Endoscopic treatment of native lung hyperinflation using endobronchial valves in single-lung transplant patients: a multinational experience

被引:16
|
作者
Perch, Michael [1 ]
Riise, Gerdt C. [2 ]
Hogarth, Kyle [3 ]
Musani, Ali I. [4 ]
Springmeyer, Steven C. [5 ]
Gonzalez, Xavier [5 ]
Iversen, Martin [1 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, Sect Lung Transplantat, DK-2100 Copenhagen, Denmark
[2] Univ Chicago, Chicago, IL 60637 USA
[3] Sahlgrens Univ Hosp, Gothenburg, Sweden
[4] Univ Colorado, Denver, CO 80202 USA
[5] Spiration Inc, Redmond, WA USA
来源
CLINICAL RESPIRATORY JOURNAL | 2015年 / 9卷 / 01期
关键词
COPD; emphysema; endobronchial valves; lung transplantation; native lung hyperinflation; VOLUME REDUCTION SURGERY; EMPHYSEMA; DYSFUNCTION; RECIPIENT;
D O I
10.1111/crj.12116
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BackgroundHyperinflation of the native lung (NLH) is a known complication to single-lung transplantation for emphysema. The hyperinflation can lead to compression of the graft and cause respiratory failure. Endobronchial valves have been used to block airflow in specific parts of the native lung, reducing the native lung volume and relieving the graft. ObjectiveWe report short-term follow-up and safety from 14 single-lung transplant patients with NLH treated with bronchoscopic lung volume reduction using endobronchial valves. MethodsRetrospective clinical information related to endobronchial valve treatment was obtained from four centres. All patients were treated with IBVTM Valve System (Spiration, Olympus Respiratory America, Redmond, WA, USA). All patients had evidence of severe NLH with mediastinal displacement. ResultsA total of 74 IBV valves were placed in 14 patients, with an average of 5.3 (range 2-10). Five patients had two procedures with staged treatment. Eleven patients reported symptom relief, and nine had lung function improvements. There was a significant increase in forced expiratory volume in 1s of 9% (P=0.013) and forced vital capacity of 15% (P=0.034) within the first months after treatment. There were no reported device-related adverse events nor reports of migration. Two patients had pneumothorax. One patient had pneumonia in the location of the valve placement, and another had infection within days. Three other patients were hospitalised with infection 2 months after treatment. ConclusionsTreating NLH with IBV endobronchial valves leads to clinical improvement in the majority of patients, and the treatment has an acceptable safety.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [41] A SINGLE-CENTER RETROSPECTIVE EVALUATION OF ENDOBRONCHIAL VALVES FOR LUNG VOLUME REDUCTION IN EMPHYSEMA PATIENTS
    Tseng, Steve
    Vick, Leigha
    Sue, Richard
    Alalawi, Raed
    CHEST, 2019, 156 (04) : 1779A - 1779A
  • [42] Split-lung volumetry in patients after single-lung transplantation using helium-MRI
    Markstaller, K
    Eberle, B
    Kauczor, HU
    Lill, J
    Puderbach, M
    Weller, N
    ANESTHESIOLOGY, 2000, : U11 - U11
  • [43] A single-center experience of 1500 lung transplant patients
    Balsara, Keki R.
    Krupnick, Alexander S.
    Bell, Jennifer M.
    Khiabani, Ali
    Scavuzzo, Masina
    Hachem, Ramsey
    Trulock, Elbert
    Witt, Chad
    Byers, Derek E.
    Yusen, Roger
    Meyers, Bryan
    Kozower, Benjamin
    Patterson, G. Alexander
    Puri, Varun
    Kreisel, Daniel
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02): : 894 - +
  • [44] Effect of Mycetoma in Lung Transplant Patients - a Single Center Experience
    Singh, Supriya
    Lum, Jessica
    Majeed, Aneela
    TRANSPLANTATION PROCEEDINGS, 2023, 55 (09) : 2197 - 2202
  • [45] AIR-EMBOLISM IN SINGLE-LUNG TRANSPLANT PATIENTS AFTER CENTRAL VENOUS CATHETER REMOVAL
    MCCARTHY, PM
    WANG, N
    BIRCHFIELD, F
    MEHTA, AC
    CHEST, 1995, 107 (04) : 1178 - 1179
  • [46] Single-lung ventilation in a critically ill patient using a fiberoptically directed wire-guided endobronchial blocker
    Arndt, GA
    Kranner, PW
    Rusy, DA
    Love, R
    ANESTHESIOLOGY, 1999, 90 (05) : 1484 - 1486
  • [47] Biofilm infections of endobronchial valves in COPD patients after endoscopic lung volume reduction: a pilot study with FISHseq
    Pappe, Eva
    Huebner, Ralf-Harto
    Saccomanno, Jacopo
    Ebrahimi, Hadis Darvishi Nakhl
    Witzenrath, Martin
    Wiessner, Alexandra
    Sarbandi, Kurosh
    Xiong, Zhile
    Kursawe, Laura
    Moter, Annette
    Kikhney, Judith
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [48] Lung Volume Reduction Using Endobronchial Valves In COPD Patients With Low Emphysema Heterogeneity Scores
    Herth, F. J.
    Gompelmann, D.
    Criner, G. J.
    Sciurba, F. C.
    Ernst, A.
    Eberhardt, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [49] Quantitative Evaluation of Native Transplantation for Emphysema Tomography Volumetry Lung Hyperinflation After Single Lung Using Three-Dimensional Computed
    Motoyama, H.
    Chen, F.
    Ohsumi, A.
    Hijiya, K.
    Takahashi, M.
    Ohata, K.
    Yamada, T.
    Sato, M.
    Aoyama, A.
    Bando, T.
    Date, H.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 941 - 943
  • [50] Reversal of collateral ventilation using endoscopic polymer foam in COPD patients undergoing endoscopic lung volume reduction with endobronchial valves: A controlled parallel group trial
    Ing, A.
    Jayapadman, A.
    Kim, W.
    Ly, C.
    Ho-Shon, K.
    Lilburn, P.
    Carew, A.
    Ng, B.
    Saghaie, T.
    Williamson, J.
    RESPIROLOGY, 2023, 28 : 94 - 94