Low-cost EDA device for screening diabetic neuropathy

被引:2
|
作者
Daniel Bolanos, Luis [1 ]
Maria Vicente-Samper, Jose [2 ]
Zambrana Vinaroz, David [2 ]
Andres Vivas, Oscar [1 ]
Esteve Sala, Vicente [3 ]
Sabater-Navarro, Jose [2 ]
机构
[1] Univ Cauca, Dept Elect Instrumentat & Control, Popayan, Colombia
[2] Miguel Hernandez Univ Elche, nBio Res Grp, Elche, Spain
[3] Univ Alicante, Dept Lenguaje & Sistemas Informat, Alicante, Spain
关键词
Electrodermal activity (EDA); Galvanic skin response (GSR); diabetic neuropathy; Bluetooth Low Energy (BLE); RESPONSES;
D O I
10.1109/CBMS.2019.00061
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Purpose: Poor electrodermal activity (EDA) may be related to diabetic neuropathy. The aims of this study were to investigate the characteristics of EDA, to design a portable electronic device capable of acquiring it and to formulate a hypothesis regarding the relationship between EDA and diabetic foot. Materials and methods: This study investigated the relationship between EDA signal and diabetic neuropathy using a self-designed device, and tested it with a procedure defined for diabetic foot screening. After that, mean skin conductance level (M-SCL), mean skin conductance response (M-SCR) to stimuli, and difference in mean SCL between feet (DBF) were obtained. Participants were assessed based on whether they had diabetes or not and on their clinical history and care habits. Afterwards, 3 groups were selected, namely reference, people with diabetes out of risk, and people with diabetes at risk of diabetic foot. Results: 22 patients were included in the final test. Several types of stimuli were applied through a test, and responses were recorded and analyzed. Diabetic patients reflected lower MSCL and M-SCR values. Statistical difference was found for those being at risk regarding M-SCR (P<0.01). Conclusion: A test protocol was defined, based on prior tests and measures, to acquire proper and reliable data. Lower SCL and SCR were found according to the diabetes progress. In particular, significant difference was found for M-SCR. No significant difference in DBF values for those at risk was found. These results have the potential to be used as part of a diagnostic tool, which may include other parameters and questionnaires, for diabetic foot screening.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 50 条
  • [21] Low-Cost NIR Measurement Device
    Mustafa, Luka
    Cerncic, Eva
    2015 4TH INTERNATIONAL WORKSHOP ON OPTICAL WIRELESS COMMUNICATIONS (IWOW), 2015, : 127 - 131
  • [22] A low-cost visual occlusion device
    Sancheol Lee
    Sekee Kil
    Taewhan Kim
    Behavior Research Methods, 2014, 46 : 935 - 948
  • [23] Low-cost screening for cervical cancer?
    不详
    REPRODUCTIVE HEALTH MATTERS, 2003, 11 (22) : 211 - 211
  • [24] PERCUSSION, A LOW-COST SCREENING TOOL
    LIM, DW
    HOSPITAL PRACTICE, 1988, 23 (5A): : 17 - 17
  • [25] Microfluidic device for low-cost screening of newborns for Severe Combined Immune Deficiency.
    Butte, MJ
    Wong, AP
    Sharpe, AH
    Whitesides, GM
    CLINICAL IMMUNOLOGY, 2005, 116 (03) : 282 - 282
  • [26] A LOW-COST IN-LINE DEVICE FOR EARLY SCREENING OF PERITONITIS IN PERITONEAL DIALYSIS PATIENTS
    Kaneda, Janelle
    Birk, Alisha
    Buckup, Mark
    Glockner, Eleanor
    Venook, Ross
    Sutha, Ken
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 77 (04) : 610 - 610
  • [27] The Use of the RETeval Portable Electroretinography Device for Low-Cost Screening: A Mini-Review
    Saad, Amr
    Turgut, Ferhat
    Sommer, Chiara
    Becker, Matthias
    DeBuc, Delia
    Barboni, Mirella
    Somfai, Gabor Mark
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (04) : 533 - 537
  • [28] Low-Cost Device for Transcutaneous Visualization of Veins
    Goldan, Daniela
    Ursache, Teofil Ilie
    Rotariu, Cristian
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 1, EHB-2023, 2024, 109 : 343 - 349
  • [29] Low-cost device for constructing sorption isotherms
    Gibert, O.
    Meot, J. M.
    Marouze, C.
    Brouat, J.
    DRYING TECHNOLOGY, 2006, 24 (12) : 1697 - 1704
  • [30] Erratum to: A low-cost visual occlusion device
    Sangcheol Lee
    Sekee Kil
    Taewhan Kim
    Behavior Research Methods, 2014, 46 (4) : 949 - 949