Making Clear the Imperceptible: In-Line X-ray Phase Contrast Imaging

被引:0
|
作者
Gundogdu, O. [1 ,2 ]
Ismail, E. Che [1 ]
Jenneson, R. M. [1 ]
Bradley, D. A. [1 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[2] Royal Surrey Cty Hosp, NCCPM, Guildford GU2 7XX, Surrey, England
关键词
D O I
10.1166/asl.2009.321
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A wide range of materials of interest in the sciences and medicine can exhibit weak X-ray attenuation but yet still produce significant phase shifts at the same X-ray wavelengths. The use of phase information for imaging purposes therefore represents an attractive prospect. Images formed from differences in phase produced by an object manifest from the varying refraction of the X-rays. This paper presents a number of examples of X-ray phase-contrast images drawn from challenging biomedical situations, yielding strong improvements in contrast and resolution over conventional X-ray imaging methods. The X-ray phase-contrast images obtained herein have been obtained using a simple experimental setup comprising a bench-top micro-focal X-ray source rather than the more experimentally complex diffraction or interferometer based systems that are promoted in conjunction with the use of synchrotron radiation.
引用
收藏
页码:78 / 80
页数:3
相关论文
共 50 条
  • [41] An iterative phase retrieval algorithm for in-line x-ray phase imaging
    Meng, Fanbo
    Liu, Hong
    Wu, Xizeng
    OPTICS EXPRESS, 2007, 15 (13): : 8383 - 8390
  • [42] Investigation of gastric cancers in nude mice using X-ray in-line phase contrast imaging
    Tao, Qiang
    Luo, Shuqian
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [43] Progress in in-line phase-sensitive x-ray imaging
    Wu, X.
    Liu, H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2517 - 2517
  • [44] Quantitative evaluation methods of in-line x-ray phase contrast techniques
    Li Chen
    Li Zheng
    Li Cheng-Quan
    Yu Ai-Min
    CHINESE PHYSICS LETTERS, 2007, 24 (10) : 2823 - 2826
  • [45] Phase retrieval for in-line hard x-ray phase-contrast imaging with the Yang-Gu algorithm
    Yu, B
    Peng, X
    Tian, JD
    Niu, HB
    ICO20: BIOMEDICAL OPTICS, 2006, 6026
  • [46] Initial experimentation with in-line holography x-ray phase-contrast imaging with an ultrafast laser-based x-ray source
    Krol, Andrzej
    Kincaid, Russell
    Servol, Marina
    Kieffer, Jean-Claude
    Nesterets, Yakov
    Gureyev, Tim
    Stevenson, Andrew
    Wilkins, Steve
    Ye, Hongwei
    Lipson, Edward
    Toth, Remy
    Pogany, Andrew
    Coman, Ioana
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [47] In-line phase-contrast stereoscopic X-ray imaging for radiological purposes: An initial experimental study
    Siegbahn, E. A.
    Coan, P.
    Zhou, S. -A.
    Bravin, A.
    Brahme, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 345 - 349
  • [48] Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source
    Li Chen
    Li Zheng
    Yu Ai-Min
    Li Cheng-Quan
    CHINESE PHYSICS, 2007, 16 (08): : 2319 - 2324
  • [49] Using X-Ray In-Line Phase-Contrast Imaging for the Investigation of Nude Mouse Hepatic Tumors
    Tao, Qiang
    Li, Dongyue
    Zhang, Lu
    Luo, Shuqian
    PLOS ONE, 2012, 7 (06):
  • [50] System design considerations for a x-ray phase-contrast imaging system based on in-line holography
    Wu, XZ
    Liu, H
    Yan, AM
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 130 - 140