机构:
Pfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Foley, David A.
[1
]
Bez, Eckhard
论文数: 0引用数: 0
h-index: 0
机构:
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Bez, Eckhard
[2
]
Codina, Anna
论文数: 0引用数: 0
h-index: 0
机构:
Bruker UK Ltd, Coventry CV4 9GH, W Midlands, EnglandPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Codina, Anna
[3
]
Colson, Kimberly L.
论文数: 0引用数: 0
h-index: 0
机构:
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Colson, Kimberly L.
[2
]
Fey, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Fey, Michael
[2
]
Krull, Robert
论文数: 0引用数: 0
h-index: 0
机构:
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Krull, Robert
[2
]
Piroli, Don
论文数: 0引用数: 0
h-index: 0
机构:
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Piroli, Don
[2
]
Zell, Mark T.
论文数: 0引用数: 0
h-index: 0
机构:
Pfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Zell, Mark T.
[1
]
Marquez, Brian L.
论文数: 0引用数: 0
h-index: 0
机构:
Pfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Bruker BioSpin, Billerica, MA 01821 USAPfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
Marquez, Brian L.
[1
,2
]
机构:
[1] Pfizer Worldwide Res & Dev, Analyt Res & Dev, Groton, CT 06340 USA
[2] Bruker BioSpin, Billerica, MA 01821 USA
[3] Bruker UK Ltd, Coventry CV4 9GH, W Midlands, England
In this paper we describe the development of a 5 mm NMR flow tube that can be used in a standard 5 mm NMR probe, enabling the user to conduct experiments on flowing samples or, more specifically, on flowing reaction mixtures. This enables reaction monitoring or kinetic experiments to be conducted by flowing reaction mixtures from a reaction vessel to detection in the coil area of the NMR, without the need for a specialized flow NMR probe. One of the key benefits of this flow tube is that it provides flexibility to be used across a range of available spectrometers of varying magnetic field strengths with a standard 5 mm probe setup. The applicability of this flow tube to reaction monitoring is demonstrated using the reaction of p-phenylenediamine and isobutyraldehyde to form the diimine product.
机构:Cent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, India
Grover, RK
Joshi, BS
论文数: 0引用数: 0
h-index: 0
机构:Cent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, India
Joshi, BS
Batra, S
论文数: 0引用数: 0
h-index: 0
机构:Cent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, India
Batra, S
Roy, R
论文数: 0引用数: 0
h-index: 0
机构:
Cent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, IndiaCent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, India
Roy, R
Bhaduri, AP
论文数: 0引用数: 0
h-index: 0
机构:Cent Drug Res Inst, Div RSIC, NMR Lab, Lucknow 226001, Uttar Pradesh, India