Toward Efficient Low-Temperature Ozone Gas Sterilization of Medical Devices

被引:15
|
作者
Thill, Sandy A. [1 ]
Spaltenstein, Marc [1 ]
机构
[1] SteriLux SA, Chemin Viaduc 12, CH-1008 Prilly, Switzerland
关键词
Ozone; sterilization; heat-sensitive medical devices; optical ozone measurement system; V-UV radiation to generate ozone; BACILLUS-SUBTILIS; SPORICIDAL ACTIVITY; INACTIVATION; HUMIDITY; SPORES;
D O I
10.1080/01919512.2019.1704217
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An ozone generation system using V-UV excimer lamps (172nm) and an optical measurement system based on the Beer-Lambert law were developed for an efficient low-temperature (15 degrees C-30 degrees C) sterilization of medical devices. Ozone concentrations between 100 and 1MODIFIER LETTER PRIME000 ppm (0.2-2 g/Nm(3)) were generated and the impact of several variables on the sterilization outcome were studied. The survivor curves of the sterilization process were obtained for biological indicators (BIs) inoculated with Geobacillus stearothermophilus spores. A lag phase was observed before the start of the actual sterilization which followed first-order log-linear kinetics. The results demonstrated the feasibility to sterilize medical devices with ozone at ambient temperatures, reducing the consumption of resources and the cost of sterilization.
引用
收藏
页码:386 / 398
页数:13
相关论文
共 50 条
  • [31] Comparative evaluation of the microbicidal activity of low-temperature sterilization technologies to steam sterilization
    Rutala, William A.
    Gergen, Maria F.
    Sickbert-Bennett, Emily E.
    Weber, David J.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 (04): : 391 - 395
  • [32] EVALUATION OF LOW-TEMPERATURE STERILIZATION OF TRICHINAE INFECTED PORK
    SMITH, HJ
    CANADIAN JOURNAL OF COMPARATIVE MEDICINE-REVUE CANADIENNE DE MEDECINE COMPAREE, 1975, 39 (03): : 316 - 320
  • [33] A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization
    Kanemitsu, K
    Imasaka, T
    Ishikawa, S
    Kunishima, H
    Harigae, H
    Ueno, K
    Takemura, H
    Hirayama, Y
    Kaku, M
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2005, 26 (05): : 486 - 489
  • [34] Simple filtration and low-temperature sterilization of drinking water
    Nimbkar, Nandini
    Rajvanshi, Anil K.
    CURRENT SCIENCE, 2013, 104 (04): : 519 - 522
  • [35] Sterilization by low-temperature atmospheric-pressure plasma
    Dzimitrowicz, Anna
    Jamroz, Piotr
    Nowak, Piotr
    POSTEPY MIKROBIOLOGII, 2015, 54 (02): : 195 - 200
  • [36] Characterization of Bacillus subtilis spore inactivation in low-pressure, low-temperature gas plasma sterilization processes
    Roth, S.
    Feichtinger, J.
    Hertel, C.
    JOURNAL OF APPLIED MICROBIOLOGY, 2010, 108 (02) : 521 - 531
  • [37] SEARCH FOR EFFICIENT CATALYSTS OF THE LOW-TEMPERATURE OZONE-CATALYTIC INTENSIVE OXIDATION OF HYDROCARBONS
    VOLFSON, VY
    SOLOVEV, SA
    SUDAK, AF
    VLASENKO, VM
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1984, 57 (08): : 1686 - 1691
  • [38] LOW-TEMPERATURE DECOMPOSITION OF OZONE BY FIBROUS CARBON
    RAKITSKAYA, TL
    BANDURKO, AY
    LITVINSKAYA, VV
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1993, 66 (09) : 1640 - 1642
  • [39] A LOW-TEMPERATURE ENERGY-EFFICIENT ACID GAS REMOVAL PROCESS
    HISE, RE
    MASSEY, LG
    ADLER, RJ
    BROSILOW, CB
    GARDNER, NC
    AUYANG, L
    BROWN, WR
    COOK, WJ
    LIU, YC
    ACS SYMPOSIUM SERIES, 1983, 223 : 27 - 45
  • [40] Low-temperature formation of Si oxide film by using silicone oil and ozone gas
    Toriyabe, K.
    Nishioka, K.
    Horita, S.
    IDW '06: PROCEEDINGS OF THE 13TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2006, : 719 - 722