S. [1 ,2 ]
Pullens, P. [8 ,9 ]
Achten, E. [4 ]
机构
[1] Univ Hosp Leuven, Dept Radiol, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[3] Netherlands Canc Inst, Div Psychosocial Res & Epidemiol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[4] Ghent Univ Hosp, Dept Radiol, Ghent, Belgium
[5] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[6] Maastricht Univ, Med Ctr, GROW Sch, Dept Radiat Oncol,Maastro Clin, Maastricht, Netherlands
[7] Katholieke Univ Leuven, Radiat Oncol, Leuven, Belgium
[8] Univ Hosp Antwerp, Dept Radiol, Edegem, Belgium
[9] Antwerp Univ, Edegem, Belgium
关键词
Multi-center; Reproducibility; Structural MRI; Diffusion tensor imaging; Resting state fMRI; MRI; RELIABILITY; MULTISITE; PHANTOM; BRAIN; CONNECTIVITY; VARIABILITY; ASSURANCE; NOISE; WATER;
D O I
10.1007/s00234-018-2017-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer. Methods Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers. Results We report average coefficients of variation (CV) below 5% for intrascanner, intravendor, and intervendor reproducibility for both structural and diffusion imaging metrics, except for diffusion metrics obtained from tractography with average CVs ranging up to 7.8%. Additionally, resting-state fMRI showed stable temporal SNR and reliable generation of subjects DMN across vendors and time points. Conclusion These findings indicate that the presented multi-site MRI acquisition protocol can be used in a longitudinal study design and that pooling of the acquired data as part of the phase III longitudinal HA-PCI project is possible with careful monitoring of the results of the half-yearly QA assessment to follow-up on potential scanner-related longitudinal changes in image quality.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 50 条
  • [1] Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures
    S. Deprez
    Michiel B. de Ruiter
    S. Bogaert
    R. Peeters
    J. Belderbos
    D. De Ruysscher
    S. Schagen
    S. Sunaert
    P. Pullens
    E. Achten
    Neuroradiology, 2018, 60 : 617 - 634
  • [2] Reproducibility of Structural and Diffusion Tensor Imaging in the TACERN Multi-Center Study
    Prohl, Anna K.
    Scherrer, Benoit
    Tomas-Fernandez, Xavier
    Filip-Dhima, Rajna
    Kapur, Kush
    Velasco-Annis, Clemente
    Clancy, Sean
    Carmody, Erin
    Dean, Meghan
    Valle, Molly
    Prabhu, Sanjay P.
    Peters, Jurriaan M.
    Bebin, E. Martina
    Krueger, Darcy A.
    Northrup, Hope
    Wu, Joyce Y.
    Sahin, Mustafa
    Warfield, Simon K.
    FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2019, 13
  • [3] Inter-vender and test-retest reliabilities of resting-state functional magnetic resonance imaging: Implications for multi-center imaging studies
    An, Hyeong Su
    Moon, Won-Jin
    Ryu, Jae-Kyun
    Park, Ju Yeon
    Yun, Won Sung
    Choi, Jin Woo
    Jahng, Geon-Ho
    Park, Jang-Yeon
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 125 - 130
  • [4] Combined resting state functional magnetic resonance imaging and diffusion tensor imaging study in patients with idiopathic restless legs syndrome
    Zhuo, Yaoyao
    Wu, Yuncheng
    Xu, Yanhong
    Lu, Lunbo
    Li, Ting
    Wang, Xifu
    Li, Kangan
    SLEEP MEDICINE, 2017, 38 : 96 - 103
  • [5] Resting-State Functional Magnetic Resonance Imaging and Probabilistic Diffusion Tensor Imaging Demonstrate That the Greatest Functional and Structural Connectivity in the Hand Motor Homunculus Occurs in the Area of the Thumb
    Hamidian, Shaminta
    Vachha, Behroze
    Jenabi, Mehrnaz
    Karimi, Sasan
    Young, Robert J.
    Holodny, Andrei I.
    Peck, Kyung K.
    BRAIN CONNECTIVITY, 2018, 8 (06) : 371 - 379
  • [6] Microscopic magnetic resonance imaging (μMRI) of trabecular bone at the distal radius -: A multi-center reproducibility study
    Gomberg, B. R.
    Seaman, P.
    Kleerekoper, M.
    BONE, 2007, 40 (06) : S201 - S202
  • [7] Functional and diffusion tensor magnetic resonance imaging of the sheep brain
    Wonhye Lee
    Stephanie D. Lee
    Michael Y. Park
    Lori Foley
    Erin Purcell-Estabrook
    Hyungmin Kim
    Seung-Schik Yoo
    BMC Veterinary Research, 11
  • [8] Functional and diffusion tensor magnetic resonance imaging of the sheep brain
    Lee, Wonhye
    Lee, Stephanie D.
    Park, Michael Y.
    Foley, Lori
    Purcell-Estabrook, Erin
    Kim, Hyungmin
    Yoo, Seung-Schik
    BMC VETERINARY RESEARCH, 2015, 11
  • [9] Imaging of Brain Tumors: Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging
    Gupta, Ajay
    Shah, Akash
    Young, Robert J.
    Holodny, Andrei I.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2010, 20 (03) : 379 - +
  • [10] Comparison of scalar measures used in magnetic resonance diffusion tensor imaging
    Bahn, MM
    JOURNAL OF MAGNETIC RESONANCE, 1999, 139 (01) : 1 - 7