Revised Evaluation of Hemodilution Response in the Semi-Closed Loop Infusion System

被引:1
|
作者
Markevicius, Vytautas [1 ]
Cincikas, Darius [2 ]
Porvaneckas, Narunas [3 ]
Stankevicius, Edgaras [4 ]
Navikas, Dangirutis [1 ]
Andriukaitis, Darius [1 ]
Sipylaite, Jurate [2 ]
Svediene, Saule [2 ]
Uvarovas, Valentinas [3 ]
Satkauskas, Igoris [2 ]
Kvederas, Giedrius [3 ]
Valinevicius, Algimantas [1 ]
Zilys, Mindaugas [1 ]
Andrijauskas, Audrius [2 ]
机构
[1] Kaunas Univ Technol, Dept Elect Engn, Studentu St 50-418, LT-51368 Kaunas, Lithuania
[2] Vilnius State Univ, Fac Med, Clin Anaesthesiol & Intens Care, Siltnamiu St 29, LT-04130 Vilnius, Lithuania
[3] Vilnius State Univ, Fac Med, Clin Rheumatol Orthopaed Traumatol & Reconstruct, Siltnamiu St 29, LT-04130 Vilnius, Lithuania
[4] Lithuanian Univ Hlth Sci, Inst Physiol & Pharmacol, A Mickeviciaus St 9, LT-44307 Kaunas, Lithuania
关键词
ACDSS; SCLIS; mVLT; hemoglobin; fluids; PULSE PRESSURE VARIATIONS; FLUID RESPONSIVENESS; ZONE APPROACH; GREY ZONE; TESTS;
D O I
10.5755/j01.eee.22.1.12826
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A mini volume loading test (mVLT) method is used for decision making in our prototype semi-closed loop infusion system (SCLIS). The mVLT fluid protocol consists of hemodilution response-guided mini fluid challenges. Each mini fluid challenge (MFC) consists of a 2.5 ml kg(-1)-5 ml kg(-1) crystalloid bolus infused over 2 min-5 min and followed by a 5 min period with no fluids. Arterial plasma dilution efficacy (aPDE) of a MFC is calculated from invasively measured hemoglobin (aHb) before and after each MFC. Capillary plasma dilution efficacy (cPDE) is calculated from non-invasively measured hemoglobin (SpHb). The zero or negative arterio-capillary plasmadilution efficacy difference (acPED <= 0 p.d.u.) is an indication of hemodilution non-response and imminent edema. However, it requires both invasive and non-invasive hemoglobin measurements. A non-invasive assessment of hemodilution response within the mVLT method would increase its practical application and reduce costs further enhancing its applicability in the SCLIS. This possibility exists if the cPDE could reliably predict the acPED value or the hemodilution response (the presence of acPED within a range of > 0) or non-response (acPED <= 0). We report a retrospective observational study in an elective total knee arthoplasty (TKA) setting. The 2.5 ml kg(-1) boluses were used in six MFCs in both pre-and post-operative mVLT sessions. The primary objective was to assess the accuracy of cPDE in predicting the hemodilution response using the receiver operating characteristic (ROC) curve and gray zone approaches. Our secondary objective was to investigate the feasibility of a statistical optimization method (SOM) in predicting the acPED. The analysis included 480 paired values of cPDE and acPED. The best cut-off value for cPDE was 0.015 p.d.u. (specificity = 0.84, sensitivity = 0.90). The gray zone identified a range of cPDE values between 0.013 and 0.028 (p.d.u.) for which the hemodilution response could not be indicated reliably. The 14 % of the cPDE values were in this range. The non-invasive evaluation of hemodilution response is acceptably accurate in the perioperative TKA setting. The mVLT algorithm within our prototype SCLIS was upgraded by implementing the results of the present study.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [21] Position error compensation of semi-closed loop servo system using support vector regression and fuzzy PID control
    C. Deng
    S. Q. Xie
    J. Wu
    X. Y. Shao
    The International Journal of Advanced Manufacturing Technology, 2014, 71 : 887 - 898
  • [22] Guided-wave optical pressure sensor with semi-closed space under the diaphragm: step response in relation to the area of a small hole of a semi-closed space
    Sato, Kaoru
    Ohkawa, Masashi
    Sekine, Seishi
    Sato, Takashi
    PHOTONIC APPLICATIONS FOR AEROSPACE, TRANSPORTATION, AND HARSH ENVIRONMENTS, 2006, 6379
  • [23] Position error compensation of semi-closed loop servo system using support vector regression and fuzzy PID control
    Deng, C.
    Xie, S. Q.
    Wu, J.
    Shao, X. Y.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 71 (5-8): : 887 - 898
  • [24] Experimental observation of flow instability in a semi-closed two-phase natural circulation loop
    Kim, JM
    Lee, SY
    NUCLEAR ENGINEERING AND DESIGN, 2000, 196 (03) : 359 - 367
  • [25] Evaluation of effects of shellfish aquaculture and capture fishery on a semi-closed bay ecosystem
    Han, Dongyan
    Chen, Yong
    Zhang, Chongliang
    Ren, Yiping
    Xu, Binduo
    Xue, Ying
    ESTUARINE COASTAL AND SHELF SCIENCE, 2018, 207 : 175 - 182
  • [26] INFUSION OF VECURONIUM CONTROLLED BY A CLOSED-LOOP SYSTEM
    DEVRIES, JW
    ROS, HH
    BOOIJ, LHDJ
    BRITISH JOURNAL OF ANAESTHESIA, 1986, 58 (10) : 1100 - 1103
  • [27] INFUSION OF PANCURONIUM CONTROLLED BY A CLOSED-LOOP SYSTEM
    TREFFERS, R
    ROS, HH
    BOOIJ, LHDJ
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1990, 7 (01) : 19 - 23
  • [28] Structural evaluation of a compact, semi-closed W-shaped divertor system for JT-60U
    Onozuka, M
    Morimoto, M
    Inoue, M
    Umakoshi, T
    Shimizu, K
    Sakurai, S
    Hosogane, N
    Masaki, K
    FUSION ENGINEERING AND DESIGN, 1999, 45 (01) : 41 - 53
  • [29] THERMODYNAMIC COMPARISON OF SEMI-CLOSED AND OPEN-LOOP GAS-TURBINE ENGINE AIR COOLING SYSTEM EFFECTIVENESS.
    Manushin, E.A.
    Soviet Aeronautics (English translation of Izvestiya VUZ, Aviatsionnaya Tekhnika), 1981, 24 (01): : 15 - 19
  • [30] FULL SYSTEM OF EQUATIONS FOR NONSTEADY PROCESSES OF POWDER COMBUSTION IN SEMI-CLOSED VOLUME
    GOSTINTSEV, YA
    POKHIL, PF
    SUKHANOV, LA
    DOKLADY AKADEMII NAUK SSSR, 1970, 195 (01): : 137 - +