Comparison of chromatographic methods for hydrogen isotope separation by Pd beds

被引:36
|
作者
Fukada, S [1 ]
Fujiwara, H [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Quantum Phys & Nucl Engn, Higashi Ku, Fukuoka 8128581, Japan
关键词
isotope analysis; height equivalent to a theoretical plate; displacement chromatography; frontal chromatography; hydrogen; deuterium;
D O I
10.1016/S0021-9673(00)00821-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comparison among three chromatographic separation methods, i.e. hydrogen-displacement chromatography, self-displacement chromatography and frontal chromatography, is made in an experimental way using several gas mixtures of hydrogen and deuterium. There is small difference in the height equivalent to a theoretical plate (HETP) based on the plate theory among the three chromatographic techniques. The HETP value for the self-displacement chromatography is 3.9 cm, and that for the frontal or H-2-displacement chromatography is 3.0 cm at the same flow-rate. The self-displacement chromatography is more useful for the separation of a small amount of deuterium or tritium from other hydrogen isotopes under a moderate recovery ratio. Since the frontal chromatography uses no other gas than the sample, it is more convenient for the separation of deuterium from natural hydrogen even though a lower recovery ratio. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条