3D-conformal Accelerated Partial Breast Irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity

被引:33
|
作者
Dzhugashvili, Maia [1 ]
Tournay, Elodie [3 ]
Pichenot, Charlotte [2 ]
Dunant, Ariane [3 ]
Pessoa, Eduardo [1 ]
Khallel, Adel [1 ]
Gouy, Sebastien [4 ]
Uzan, Catherine [4 ]
Garbay, Jean-Remy [4 ]
Rimareix, Francoise [4 ]
Spielmann, Marc [5 ]
Vielh, Philippe [6 ]
Marsiglia, Hugo [1 ,7 ]
Bourgier, Celine [1 ]
机构
[1] Inst Gustave Roussy, Dept Radiat Oncol, Villejuif, France
[2] Inst Gustave Roussy, Dept Phys, Villejuif, France
[3] Inst Gustave Roussy, Biostat & Epidemiol Unit, Villejuif, France
[4] Inst Gustave Roussy, Dept Breast Surg, Villejuif, France
[5] Inst Gustave Roussy, Dept Breast Oncol, Villejuif, France
[6] Inst Gustave Roussy, Dept Pathol, Villejuif, France
[7] Univ Florence, I-50121 Florence, Italy
来源
RADIATION ONCOLOGY | 2009年 / 4卷
关键词
CONSERVING SURGERY; RADIATION-THERAPY; ELECTRON BOOST; TUMOR BED; RADIOTHERAPY; TARGET; CT; CANCER;
D O I
10.1186/1748-717X-4-70
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Accurate localisation of the lumpectomy cavity (LC) volume is one of the most critical points in 3D-conformal Partial breast irradiation (3D-APBI) treatment planning because the irradiated volume is restricted to a small breast volume. Here, we studied the role of the placement of surgical clips at the 4 cardinal points of the lumpectomy cavity in target delineation. Methods: Forty CT-based 3D-APBI plans were retrieved on which a total of 4 radiation oncologists, two trainee and two experienced physicians, outlined the lumpectomy cavity. The inter-observer variability of LC contouring was assessed when the CTV was defined as the delineation that encompassed both surgical clips and remodelled breast tissue. Results: The conformity index of tumour bed delineation was significantly improved by the placement of surgical clips within the LC (median at 0.65). Furthermore, a better conformity index of LC was observed according to the experience of the physicians (median CI = 0.55 for trainee physicians vs 0.65 for experienced physicians). Conclusions: The placement of surgical clips improved the accuracy of lumpectomy cavity delineation in 3D-APBI. However, a learning curve is needed to improve the conformity index of the lumpectomy cavity.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] 3D-conformal Accelerated Partial Breast Irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity
    Maia Dzhugashvili
    Elodie Tournay
    Charlotte Pichenot
    Ariane Dunant
    Eduardo Pessoa
    Adel Khallel
    Sébastien Gouy
    Catherine Uzan
    Jean-Rémy Garbay
    Françoise Rimareix
    Marc Spielmann
    Philippe Vielh
    Hugo Marsiglia
    Céline Bourgier
    Radiation Oncology, 4
  • [2] SURGICAL CLIPS ASSIST IN THE VISUALIZATION OF THE LUMPECTOMY CAVITY IN THREE-DIMENSIONAL CONFORMAL ACCELERATED PARTIAL-BREAST IRRADIATION
    Dzhugashvili, Maia
    Pichenot, Charlotte
    Dunant, Ariane
    Balleyguier, Corinne
    Delaloge, Suzette
    Mathieu, Marie-Christine
    Garbay, Jean-Remy
    Marsiglia, Hugo
    Bourgier, Celine
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1320 - 1324
  • [3] The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation
    Weed, DW
    Yan, D
    Martinez, AA
    Vicini, FA
    Wilkinson, TJ
    Wong, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 484 - 492
  • [4] Preliminary Toxicity Analysis of 3D-Conformal and Intraoperative Accelerated Partial Breast Irradiation
    Sreeraman, R.
    Mellon, E. A.
    Mierzejewski, A.
    Correa, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S213 - S214
  • [5] Impact of increasing margin around the lumpectomy cavity to define the planning target volume for 3d conformal external beam accelerated partial breast irradiation
    Cox, Brett W.
    Horst, Kathleen C.
    Thornton, Sherri
    Dirbas, Frederick M.
    MEDICAL DOSIMETRY, 2007, 32 (04) : 254 - 262
  • [6] Acclerated partial breast irradiation: Comparison between two 3D-conformal treatment plans by the conformal index
    Bassols, M. Lacruz
    de Dios, N. Rodriguez
    Jordana, J. Quera
    Cepria, E. Fernandez-Velilla
    Atiesas, X. Sanz
    Galan, J. Lozano
    Puig, C. Llonch
    Montes, P. Vinals
    Guerra, J. Lopez
    Arnalot, P. Foro
    Castillejo, A. Reig
    Lopez, M. Algara
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S258 - S258
  • [7] Comparison of PET/CT and CT for delineation of lumpectomy cavity for partial breast irradiation
    Ford, E. C.
    Lavely, W.
    Frassica, D.
    Myers, L.
    Asrari, F.
    Wahl, R.
    Zellars, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S225 - S226
  • [8] Comparison of intensity modulated and 3D-conformal treatment breast plans with and without lumpectomy boost
    Thatcher, SH
    Jursinic, P
    Yun, H
    White, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S394 - S394
  • [9] The added value of surgical clips in target volume determination in accelerated partial breast cancer irradiation
    Dzhugashvili, M.
    Dunant, A.
    Pichenot, C.
    Verstraet, R.
    Uzan, C.
    Gouy, S.
    Garbay, J.
    Rimareix, F.
    Marsiglia, H.
    Bourgier, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S173 - S173
  • [10] Preliminary Results using 3D-conformal External Beam (3D-CRT) Accelerated Partial Breast Irradiation (APBI) with Reduced Treatment Margins
    Horst, K. C.
    Goffinet, D. R.
    Dirbas, F. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S220 - S220