Resolution improvement in x-ray imaging with an energy-resolving detector

被引:0
|
作者
Persson, Mats [1 ]
Danielsson, Mats [1 ]
机构
[1] Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
关键词
Spatial resolution; super-resolution; photon-counting; Spectral imaging; Nonlinear partial volume effect; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2254572
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In x-ray imaging, irnproving spatial resolution an important goal, but developing dctectors with smaller is technically challenging. We demonstrate a technique for improving the spatialesolution by utilizing the fact that linear attenuation coefficients of all substances within the human body can be expressed, to a good approximation, as a linear combination of two basis functions, or three if there is iodine contrast present in the image. When the x rays pass an interface parallel to the beam direction, the exponential attenuation law makes the linear attenuation coefficient measured by the detector a nonlinear combination of the linear attenuation coefficients on each side of the interface. This so-called nonlinear partial volume effectcauses the spectral response to be dependent on the steepness of interfaces in the imaged volume. In this work, we show how this effect can be used to improve the spatial resolution' spectral)jec ion x-ray imaging and quantify the achievable resolution improvement. We simulate x-ray transmission imaging of sharp and gradual changes in the projected path length of iodine contrast with an ideal ettergy-resolving photon -counting detector and demonstrate that the slope of the transition can be determined from the registered spectrum. We simulate piecewise-linear transitions and show that the algorithm is able to reproduce the transition profile on a subpixel scale. The FWHM resolution of the method is 5-30 % of the pixel width. The results show that an energy -resolving detector can be used to improve spatial resolution when imaging interfaces of highly attenuating objects.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Investigation of Bias-Voltage Dependent Operational Characteristics of An Energy-Resolving Pixelated Cadmium Telluride Detector System Within An Experimental Benchtop X-Ray Fluorescence Imaging System
    Moktan, H.
    Panta, R. K.
    Cho, S. H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] Scientific impact of a noiseless energy-resolving detector for a future exoplanet-imaging mission
    Howe, Alex R.
    Stark, Christopher C.
    Sadleir, John E.
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2024, 10 (02)
  • [23] High resolution X-ray diffraction using energy resolving detectors
    Meyer, DC
    Seidel, A
    Richter, K
    Paufler, P
    EPDIC 7: EUROPEAN POWDER DIFFRACTION, PTS 1 AND 2, 2001, 378-3 : 200 - 205
  • [24] Improving radiation dose efficiency of X-ray differential phase contrast imaging using an energy-resolving grating interferometer and a novel rank constraint
    Ge, Yongshuai
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    OPTICS EXPRESS, 2016, 24 (12): : 12955 - 12968
  • [25] Performance improvement of the filter-type "transXend' energy-resolving detector by considering noise sensitivity
    Tsai, Tien-Hsiu
    Hamaguchi, Takumi
    Kanno, Ikuo
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2018, 55 (06) : 663 - 671
  • [26] Energy resolution of a silicon detector with the RX64 ASIC designed for X-ray imaging
    Bollini, D
    Rodriguez, AEC
    Dabrowski, W
    Garcia, AD
    Gambaccini, M
    Giubellino, P
    Grybos, P
    Idzik, M
    Marzari-Chiesa, A
    Montano, LM
    Prino, F
    Ramello, L
    Sitta, M
    Swientek, K
    Wheadon, R
    Wiacek, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03): : 458 - 466
  • [27] Effective atomic number image determination with an energy-resolving photon-counting detector using polychromatic X-ray attenuation by correcting for the beam hardening effect and detector response
    Kimoto, Natsumi
    Hayashi, Hiroaki
    Asakawa, Takumi
    Lee, Cheonghae
    Asahara, Takashi
    Maeda, Tatsuya
    Goto, Sota
    Kanazawa, Yuki
    Katsumata, Akitoshi
    Yamamoto, Shuichiro
    Okada, Masahiro
    APPLIED RADIATION AND ISOTOPES, 2021, 170 (170)
  • [28] Improvement of an X-ray imaging detector based on a scintillating guides screen
    Badel, X
    Galeckas, A
    Linnros, J
    Kleimann, P
    Fröjdh, C
    Petersson, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 129 - 135
  • [29] Characterization of a hybrid energy-resolving photon-counting detector
    Zang, A.
    Pelzer, G.
    Anton, G.
    Sune, R. Ballabriga
    Bisello, F.
    Campbell, M.
    Fauler, A.
    Fiederle, M.
    Cudie, X. Llopart
    Ritter, I.
    Tennert, F.
    Woelfel, S.
    Wong, W. S.
    Michel, T.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [30] High resolution X-ray imaging using a silicon strip detector
    Beuville, E
    Cahn, R
    Cederström, B
    Danielsson, M
    Hall, A
    Hasegawa, B
    Luo, L
    Lundqvist, M
    Nygren, D
    Oltman, E
    Walton, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3059 - 3063