Adhesions to sutures, tackers, and glue for intraperitoneal mesh fixation: an experimental study

被引:14
|
作者
Schreinemacher, M. H. F. [1 ]
van Barneveld, K. W. Y. [1 ]
Peeters, E. [2 ]
Miserez, M. [2 ]
Gijbels, M. J. J. [3 ,4 ]
Greve, J. -W. M. [5 ]
Bouvy, N. D. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Gen Surg, NL-6202 AZ Maastricht, Netherlands
[2] Katholieke Univ Leuven, Dept Abdominal Surg, Louvain, Belgium
[3] Maastricht Univ, Med Ctr, Dept Mol Genet, NL-6202 AZ Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Pathol, NL-6202 AZ Maastricht, Netherlands
[5] Atrium Med Ctr, Dept Gen Surg, Heerlen, Netherlands
关键词
Abdomen; Ventral hernia repair; Surgical mesh; Fixation; Adhesions; INCISIONAL HERNIA REPAIR; POLYTETRAFLUOROETHYLENE MESH; FIBRIN SEALANT; METAANALYSIS; STRENGTH; PREVENTION; TRIAL;
D O I
10.1007/s10029-013-1192-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intraperitoneal mesh fixation for hernia repair is associated with adhesion formation. In this experimental study, adhesions against absorbable and non-absorbable fixation methods were compared. Six commercially available fixation methods were placed intraperitoneally in rats with a small pore polypropylene mesh coated on one side with ePTFE (Intramesh T1(A (R))). Two non-absorbable fixation methods: Prolene(A (R)) (polypropylene) sutures and Protack(A (R)) (titanium) tackers. Four absorbable methods: Vicryl(A (R)) sutures (polyglactin), Absorbatack(A (R)) and Permasorb(A (R)) tackers (both mixes of lactic and glycolic acids) and Tisseel Duo(A (R)) (fibrin glue). Adhesions and histology were studied at 7 and 90 days follow-up. In addition, fixation methods were placed without mesh, in order to study the reaction to the fixation method per se. No adhesion formation, but also inadequate mesh fixation was found with Tisseel Duo(A (R)), which had been completely resorbed at 7 days follow-up. Vicryl(A (R)) sutures could no longer be detected at 90 days follow-up and were associated with a favorable adhesion profile. All other fixation methods were still intact 90 days after implantation. When placed without mesh, adhesion formation was significantly less than placed with a mesh (18 vs. 93 %, P < 0.001). Without mesh, adhesions were worst with Permasorb(A (R)) tackers. Absorbable fixation methods such as polyglactin sutures and fibrin glue show a favorable adhesion profile compared to longer-term absorbable or non-absorbable fixation methods. However, before using fibrin glue as a single fixation method more research is required.
引用
收藏
页码:865 / 872
页数:8
相关论文
共 50 条
  • [21] THE MORPHOLOGY OF INTRAPERITONEAL ADHESIONS - AN EXPERIMENTAL-STUDY IN RATS
    ROTHE, M
    ASCHERL, R
    WEICHENMEIER, I
    HALLMANN, U
    WOLFL, I
    HOSS, C
    BLUMEL, G
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1982, 358 : 588 - 588
  • [22] SAFETY AND EFFICACY OF ABSORBABLE AND NON-ABSORBABLE FIXATION SYSTEMS FOR INTRAPERITONEAL MESH FIXATION: AN EXPERIMENTAL STUDY IN SWINE
    Kapoulas, Spyridon
    Papalois, Apostolos
    Papadakis, Georgios
    Tsoulfas, Georgios
    Christoforidis, Emmanouil
    Papaziogas, Basileios
    Schizas, Dimitrios
    Chatzimavroudis, Grigorios
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [23] Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine
    Kapoulas, S.
    Papalois, A.
    Papadakis, G.
    Tsoulfas, G.
    Christoforidis, E.
    Papaziogas, B.
    Schizas, D.
    Chatzimavroudis, G.
    HERNIA, 2022, 26 (02) : 567 - 579
  • [24] Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine
    S. Kapoulas
    A. Papalois
    G. Papadakis
    G. Tsoulfas
    E. Christoforidis
    B. Papaziogas
    D. Schizas
    G. Chatzimavroudis
    Hernia, 2022, 26 : 567 - 579
  • [25] INTRAPERITONEAL ADHESIONS FOLLOWING APPENDECTOMY - AN EXPERIMENTAL-STUDY
    PITKIN, J
    AUSTRALIAN PAEDIATRIC JOURNAL, 1980, 16 (02): : 153 - 153
  • [26] THE EFFECT OF FIBRIN GLUE AND PERITONEAL GRAFTS IN THE PREVENTION OF INTRAPERITONEAL ADHESIONS
    GAUWERKY, JFH
    MANN, J
    BASTERT, G
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1990, 247 (04) : 161 - 166
  • [27] Human vital amniotic membrane reduces adhesions in experimental intraperitoneal onlay mesh repair
    Petter-Puchner, A. H.
    Fortelny, R. H.
    Mika, K.
    Hennerbichler, S.
    Redl, H.
    Gabriel, C.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (07): : 2125 - 2131
  • [28] Human vital amniotic membrane reduces adhesions in experimental intraperitoneal onlay mesh repair
    A. H. Petter-Puchner
    R. H. Fortelny
    K. Mika
    S. Hennerbichler
    H. Redl
    C. Gabriel
    Surgical Endoscopy, 2011, 25 : 2125 - 2131
  • [29] Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study
    Villalobos, R. N.
    Mias, M. C.
    Gas, C.
    Maestre, Y.
    Nogues, M.
    Vilardell, F.
    Olsina, J. J.
    HERNIA, 2019, 23 (06) : 1123 - 1132
  • [30] Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study
    R. N. Villalobos
    M. C. Mias
    C. Gas
    Y. Maestre
    M. Nogués
    F. Vilardell
    J. J. Olsina
    Hernia, 2019, 23 : 1123 - 1132