Evaluation of ocular biometry in primary angle-closure disease with two swept source optical coherence tomography devices

被引:7
|
作者
Wanichwecharungruang, Boonsong [1 ,2 ,3 ]
Amornpetchsathaporn, Anyarak [1 ,2 ]
Wongwijitsook, Wisakorn [1 ,2 ]
Kongsomboon, Kittipong [4 ]
Chantra, Somporn [1 ,2 ]
机构
[1] Rajavithi Hosp, Dept Ophthalmol, Bangkok, Thailand
[2] Rangsit Med Coll, Bangkok, Thailand
[3] Priest Hosp, Dept Ophthalmol, Bangkok, Thailand
[4] Srinakharinwirot Univ, Fac Med, Dept Prevent & Social Med, Nakhon Nayok, Thailand
来源
PLOS ONE | 2022年 / 17卷 / 03期
关键词
INTRAOCULAR-LENS POWER; PERIPHERAL IRIDOTOMY; GLAUCOMA; PHACOEMULSIFICATION; PREVALENCE; OUTCOMES;
D O I
10.1371/journal.pone.0265844
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeTo investigate agreement between 2 swept source OCT biometers, IOL Master700 and Anterion, in various ocular biometry and intraocular lens (IOL) calculations of primary angle-closure disease (PACD). SettingRajavithi Hospital, Bangkok, Thailand. DesignProspective comparative study. MethodsThis study conducted in a tertiary eye care center involving biometric measurements obtained with 2 devices in phakic eye with diagnosis of PACD. Mean difference and intraclass correlation coefficient (ICC) with confidence limits were assessed, and calculations of estimated residual refraction of the IOL were analysed using Barrett's formula. ResultsSixty-nine eyes from 45 PACD patients were enrolled for the study. Excellent agreement of various parameters was revealed, with ICC (confidence limits) of K1 = 0.953 (0.861-0.979), K2 = 0.950 (0.778-0.98), ACD = 0.932 (0.529-0.978), WTW = 0.775 (0.477-0.888), and LT = 0.947 (0.905-0.97). Mean difference of axial length (AL) was -0.01 +/- 0.02 mm with ICC of 1.000. IOL calculation was assessed with Barrett's formula, and Bland-Altman plot showed excellent agreement in the results of the 2 devices for the IOL power and estimated post-operative residual refraction (EPR). ConclusionsMean differences of biometric parameters, obtained with IOL Master700 and Anterion, were small, and ICC showed excellent concordance. No clinical relevance in calculation of IOL power was found, and the two devices appeared to be comparably effective in clinical practice.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Correction: Evaluation of Schlemm’s canal with swept-source optical coherence tomography in primary angle-closure disease
    Xuming Ding
    Lulu Huang
    Cheng Peng
    Li Xu
    Yixin Liu
    Yijie Yang
    Ning Wang
    Mengyang Gu
    Chengyang Sun
    Yue Wu
    Wenyi Guo
    BMC Ophthalmology, 23
  • [2] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [3] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    ANNALS OF EYE SCIENCE, 2023, 8
  • [4] Ocular Biometry of Primary Angle-Closure Disease in Younger Patients
    Lin, Shufen
    Zuo, Chengguo
    Liu, Yuan
    Xiao, Hui
    Fang, Lei
    Su, Yihua
    Chen, Liming
    Lin, Mingkai
    Ling, Yunlan
    Liu, Xing
    FRONTIERS IN MEDICINE, 2021, 8
  • [5] Evaluation of Schlemm's canal with swept-source optical coherence tomography in primary angle-closure disease (vol 23, 256, 2023)
    Ding, Xuming
    Huang, Lulu
    Peng, Cheng
    Xu, Li
    Liu, Yixin
    Yang, Yijie
    Wang, Ning
    Gu, Mengyang
    Sun, Chengyang
    Wu, Yue
    Guo, Wenyi
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [6] Ocular Biometry in Primary Angle-closure Glaucoma
    Lan, Yu-Wen
    Hsieh, Jui-Wen
    Hung, Por-Tying
    JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (04) : 243 - 250
  • [7] The anterior and posterior biometric characteristics in primary angle-closure disease: Data based on anterior segment optical coherence tomography and swept-source optical coherence tomography
    Huang, Wenbin
    Li, Xingyi
    Gao, Xinbo
    Zhang, Xiulan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (04) : 865 - 870
  • [8] Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease
    Ma, Ping
    Wu, Yanyan
    Oatts, Julius
    Patlidanon, Jutima
    Yu, Yinxi
    Ying, Gui-Shuang
    Kline, Brad
    Tun, Tin A.
    He, Mingguang
    Aung, Tin
    Li, Shuning
    Yang, Yangfan
    Han, Ying
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 68 - 77
  • [9] Assessment of Circumferential Angle-Closure by the IriseTrabecular Contact Index with Swept-Source Optical Coherence Tomography
    Baskaran, Mani
    Ho, Sue-Wei
    Tun, Tin A.
    How, Alicia C.
    Perera, Shamira A.
    Friedman, David S.
    Aung, Tin
    OPHTHALMOLOGY, 2013, 120 (11) : 2226 - 2231
  • [10] Comparison of Two Spectral Domain Optical Coherence Tomography Devices for Angle-Closure Assessment
    Quek, Desmond T.
    Narayanaswamy, Arun K.
    Tun, Tin A.
    Htoon, Hla M.
    Baskaran, Mani
    Perera, Shamira A.
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (09) : 5131 - 5136