A Nanosensor Interface Based on Delta-Sigma Arrays

被引:0
|
作者
Crescentini, M. [1 ]
Rossi, M. [1 ]
Bennati, M. [1 ]
Thei, F. [1 ]
Baschirotto, A. [2 ]
Tartagni, M. [1 ]
机构
[1] Univ Bologna, Sch Engn 2, Campus Cesena,Via Venezia 52, I-47023 Cesena, Italy
[2] Univ Milano Bicocca, Milan, Italy
关键词
SOLID-STATE NANOPORES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An emerging area of biosensors is based on the use of structures provided by recent advances of Nanotechnology such as nanowires, nanotubes and nanopores. Among them, the integration of natural nanopores such as ion channels with electronics is a promising approach to develop rapid, sensitive and reliable biosensors able to detect low concentration of target molecules or DNA sequencing. This paper presents a compact and low-cost system able to readout, process and record current in the pA range, provided by biological or synthetic nanopores. The approach is based on the idea that by processing the outputs of a large amount of single-molecule nanosensors would result in a significant increase of resolution and signal-to-noise ratio. The approach consists of an electronic interface able to detect current-based array of nanosensors, where the management of very large amount of data is critical for the readout process. As working example, we acquired the single molecule signals derived from non-covalent bindings between single alpha-hemolysin pores, embedded into an artificial lipid bilayer, and beta-cyclodextrin molecules. The system embeds the electronic readout with the microfluidic where is placed the nanosensor array. The electronic interface is a 0.5mm(2) current amplifier based on an array of Sigma Delta converters. Then the high rate data streams are processed and downsampled by a DSP that communicates with a PC via a USB interface for data processing and storage.
引用
收藏
页码:155 / +
页数:2
相关论文
共 50 条
  • [21] Compact ultrasonic beamformer based on delta-sigma modulation
    Lie, Ioan
    Tanase, Mihail Eugen
    Lascu, Dan
    Lascu, Mihaela
    WSEAS Transactions on Circuits and Systems, 2006, 5 (08): : 1315 - 1322
  • [22] TABLE-BASED SIMULATION OF DELTA-SIGMA MODULATORS
    BISHOP, RJ
    PAULOS, JJ
    STEER, MB
    ARDALAN, SH
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1990, 37 (03): : 447 - 451
  • [23] Generalized delta-sigma modulator based on viterbi algorithm
    Zrilic, D
    Petrovic, G
    MELECON '98 - 9TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 1998, : 637 - 640
  • [24] DESIGN AND ANALYSIS OF DELTA-SIGMA BASED IIR FILTERS
    JOHNS, DA
    LEWIS, DM
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 1993, 40 (04): : 233 - 240
  • [25] Spatio-temporal delta-sigma modulation for shared wideband transmit arrays
    Scholnik, DP
    Coleman, JO
    Bowling, D
    Neel, M
    PROCEEDINGS OF THE IEEE 2004 RADAR CONFERENCE, 2004, : 85 - 90
  • [26] Delta-Sigma Modulator Based Spectrum Sensing Transceiver
    Badran, Tamer
    Aboushady, Hassan
    23RD IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS CIRCUITS AND SYSTEMS (ICECS 2016), 2016, : 443 - 443
  • [27] Delta-Sigma Digital Current Sensor Based On GMR
    Wang, Zhili
    Qian, Zhenghong
    Huang, Xiaowei
    1ST INTERNATIONAL SYMPOSIUM ON SPINTRONIC DEVICES AND COMMERCIALIZATION (ISSDC2010), 2011, 263
  • [28] A Delta-Sigma Interface Circuit for Capacitive Sensors With an Automatically Calibrated Zero Point
    Shin, Dong-Yong
    Lee, Hyunjoong
    Kim, Suhwan
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2011, 58 (02) : 90 - 94
  • [29] ISFET's Interface Circuit for Biomedical Applications Using Delta-Sigma Modulation
    Bumrungyat, Puvanat
    Kasemsuwan, Varakorn
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [30] A capacitive pressure sensor interface using oversampling Delta-Sigma demodulation techniques
    Yamada, M
    Watanabe, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (01) : 3 - 7