摘要
The main aim of present study is to investigate performance and fouling/cleaning behavior of reverse osmosis membranes and study heat treatment effect(s) as a membrane surface modification method on the membranes separation performance. For this purpose, performance of the reverse osmosis membranes as permeation flux, and Na and Mg rejections was investigated using response surface methodology (RSM) as functions of four main variables including trans-membrane pressure (TMP, bar), operating temperature (T, degrees C), cross flow (CF, L.h(-1)) and total dissolved solids (TDS, mg.L-1). Also, another RSM design was used to study the membrane fouling/cleaning behavior, i.e. the response of permeation flux recovery, vs. the variables of cross flow (CF, L.h(-1)), pH and cleaning time (t, min). Effects of the membrane surface modification via the heat treatment on its fouling resistance and cleaning performance were also investigated. The membranes were modified via washing with deionized water followed by immersing in deionized water at 70 degrees C for 3 h and then maintaining in deionized water at 4 degrees C and dark ambient until evaluation. The membranes' fouling resistance during 20 h operation and their fouling/cleaning behavior using synthetic foulant down to 80% of their initial permeation fluxes were determined at the experimentally obtained optimum conditions of fouling/cleaning cycles for both the modified and non-modified membranes. The optimum performance of the membrane with permeation flux of 59.1 kg.m(-2).h(-1) and Na and Mg rejections of 99.3 and 95.0% was identified at TMP, T, CF and TDS of 17 bar, 35 degrees C, 1200 L.h(-1) and 10000 mg.L-1, respectively. Also, the optimum permeation flux recovery was determined as 94% at CF of 250 L.h(-1), pH of 10 and cleaning time of 45 min. Permeation flux decline of the non-modified membrane was about 20%, while that of the modified membrane was found very lower as 3%. Also, the solutes rejection values were slightly increased from 99.3 to 99.4% and from 95.0 to 95.2% for Na and Mg, respectively for the modified membrane. In addition, it took about 3 h for the non-modified membrane and approximately 12 h for the modified membrane to be fouled as BSA added as foulant by 200 mg.L-1 BSA to the sodium chloride and magnesium sulfate aqueous solution of 10000 mg.L-1. Cleaning of the fouled membranes was performed and permeation flux recovery for the non-modified membrane was measured as 94.0% and for the modified membranes as 94.1%.
引用
收藏
页码:121 / 133
页数:13
相关论文
共 50 条
  • [21] Influence of pre-treatment combinations on RO membrane fouling
    Zhang, Jianhua
    Northcott, Kathy
    Duke, Mikel
    Scales, Peter
    Gray, Stephen R.
    DESALINATION, 2016, 393 : 120 - 126
  • [22] Effects of colloidal fouling and concentration polarization on RO membrane performance
    Han Yongping
    Lin Qiang
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 4604 - 4607
  • [23] Membrane fouling and wetting in a DCMD process for RO brine concentration
    Ge, Ju
    Peng, Yuelian
    Li, Zhehao
    Chen, Ping
    Wang, Shaobin
    DESALINATION, 2014, 344 : 97 - 107
  • [24] The Modified Fouling Index Ultrafiltration constant flux for assessing particulate/colloidal fouling of RO systems
    Salinas-Rodriguez, Sergio G.
    Amy, Gary L.
    Schippers, Jan C.
    Kennedy, Maria D.
    DESALINATION, 2015, 365 : 79 - 91
  • [25] Impact of membrane bioreactor operating conditions on fouling behavior of reverse osmosis membranes in MBR-RO processes
    Wu, Bing
    Kitade, Tamotsu
    Chong, Tzyy Haur
    Uemura, Tadahiro
    Fane, Anthony G.
    DESALINATION, 2013, 311 : 37 - 45
  • [26] Removal of PhACs and their impacts on membrane fouling in NF/RO membrane filtration of various matrices
    Li, Chen
    Yang, Yu
    Liu, Ye
    Hou, Li-an
    JOURNAL OF MEMBRANE SCIENCE, 2018, 548 : 439 - 448
  • [27] Influence of surface properties of RO membrane on membrane fouling for treating textile secondary effluent
    Yin, Zhonglong
    Yang, Cheng
    Long, Chao
    Li, Aimin
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (19) : 16253 - 16262
  • [28] Influence of surface properties of RO membrane on membrane fouling for treating textile secondary effluent
    Zhonglong Yin
    Cheng Yang
    Chao Long
    Aimin Li
    Environmental Science and Pollution Research, 2017, 24 : 16253 - 16262
  • [29] Effect of membrane properties on fouling in RO/NF membrane filtration of surficial groundwater.
    Hobbs, C
    Hong, SK
    Taylor, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U322 - U322
  • [30] Investigation of organic fouling of microfiltration membrane
    肖峰
    崔崇威
    马军
    Journal of Harbin Institute of Technology, 2005, (02) : 149 - 152