The Auger electron effect in radiation dosimetry - A review

被引:0
|
作者
Persson, L
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radionuclides that emit Auger electrons are widely used in nuclear medicine and biomedical research. The Auger emitting radionuclides give off a cascade of low energy electrons, the total energy of which is deposited within some nanometers; the local dose is therefore very high. If the radionuclide is part of a chemical compund which forms a DNA base analogue or which preferentially enters the cell nucleus, the biological effects of the Auger electrons to the DNA or the nucleus can be as severe as from high-LET alpha particles. Neither the recommendations of the International Commission on Radiological Protection (ICRP) in Publication No. 60, nor the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources provide any guidance on calculating the equivalent dose for these radionuclides. For the radiation weighting factor of electrons (value 1) they recommend excluding the Auger electrons emitted from nuclei bound to DNA. However, recently a Task Group of the American Association of Physicists in Medicine (AAPM) has proposed that the component of dose from the Auger electrons for radionuclides bound to DNA be given a preliminary radiation weighting factor of of 10 for deterministic effects and 20 for stochastic effects. The dose equivalent calculated with these weighting factors must be modulated by experimentally determined subcellular distributions.
引用
收藏
页码:B511 / B513
页数:3
相关论文
共 50 条
  • [31] Evidence of the stent effect on radiation dosimetry.
    Duckworth, T
    Chiu-Tsao, ST
    Patel, N
    Fan, P
    Quon, H
    Ravi, K
    Sherman, W
    Pisch, J
    Harrison, L
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 124I - 124I
  • [32] Mannitol as a radiation sensitive material for electron paramagnetic resonance dosimetry
    Karakirova, Y.
    Yordanov, N.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2015, 47 (01): : 144 - 148
  • [33] Bone powder as EPR dosimetry system for electron and gamma radiation
    Ziaie, Farhood
    Hajiloo, Nahid
    Fathollahi, Hadi
    Mehtieva, Salima I.
    NUKLEONIKA, 2009, 54 (04) : 267 - 270
  • [34] Radiation dosimetry in human bone using electron paramagnetic resonance
    Breen, SL
    Battista, JJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2065 - 2077
  • [35] DESIGN AND DOSIMETRY OF AN ELECTRON APPLICATOR FOR INTEROPERATIVE RADIATION-THERAPY
    BORAK, TB
    SCOTT, RJ
    GILLETTE, EL
    MEDICAL PHYSICS, 1986, 13 (04) : 582 - 582
  • [36] PROGRESS ON STANDARDIZATION OF ELECTRON-BEAM DOSIMETRY FOR RADIATION PROCESSING
    LI, CH
    ZHANG, YL
    PANG, RC
    LIU, ZM
    XIA, X
    WU, JM
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 823 - 826
  • [37] Evaluation of Radiation Dosimetry of Bolus Electron Conformal Therapy (ECT)
    Toramatsu, C.
    Furuya, T.
    Sugimoto, S.
    Kitou, S.
    Kurokawa, C.
    Ozawa, S.
    Karasawa, K.
    Sasai, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [38] Radiation and the heart: systematic review of dosimetry and cardiac endpoints
    Niska, Joshua R.
    Thorpe, Cameron S.
    Allen, Sorcha M.
    Daniels, Thomas B.
    Rule, William G.
    Schild, Steven E.
    Vargas, Carlos E.
    Mookadam, Farouk
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2018, 16 (12) : 931 - 950
  • [39] AUGER ELECTRON SPECTROSCOPY IN SCANNING ELECTRON MICROSCOPE - AUGER ELECTRON IMAGES
    MACDONALD, NC
    WALDROP, JR
    APPLIED PHYSICS LETTERS, 1971, 19 (09) : 315 - +
  • [40] A Review: Photonic Devices Used for Dosimetry in Medical Radiation
    Damulira, Edrine
    Yusoff, Muhammad Nur Salihin
    Omar, Ahmad Fairuz
    Taib, Nur Hartini Mohd
    SENSORS, 2019, 19 (10)