In recent years, the Monte Carlo (MC) methods have become an extensive and reference tool for criticality calculations. Despite the high precision that could be reached in MC modeling, the criticality calculations are still faced with the problem of fission source convergence leading, thereby, in some cases to false convergences and, in particular, to an erroneous effective multiplication factor. This is a challenging issue from a criticality safety point of view. Thus, to prevent from these specific issues and to obtain correct results, a convergence assessment has been carried out, for the first time, in this work, to the MC model of the NUR research reactor initial core. To this end, both effective multiplication factor (k(eff)) and Shannon entropy of the fission source (H-src) were evaluated for various M, the number of neutrons per cycle, and for different locations of the initial fission source in the reactor core. From the obtained results, it reveals that: a number of 10000 neutrons/cycles (or more) are needed to reduce bias on k(eff) and at least 30 inactive cycles arc required to allow k(eff) convergence. Whereas, the choice of a point source in each fuel element or in each fuel plate are the most preferred assumptions. As for the number of active cycles, it can be fixed according to the reasonable uncertainty that a user may accept for the effective multiplication factor, k(eff).
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Advantages of mesh tallying in MCNP5 for soil analysis calculations
    O. Doron
    L. Wielopolski
    S. Biegalski
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 183 - 186
  • [32] ESTIMATION OF DOSES RECEIVED BY OPERATORS IN THE 1958 RB REACTOR ACCIDENT USING THE MCNP5 COMPUTER CODE SIMULATION
    Pesic, Milan P.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (03): : 199 - 221
  • [33] Characteristics of multiprocessing MCNP5 on small personal computer clusters
    Robinson, S. M.
    McConn, R. J., Jr.
    Pagh, R. T.
    Schweppe, J. E.
    Siciliano, E. R.
    JOURNAL OF INSTRUMENTATION, 2006, 1
  • [34] Simulation of a new neutron calibration laboratory in Brazil using MCNP5
    Morero, Lucas Dadalt
    Pereira, Walsan Wagner
    Borges, Jose Carlos
    Nicolucci, Patricia
    APPLIED RADIATION AND ISOTOPES, 2022, 186
  • [35] MCNP5 modelling of HPGe detectors for efficiency evaluation in -ray spectrometry
    Maurotto, A.
    Rizzo, S.
    Tomarchio, E.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2009, 164 (5-6): : 302 - 306
  • [36] A COMPARISON OF BETA SKIN DOSES CALCULATED WITH VARSKIN 5.35.3 AND MCNP5
    Dubeau, J.
    Witharana, S. S. Hakmana
    Sun, J.
    Heinmiller, B. E.
    Chase, W. J.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 502 - 507
  • [37] APPLICATION OF MCNP5 SOFTWARE FOR EFFICIENCY CALCULATION OF A WHOLE BODY COUNTER
    Krstic, Dragana
    Cuknic, Olivera
    Nikezic, Dragoslav
    HEALTH PHYSICS, 2012, 102 (06): : 657 - 663
  • [38] Monte Carlo (MCNP5) Dose Calculation for Eye Plaque Therapy
    Palaniswaamy, G.
    Rangaraj, D.
    Yaddanapudi, S.
    Loyalka, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [39] Image enhancement using MCNP5 code and MATLAB in neutron radiography
    Tharwat, Montaser
    Mohamed, Nader
    Mongy, T.
    APPLIED RADIATION AND ISOTOPES, 2014, 89 : 30 - 36
  • [40] Flux and Dose Rate Evaluation of Iter System Using MCNP5
    Araujo, Arione
    Pereira, Claubia
    Fortini Veloso, Maria Auxiliadora
    Costa, Antonella Lombardi
    Dalle, Hugo Moura
    BRAZILIAN JOURNAL OF PHYSICS, 2010, 40 (01) : 58 - 62