Endoscopic treatment of native lung hyperinflation using endobronchial valves in single-lung transplant patients: a multinational experience

被引:16
|
作者
Perch, Michael [1 ]
Riise, Gerdt C. [2 ]
Hogarth, Kyle [3 ]
Musani, Ali I. [4 ]
Springmeyer, Steven C. [5 ]
Gonzalez, Xavier [5 ]
Iversen, Martin [1 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, Sect Lung Transplantat, DK-2100 Copenhagen, Denmark
[2] Univ Chicago, Chicago, IL 60637 USA
[3] Sahlgrens Univ Hosp, Gothenburg, Sweden
[4] Univ Colorado, Denver, CO 80202 USA
[5] Spiration Inc, Redmond, WA USA
来源
CLINICAL RESPIRATORY JOURNAL | 2015年 / 9卷 / 01期
关键词
COPD; emphysema; endobronchial valves; lung transplantation; native lung hyperinflation; VOLUME REDUCTION SURGERY; EMPHYSEMA; DYSFUNCTION; RECIPIENT;
D O I
10.1111/crj.12116
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BackgroundHyperinflation of the native lung (NLH) is a known complication to single-lung transplantation for emphysema. The hyperinflation can lead to compression of the graft and cause respiratory failure. Endobronchial valves have been used to block airflow in specific parts of the native lung, reducing the native lung volume and relieving the graft. ObjectiveWe report short-term follow-up and safety from 14 single-lung transplant patients with NLH treated with bronchoscopic lung volume reduction using endobronchial valves. MethodsRetrospective clinical information related to endobronchial valve treatment was obtained from four centres. All patients were treated with IBVTM Valve System (Spiration, Olympus Respiratory America, Redmond, WA, USA). All patients had evidence of severe NLH with mediastinal displacement. ResultsA total of 74 IBV valves were placed in 14 patients, with an average of 5.3 (range 2-10). Five patients had two procedures with staged treatment. Eleven patients reported symptom relief, and nine had lung function improvements. There was a significant increase in forced expiratory volume in 1s of 9% (P=0.013) and forced vital capacity of 15% (P=0.034) within the first months after treatment. There were no reported device-related adverse events nor reports of migration. Two patients had pneumothorax. One patient had pneumonia in the location of the valve placement, and another had infection within days. Three other patients were hospitalised with infection 2 months after treatment. ConclusionsTreating NLH with IBV endobronchial valves leads to clinical improvement in the majority of patients, and the treatment has an acceptable safety.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [1] Endoscopic Treatment of Native Lung Hyperinflation with One-Way Valves in Single Lung Transplant Patients: A Multinational Experience
    Perch, M.
    Hogarth, D. K.
    Springmeyer, S. C.
    Riise, G. C.
    Musani, A. L.
    Gonzalez, X.
    Iversen, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S248 - S249
  • [2] Endobronchial Valve Treatment for Native Lung Hyperinflation in a Single-Lung Transplant Patient
    Amja, J. J.
    Khan, A. N.
    Goyal, A.
    Dilling, D. F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [3] Use of endobronchial valves for native lung hyperinflation respiratory failure associated with in a single-lung transplant recipient for emphysema
    Crespo, Maria M.
    Johnson, Bruce A.
    McCurry, Kenneth R.
    Landreneau, Rodney J.
    Sciurba, Frank C.
    CHEST, 2007, 131 (01) : 214 - 216
  • [4] OUTCOME OF THE NATIVE LUNG AFTER SINGLE-LUNG TRANSPLANT
    FROST, AE
    KELLER, CA
    NOON, GP
    SHORT, HD
    CAGLE, PT
    CHEST, 1995, 107 (04) : 981 - 984
  • [5] OUTCOME OF THE NATIVE LUNG FOLLOWING SINGLE-LUNG TRANSPLANT
    FROST, AE
    KELLER, CK
    NOON, GP
    SHORT, HD
    CAGLE, PT
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A599 - A599
  • [6] Lung volume reduction surgery for native lung hyperinflation following single-lung transplantation for emphysema: which patients?
    Wilson, Henrietta
    Carby, Martin
    Beddow, Emma
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (03) : 410 - 413
  • [7] Impact of Native Lung Pneumonectomy in Single-Lung Transplant Recipients
    Rusanov, V.
    Rosengarten, D.
    Fox, B.
    Medalion, B.
    Saute, M.
    Kramer, M. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S310 - S311
  • [8] Endoscopic Lung Volume Reduction (elvr) With One-Way Valves For The Treatment Of Late Post-Transplant Hyperinflation Of The Native Lung
    Sienra, R. A. T.
    Pedrao, N. B.
    Cardoso, P. F. G.
    Fernandes, L.
    Abdalla, L. G.
    Samano, M.
    Pego-Fernandes, P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [9] Bronchoscopic Lung Volume Reduction in a Single-Lung Transplant Recipient With Natal Lung Hyperinflation: A Case Report
    Pato, O.
    Rama, P.
    Allegue, M.
    Fernandez, R.
    Gonzalez, D.
    Borro, J. M.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (05) : 1979 - 1981
  • [10] Native Lung Complications in Single-lung Transplant Recipients and the Role of Pneumonectomy
    King, Christopher S.
    Khandhar, Sandeep
    Burton, Nelson
    Shlobin, Oksana A.
    Ahmad, Shahzad
    Lefrak, Edward
    Barnett, Scott D.
    Nathan, Steven D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (08): : 851 - 856