3D-conformal Accelerated Partial Breast Irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity

被引:33
|
作者
Dzhugashvili, Maia [1 ]
Tournay, Elodie [3 ]
Pichenot, Charlotte [2 ]
Dunant, Ariane [3 ]
Pessoa, Eduardo [1 ]
Khallel, Adel [1 ]
Gouy, Sebastien [4 ]
Uzan, Catherine [4 ]
Garbay, Jean-Remy [4 ]
Rimareix, Francoise [4 ]
Spielmann, Marc [5 ]
Vielh, Philippe [6 ]
Marsiglia, Hugo [1 ,7 ]
Bourgier, Celine [1 ]
机构
[1] Inst Gustave Roussy, Dept Radiat Oncol, Villejuif, France
[2] Inst Gustave Roussy, Dept Phys, Villejuif, France
[3] Inst Gustave Roussy, Biostat & Epidemiol Unit, Villejuif, France
[4] Inst Gustave Roussy, Dept Breast Surg, Villejuif, France
[5] Inst Gustave Roussy, Dept Breast Oncol, Villejuif, France
[6] Inst Gustave Roussy, Dept Pathol, Villejuif, France
[7] Univ Florence, I-50121 Florence, Italy
来源
RADIATION ONCOLOGY | 2009年 / 4卷
关键词
CONSERVING SURGERY; RADIATION-THERAPY; ELECTRON BOOST; TUMOR BED; RADIOTHERAPY; TARGET; CT; CANCER;
D O I
10.1186/1748-717X-4-70
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Accurate localisation of the lumpectomy cavity (LC) volume is one of the most critical points in 3D-conformal Partial breast irradiation (3D-APBI) treatment planning because the irradiated volume is restricted to a small breast volume. Here, we studied the role of the placement of surgical clips at the 4 cardinal points of the lumpectomy cavity in target delineation. Methods: Forty CT-based 3D-APBI plans were retrieved on which a total of 4 radiation oncologists, two trainee and two experienced physicians, outlined the lumpectomy cavity. The inter-observer variability of LC contouring was assessed when the CTV was defined as the delineation that encompassed both surgical clips and remodelled breast tissue. Results: The conformity index of tumour bed delineation was significantly improved by the placement of surgical clips within the LC (median at 0.65). Furthermore, a better conformity index of LC was observed according to the experience of the physicians (median CI = 0.55 for trainee physicians vs 0.65 for experienced physicians). Conclusions: The placement of surgical clips improved the accuracy of lumpectomy cavity delineation in 3D-APBI. However, a learning curve is needed to improve the conformity index of the lumpectomy cavity.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] 3D-conformal Partial Breast Irradiation (3D-CRT PBI): How to Optimize Its Reproducibility
    Valli, M.
    Martucci, F.
    Azinwi, N. C.
    Pesce, G. A.
    Canziani, L.
    Richetti, A.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S183 - S183
  • [22] Interim results of a phase I/II trial of 3D-conformal external beam accelerated partial breast irradiation in patients with early breast cancer
    Taghian, A. G.
    El-Din, M. Alm
    Smith, B. L.
    Ancukiewicz, M.
    MacDonald, S. S.
    Katz, A.
    Specht, M.
    Hirsch, A.
    Powell, S. N.
    Recht, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S4 - S4
  • [23] Long-term Cosmetic Outcomes and Toxicities of Proton Compared to Photon 3D-Conformal Accelerated Partial Breast Irradiation (3D-APBI)
    Galland, S.
    Pashtan, I. M.
    MacDonald, S. M.
    Ancukiewicz, M.
    Specht, M.
    Gadd, M. A.
    Smith, B. L.
    Recht, A.
    Taghian, A. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S195 - S196
  • [24] Image guidance in external beam accelerated partial breast irradiation: Comparison of surrogates for the lumpectomy cavity
    Hasan, Yasmin
    Kim, Leonard
    Martinez, Alvaro
    Vicini, Frank
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 619 - 625
  • [25] Image guidance in external beam accelerated partial breast irradiation: Comparison of surrogates for the lumpectomy cavity
    Hasan, Y
    Kim, L
    Weed, D
    Kestin, L
    Martinez, A
    Vicini, F
    Yan, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S138 - S138
  • [26] Setup Accuracy of Accelerated Partial Breast Irradiation Using Surgical Clips and Anatomical Surrogates
    Guo, B.
    Vassil, A. D.
    Xia, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E218 - E218
  • [27] Estimating the Value of Surgical Clips for Target Volume Delineation in External Beam Partial Breast Radiotherapy
    Ippolito, E.
    Trodella, L.
    Silipigni, S.
    D'Angelillo, R. M.
    Di Donato, A.
    Fiore, M.
    Grasso, A.
    Angelini, E.
    Ramella, S.
    Altomare, V.
    CLINICAL ONCOLOGY, 2014, 26 (11) : 677 - 683
  • [28] Radiographic evaluation of surgical clips is better than ultrasound for defining the lumpectomy cavity in breast boost treatment planning: A prospective clinical study
    Rabinovitch, R
    Finlayson, C
    Pan, ZX
    Lewin, J
    Humphries, S
    Biffl, W
    Franciose, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (02): : 313 - 317
  • [29] Triple-Negative Breast Cancer is Associated with Higher Risk of Local Recurrence after 3D-Conformal External Beam Accelerated Partial Breast Irradiation (3D-APBI)
    Pashtan, I. M.
    Ancukiewicz, M.
    Wo, J. Y.
    Hirsch, A. E.
    Smith, B. L.
    Powell, S. N.
    Recht, A.
    Taghian, A. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S53 - S53
  • [30] Effect of Lumpectomy cavity volume change on the CTV for accelerated partial breast irradiation: A deformable registration study
    Kim, L.
    DeCesare, S.
    Zhang, T.
    Vicini, F.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S511 - S512