Preliminary Clinical Validation of a Differential Correction Method for Improving Measurement Accuracy in Noninvasive Measurement of Blood Glucose Using Near-Infrared Spectroscopy

被引:14
|
作者
Han, Guang [1 ]
Yu, Xuyao [1 ]
Xia, Dandan [1 ]
Liu, Rong [1 ]
Liu, Jin [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Noninvasive blood glucose measurement; diffuse reflectance; floating-reference position; partial least squares; TISSUE;
D O I
10.1177/0003702816685335
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the main challenges in the noninvasive sensing of blood glucose by near-infrared (NIR) spectroscopy is the background variations from light source drift, sweating, and temperature change at the human-machine interface. In this paper, a differential correction method based on the spectra from the floating-reference position and measuring position is proposed to eliminate these spectral variations from background interferences. Its effectiveness was validated by invitro and invivo experiments in which the diffuse reflectance of intralipid solutions and human skin was collected at the source distances of 0.6mm and 2mm by the custom-built system with six super-luminescent emitting diodes (SLEDs) light source. The results showed that, for the invitro experiments of intralipid solutions, the coefficients of variations of diffuse reflectance decreased by 20.5% under all the six wavelengths after differential correction. For the invivo experiments of oral glucose tolerance tests (OGTTs), partial least squares (PLS) regression models between glucose concentrations and the diffuse reflectance from palm skin were built, and the root mean square error of cross validation (RMSECV) decreased by 38.0% on average after the differential correction. Further, the spectra of the oral water tolerance tests (OWTTs) were collected for correlation with glucose concentration in OGTTs, and their correlation coefficients (R) decreased by 35.0% on average after the differential correction. Therefore, this differential correction method based on the spectra from the floating-reference position and measuring position can weaken the influence of background variations on the NIR spectroscopy and has promising potential in invivo detection, especially for noninvasive blood glucose measurement.
引用
收藏
页码:2177 / 2186
页数:10
相关论文
共 50 条
  • [41] NONINVASIVE MEASUREMENT OF FOREARM BLOOD-FLOW AND OXYGEN-CONSUMPTION BY NEAR-INFRARED SPECTROSCOPY
    DEBLASI, RA
    FERRARI, M
    NATALI, A
    CONTI, G
    MEGA, A
    GASPARETTO, A
    JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (03) : 1388 - 1393
  • [42] NONINVASIVE MEASUREMENT OF FOREARM OXYGEN-CONSUMPTION BY NEAR-INFRARED SPECTROSCOPY
    CHEN, B
    AMORY, DW
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (04) : 1617 - 1618
  • [43] Noninvasive measurement of cerebral blood volume changes in schizophrenia: A multichannel near-infrared spectroscopy study
    Kameyama, M
    Yamagishi, Y
    Ito, M
    Suto, T
    Uehara, T
    Ida, I
    Fukuda, M
    Mikuni, M
    BIOLOGICAL PSYCHIATRY, 2003, 53 (08) : 55S - 55S
  • [44] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [45] NONINVASIVE IN-VIVO MEASUREMENT OF BLOOD SPECTRUM BY TIME-RESOLVED NEAR-INFRARED SPECTROSCOPY
    NAHM, W
    GEHRING, H
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) : 174 - 179
  • [46] Measurement and analysis of the glucose concentration of the whole blood using near-infrared spectrum
    Ding, Dong
    Zhang, Hong-Yan
    Wang, Li-Qiu
    Zhou, Wei-Dong
    Wang, Xi-Ming
    Shen, Xuan-Guo
    Jiguang Yu Hongwai/Laser and Infrared, 2003, 33 (05):
  • [47] Preliminary study of mechanism of non-invasive blood glucose measurement based on near-infrared diffuse reflectance spectroscopy
    Chen, WL
    Liu, R
    Luo, YH
    Han, YH
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 91 - 100
  • [48] Improved stability of blood glucose measurement in humans using near infrared spectroscopy
    So, C. F.
    Chung, Joanne W. Y.
    Siu, Maggie S. M.
    Wong, Thomas K. S.
    SPECTROSCOPY-BIOMEDICAL APPLICATIONS, 2011, 25 (3-4): : 137 - 145
  • [49] Cerebrovascular reactivity measurement using near-infrared spectroscopy
    Grosset, D
    CLINICAL SCIENCE, 1998, 95 (04) : 395 - 395
  • [50] Noninvasive blood glucose sensing with near-infrared spectroscopy based on interstitial fluid
    Lu, Q. (luqipeng@126.com), 1600, Chinese Optical Society (33):