Volumetric measurements of pulmonary nodules: variability in automated analysis tools

被引:1
|
作者
Juluru, Krishna [1 ]
Kim, Woojin [1 ]
Boonn, William [1 ]
King, Tara [1 ]
Siddiqui, Khan [1 ]
Siegel, Eliot [1 ]
机构
[1] VA Maryland Healthcare, 10N Greene St,Radiol 114, Baltimore, MD 21201 USA
关键词
chest imaging; CT; lung nodule; automated measuring tools;
D O I
10.1117/12.711642
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Over the past decade, several computerized tools have been developed for detection of lung nodules and for providing volumetric analysis. Incidentally detected lung nodules have traditionally been followed over time by measurements of their axial dimensions on CT scans to ensure stability or document progression. A recently published article by the Fleischner Society offers guidelines on the management of incidentally detected nodules based on size criteria. For this reason, differences in measurements obtained by automated tools from various vendors may have significant implications on management, yet the degree of variability in these measurements is not well understood. The goal of this study is to quantify the differences in nodule maximum diameter and volume among different automated analysis software. Using a dataset of lung scans obtained with both "ultra-low" and conventional doses, we identified a subset of nodules in each of five size-based categories. Using automated analysis tools provided by three different vendors, we obtained size and volumetric measurements on these nodules, and compared these data using descriptive as well as ANOVA and t-test analysis. Results showed significant differences in nodule maximum diameter measurements among the various automated lung nodule analysis tools but no significant differences in nodule volume measurements. These data suggest that when using automated commercial software, volume measurements may be a more reliable marker of tumor progression than maximum diameter. The data also suggest that volumetric nodule measurements may be relatively reproducible among various commercial workstations, in contrast to the variability documented when performing human mark-ups, as is seen in the LIDC (lung imaging; database consortium) study.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules
    Milanese, Gianluca
    Eberhard, Matthias
    Martini, Katharina
    De Martini, Ilaria Vittoria
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 97 - 102
  • [2] Volumetric analysis for pulmonary nodules surveillance: a retrospective audit
    Rowan, C.
    Farmer, N.
    Exley, C.
    Ameri, A.
    LUNG CANCER, 2019, 127 : S12 - S12
  • [3] Automated metamorphic testing of variability analysis tools
    Segura, Sergio
    Duran, Amador
    Sanchez, Ana B.
    Le Berre, Daniel
    Lonca, Emmanuel
    Ruiz-Cortes, Antonio
    SOFTWARE TESTING VERIFICATION & RELIABILITY, 2015, 25 (02): : 138 - 163
  • [4] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Dag Wormanns
    Gerhard Kohl
    Ernst Klotz
    Anke Marheine
    Florian Beyer
    Walter Heindel
    Stefan Diederich
    European Radiology, 2004, 14 : 86 - 92
  • [5] Dynamic CT imaging of volumetric changes in pulmonary nodules correlates with physical measurements of stiffnes
    Lartey, Frederick M.
    Rafat, Marjan
    Negahdar, Mohammadreza
    Malkovskiy, Andrey V.
    Dong, Xinzhe
    Sun, Xiaoli
    Li, Mei
    Doyle, Timothy
    Rajadas, Jayakumar
    Graves, Edward E.
    Loo, Billy W.
    Maxim, Peter G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (02) : 313 - 318
  • [6] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Wormanns, D
    Kohl, G
    Klotz, E
    Marheine, A
    Beyer, F
    Heindel, W
    Diederich, S
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 86 - 92
  • [7] Automated volumetric analysis of four cardiac chambers in pulmonary embolism
    Aviram, Galit
    Sirota-Cohen, Chen
    Steinvil, Arie
    Keren, Gad
    Banai, Shmuel
    Sosna, Jacob
    Berliner, Shlomo
    Rogowski, Ori
    THROMBOSIS AND HAEMOSTASIS, 2012, 108 (02) : 384 - 393
  • [8] Automated volumetric segmentation method for growth consistency of nonsolid pulmonary nodules in high-resolution CT
    Browder, William A.
    Reeves, Anthony P.
    Apananosovich, Tatiyana V.
    Cham, Matthew D.
    Yankelevitz, David F.
    Henschke, Claudia I.
    MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [9] Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    Gietema, Hester A.
    Wang, Ying
    Xu, Dongming
    van Klaveren, Rob J.
    deKoning, Harry
    Scholten, Ernst
    Verschakelen, Johny
    Kohl, Gerhard
    Oudkerk, Matthijs
    Prokop, Mathias
    RADIOLOGY, 2006, 241 (01) : 251 - 257
  • [10] The utility of automated volumetric growth analysis in a dedicated pulmonary nodule clinic
    Korst, Robert J.
    Lee, Benjamin E.
    Krinsky, Glenn A.
    Rutledge, John R.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (02): : 372 - 377