Feasibility study of small animal imaging using clinical PET/CT scanner

被引:3
|
作者
Hsu, Wen-Lin [1 ]
Chen, Chia-Lin
Wang, Ze-Jing
Wu, Tung-Hsin
Liu, Dai-Wei
Lee, Jason J. S.
机构
[1] Tzu Chi Univ, Dept Radiol, Hualien, Taiwan
[2] Buddhist Tzu Chi Gen Hosp, Dept Radiat Oncol, Hualien, Taiwan
[3] Natl Yang Ming Univ, Fac Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
[4] Chung Shan Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
关键词
MicroPET; PET/CT; small animal imaging; spatial resolution;
D O I
10.1016/j.nima.2006.10.134
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The feasibility of small animal imaging using a clinical positron emission tomography/computed tomography (PET/CT) scanner with [F-18]-fluoro-2-deoxy-D-glucose (FDG) was evaluated. Two protocols in PET/CT system, single-mouse high-resolution mode (SHR) and multi-mouse high throughput mode (MHT) protocol were employed to investigate the ability of the scanner and also explored the performance differences between microPET and clinical PET/CT. In this study, we have found that even the clinical PET/CT scanner could not compete with the microPET scanner, especially in spatial resolution; the high-resolution CT image could advance the anatomical information to sub-millimeter level. Besides, CT-based attenuation correction can improve the image uniformity characteristics and quantification accuracy, and the large bore of a human whole-body scanner broadens the possibility of high throughput studies. Considering all the benefits, clinical PET/CT imaging might be a potential alternative for small animal study. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 50 条
  • [41] Imaging performance of A-PET, a GSO small animal 3-D PET scanner.
    Perkins, AE
    Surti, S
    Karp, JS
    Muehllehner, G
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 9P - 9P
  • [42] High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging
    Izumi O. Umeda
    Kotaro Tani
    Keisuke Tsuda
    Masamitsu Kobayashi
    Mayumi Ogata
    Sadaaki Kimura
    Mitsuyoshi Yoshimoto
    Shuji Kojima
    Kunikazu Moribe
    Keiji Yamamoto
    Noriyuki Moriyama
    Hirofumi Fujii
    Annals of Nuclear Medicine, 2012, 26 : 67 - 76
  • [43] High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging
    Umeda, Izumi O.
    Tani, Kotaro
    Tsuda, Keisuke
    Kobayashi, Masamitsu
    Ogata, Mayumi
    Kimura, Sadaaki
    Yoshimoto, Mitsuyoshi
    Kojima, Shuji
    Moribe, Kunikazu
    Yamamoto, Keiji
    Moriyama, Noriyuki
    Fujii, Hirofumi
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (01) : 67 - 76
  • [44] Characterization of a novel dual-panel PET scanner for use in small animal imaging
    Souris, JS
    Cho, S
    Penney, BC
    Chen, CT
    Kao, CM
    MEDICAL PHYSICS, 2005, 32 (06) : 2133 - 2133
  • [45] An MR compatible PET scanner based on RatCAP for small animal imaging at 9.4 T
    Maramraju, S. H.
    Junnarkar, S.
    Ravindranath, B.
    Southekal, S.
    Stoll, S.
    Smith, S. D.
    Lenz, W.
    Pratte, J. -F.
    Purschke, M.
    Rescia, S.
    Krishnamoorthy, S.
    Vaska, P.
    Woody, C.
    Schlyer, D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2954 - +
  • [46] New PET scanner for small animal imaging based on innovative straw detector technology
    Lacy, Jeffrey
    Sun, Liang
    Athanasiades, Athanasios
    Martin, Chris
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [47] Optimizing super-resolution on a clinical PET/CT for small animal PET
    DiFilippo, Frank
    Patel, Sagar
    Asosingh, Kewal
    Erzurum, Serpil
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [48] Small animal imaging with attenuation correction using clinical SPECT/CT scanners
    Boutchko, Rostyslav
    Balakrishnan, Karthikayan
    Reutter, Bryan W.
    Sauve, Anne
    Gullberg, Grant T.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4294 - 4295
  • [49] Design of a dual-modality, digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging
    Fontaine, R
    Michaud, JB
    Bélanger, F
    Cadorette, J
    Leroux, JD
    Pratte, JF
    Robert, S
    Lecomte, R
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 998 - 1001
  • [50] Small animal PET imaging
    Hutchins, Gary D.
    Miller, Michael A.
    Soon, Victor C.
    Receveur, Timothy
    ILAR JOURNAL, 2008, 49 (01) : 54 - 65