Over the past decade, several computerized tools have been developed for detection of lung nodules and for providing volumetric analysis. Incidentally detected lung nodules have traditionally been followed over time by measurements of their axial dimensions on CT scans to ensure stability or document progression. A recently published article by the Fleischner Society offers guidelines on the management of incidentally detected nodules based on size criteria. For this reason, differences in measurements obtained by automated tools from various vendors may have significant implications on management, yet the degree of variability in these measurements is not well understood. The goal of this study is to quantify the differences in nodule maximum diameter and volume among different automated analysis software. Using a dataset of lung scans obtained with both "ultra-low" and conventional doses, we identified a subset of nodules in each of five size-based categories. Using automated analysis tools provided by three different vendors, we obtained size and volumetric measurements on these nodules, and compared these data using descriptive as well as ANOVA and t-test analysis. Results showed significant differences in nodule maximum diameter measurements among the various automated lung nodule analysis tools but no significant differences in nodule volume measurements. These data suggest that when using automated commercial software, volume measurements may be a more reliable marker of tumor progression than maximum diameter. The data also suggest that volumetric nodule measurements may be relatively reproducible among various commercial workstations, in contrast to the variability documented when performing human mark-ups, as is seen in the LIDC (lung imaging; database consortium) study.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Reproducibility and biologic variability of volumetric intravascular ultrasound measurements
    Shiran, A
    Mintz, GS
    Kimura, T
    Nobuyoshi, M
    Oljaca, B
    Kent, KM
    Pichard, AD
    Satler, LF
    Popma, JJ
    Leon, MB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 496A - 496A
  • [22] Pulmonary Nodules: Preliminary Experience with Semiautomated Volumetric Evaluation by CT Stratum
    Sone, Shusuke
    Tsushima, Kenji
    Yoshida, Kazuo
    Hamanaka, Kazutoshi
    Hanaoka, Takaomi
    Kondo, Ryoichi
    ACADEMIC RADIOLOGY, 2010, 17 (07) : 900 - 911
  • [23] Reproducibility of volumetric computed tomography (VCT) of stable calcified pulmonary nodules
    Smith, Gary
    Walker, Ronald
    Moore, Brandon
    Massion, Pierre
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [24] Detection of pulmonary nodules on CT and volumetric assessment of change over time
    Betke, M
    Ko, JP
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 245 - 252
  • [25] PULMONARY NODULES IN SPIRAL VOLUMETRIC AND SINGLE SLICE COMPUTED-TOMOGRAPHY
    FRIESE, SA
    RIEBER, A
    FLEITER, T
    BRAMBS, HJ
    CLAUSSEN, CD
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (01) : 48 - 51
  • [26] Volumetric growth index (VGI) for small pulmonary nodules: Development and validation
    Reeves, AP
    Yankelevitz, DF
    Kostis, WJ
    Henschke, CI
    RADIOLOGY, 2001, 221 : 311 - 312
  • [27] Imprecision in Automated Volume Measurements of Pulmonary Nodules and Its Effect on the Level of Uncertainty in Volume Doubling Time Estimation
    Nietert, Paul J.
    Ravenel, James G.
    Leue, William M.
    Miller, James V.
    Taylor, Katherine K.
    Garrett-Mayer, Elizabeth S.
    Silvestri, Gerard A.
    CHEST, 2009, 135 (06) : 1580 - 1587
  • [28] Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program
    Wang, Ying
    van Klaveren, Rob J.
    van der Zaag-Loonen, Hester J.
    de Bock, Geertruida H.
    Gietema, Hester A.
    Xu, Dong Ming
    Leusveld, Anne L. M.
    de Koning, Harry J.
    Scholten, Ernst T.
    Verschakelen, Johny
    Prokop, Mathias
    Oudkerk, Matthijs
    RADIOLOGY, 2008, 248 (02) : 625 - 631
  • [29] Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study
    Way, Ted W.
    Chan, Heang-Ping
    Goodsitt, Mitchell M.
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Zhou, Chuan
    Chughtai, Aamer
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (05): : 1295 - 1312
  • [30] AUTOMATED PULMONARY-FUNCTION MEASUREMENTS
    BLAIS, MR
    FANTON, JL
    HEWLETT-PACKARD JOURNAL, 1979, 30 (09): : 20 - 24