Zinc Oxide Nanostructured-Based Sensors for Anodic Stripping Voltammetric Determination of Darifenacin

被引:8
|
作者
Al-Qahtani, Salhah D. [1 ]
Hameed, Ahmed [2 ]
Alamrani, Nasser A. [3 ]
Alharbi, Ahmed [2 ]
Shah, Reem [2 ]
Al-Ahmed, Zehbah A. [4 ]
El-Metwaly, Nashwa M. [2 ,5 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Dept Chem, Riyadh 11671, Saudi Arabia
[2] Umm Al Qura Univ, Fac Appl Sci, Dept Chem, Mecca, Saudi Arabia
[3] Univ Tabuk, Fac Sci, Dept Chem, Tabuk 71491, Saudi Arabia
[4] Dhahran Aljounb King Khalid Univ, Coll Sci & Art, Dept Chem, Riyadh, Saudi Arabia
[5] Mansoura Univ, Fac Sci, Dept Chem, Mansoura, Egypt
关键词
OVERACTIVE BLADDER; SPECTROPHOTOMETRIC METHODS; DEGRADATION-PRODUCTS; HYDROBROMIDE; BULK; NANOPARTICLES; VALIDATION; TARTRAZINE; STABILITY;
D O I
10.1149/1945-7111/ac77c2
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Herein for the first time, the construction and the electroanalytical applications of novel darifenacin (DFC) voltammetric sensors were described. Zinc oxide nanostructures act as a proper redox mediator and exhibit efficient catalytic activity towards the electrooxidation of the DFC molecule. At the optimum measuring conditions, DFC exhibited an irreversible anodic oxidation peak at 0.880 V with an assumed adsorption-reaction mechanism at the electrode surface. Based on the effect of the pH and the scan rate studies, electrooxidation of DFC takes place through the oxidation of the nitrogen atom (N12) in the five-membered ring of the darifenacin molecule with the participation of one electron and one proton in agreement with the molecular orbital calculations. Calibration curves were linear within the DFC concentration ranging from 0.33 to 6.54 x 10(-6) mol l(-1) with a limit of detection (LOD) and limit of quantification (LOQ) values of 0.08 and 0.23 x 10(-6) mol l(-1). The proposed sensors exhibited enhanced performance with high measurement reproducibility and prolonged lifetime. The presented voltammetric approach was utilized for precise determination of darifenacin in biological samples and pharmaceutical formulations with acceptable recoveries compared with the traditional spectrophotometric methods.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Determination of zinc in fuel alcohol by anodic stripping voltammetry
    de Oliveira, MF
    Saczk, AA
    Okumura, LL
    Stradiotto, NR
    ECLETICA QUIMICA, 2002, 27 : 153 - 160
  • [22] Anodic adsorptive stripping voltammetric determination of the anesthetic drug: methohexital sodium
    Farghaly, OA
    Abd El-Wadood, HM
    Ghandour, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (02) : 233 - 240
  • [23] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Zehra Yazar Aydın
    Yesim Tugce Yaman
    Merve Yaşacan
    Tamer Çırak
    Serdar Abacı
    Journal of the Iranian Chemical Society, 2017, 14 : 803 - 810
  • [24] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Aydin, Zehra Yazar
    Yaman, Yesim Tugce
    Yasacan, Merve
    Cirak, Tamer
    Abaci, Serdar
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (04) : 803 - 810
  • [25] Sono-anodic stripping voltammetric determination of cadmium in the presence of surfactant
    Y. C. Tsai
    J. Davis
    R. G. Compton
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 415 - 417
  • [26] Anodic stripping voltammetric assay for the determination of prazosin at carbon paste electrodes
    Arranz, A
    Moreda, JM
    Arranz, JF
    QUIMICA ANALITICA, 2000, 19 (01): : 31 - 37
  • [27] Sonoelectroanalysis: Anodic stripping voltammetric determination of cadmium in whole human blood
    Kruusma, J
    Nei, L
    Hardcastle, JL
    Compton, RG
    Lust, E
    Keis, H
    ELECTROANALYSIS, 2004, 16 (05) : 399 - 403
  • [28] Determination of Cr(VI) Content in Leather with Anodic Stripping Voltammetric Polargraphy
    Zhu Zhengxin
    An Xun
    Zhang Zongcai
    Dai Hong
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2011, 95 (06): : 255 - 258
  • [29] Sono-anodic stripping voltammetric determination of cadmium in the presence of surfactant
    Tsai, YC
    Davis, J
    Compton, RG
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 415 - 417
  • [30] Differential pulse anodic stripping voltammetric determination of ziram (a dithiocarbamate fungicide)
    Mathew, L
    Reddy, MLP
    Rao, TP
    Iyer, CSP
    Damodaran, AD
    TALANTA, 1996, 43 (01) : 73 - 76