Comparative LC-MS/MS and HPLC-UV Analyses of Meropenem and Piperacillin in Critically III Patients

被引:6
|
作者
Paal, Michael [1 ]
Heilmann, Marcus [2 ]
Koch, Simone [2 ]
Bertsch, Thomas [2 ]
Steinmann, Joerg [3 ]
Hoehl, Rainer [3 ]
Liebchen, Uwe [4 ]
Schuster, Carina [1 ]
Kleine, Frederick M. [1 ]
Vogeser, Michael [1 ]
机构
[1] Univ Hosp, Inst Lab Med, LMU Munich, Munich, Germany
[2] Paracelsus Med Univ, Gen Hosp Nuremberg, Inst Clin Chem Lab Med & Transfus Med, Nurnberg, Germany
[3] Paracelsus Med Univ, Gen Hosp Nuremberg, Inst Med Microbiol Hyg & Clin Infectiol, Nurnberg, Germany
[4] Univ Hosp, Dept Anesthesiol, LMU Munich, Munich, Germany
关键词
therapeutic drug monitoring (TDM); antibiotics; intensive care units (ICU); pharmacokinetic and pharmacodynamic (PK/PK); isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS); high performance liquid chromatography with ultra-violet detector (HPLC-UV); BETA-LACTAM ANTIBIOTICS; HUMAN SERUM; ILL PATIENTS; CARE; QUANTIFICATION; INFECTION; CEFEPIME; MODELS;
D O I
10.7754/Clin.Lab.2019.190210
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Therapeutic drug monitoring (TDM) of beta-lactam antibiotics has become a valuable tool to guide dosing in critically ill patients. The main goal of the study was to compare two routinely used techniques for beta-lactam TDM in intensive care unit (ICU) patient samples, namely isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) and high-performance liquid chromatography combined with ultra-violet detection (HPLC-UV). Methods: A set of 80 sera/plasma samples from ICU patients receiving therapeutic meropenem or piperacillin dosage was investigated. Sample duplicates and quality assessment samples were assayed in parallel with an in-house LC-MS/MS and a commercially available IVD HPLC-UV kit. A pharmacokinetic and pharmacodynamic (PK/PD) target with >= 22.5 mg/L for piperacillin and >= 8.0 mg/L for meropenem was used for medical assessment of trough sample (n = 40) antibiotic concentrations. Results: There was no difference between serum and Li-heparin plasmas. Concentration deviations were found for 4% of meropenem and 17% of piperacillin samples. Eliminating the influence of the systemic bias of approximately 10% for piperacillin, measurement discrepancies >= 25% between LC-MS/MS and HPLC-UV analyses were only observed for approximate to 4 - 6% of all samples. In the same way, identical PK/PD target attainment rates of 50 - 60% could be obtained. Conclusions: After correction of the analytical bias for piperacillin measurements, both methods showed comparable results, also with respect to clinical decision limits. HPLC-UV analysis is an adequate TDM methodology for testing of beta-lactam antibiotics in centers where no special knowledge in LC-MS/MS based TDM is present. However, potential matrix effects, interferences, and calibration issues for both methods must be taken into account.
引用
收藏
页码:1675 / 1680
页数:6
相关论文
共 50 条
  • [11] Development and validation of HPLC-UV and LC-MS/MS methods for the quantitative determination of a novel aminothiazole in preclinical samples
    Basavanakatti, Vinay N.
    Ali, Mohammad
    Bharathi, D. R.
    Murtuja, Sheikh
    Sinha, Barij Nayan
    Jayaprakash, Venkatesan
    Shakeel, Faiyaz
    BMC CHEMISTRY, 2024, 18 (01)
  • [12] Comparison of blood sirolimus, tacrolimus and everolimus concentrations measured by LC-MS/MS, HPLC-UV and immunoassay methods
    Sallustio, Benedetta C.
    Noll, Benjamin D.
    Morris, Raymond G.
    CLINICAL BIOCHEMISTRY, 2011, 44 (2-3) : 231 - 236
  • [13] Pharmacokinetic and Metabolic Studies of ADTM: A Novel Danshensu Derivative Confers Cardioprotection by HPLC-UV and LC-MS/MS
    Li, Sai
    Shan, Luchen
    Zhang, Zaijun
    Li, Wei
    Liao, Kaiyi
    Li, Sha
    Sheng, Xiaoyan
    Yu, Pei
    Wang, Yuqiang
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (06) : 872 - 878
  • [14] LC-MS/MS method for simultaneous determination of linezolid, meropenem, piperacillin and teicoplanin in human plasma samples
    Ferrari, Davide
    Ripa, Marco
    Premaschi, Simone
    Banfi, Giuseppe
    Castagna, Antonella
    Locatelli, Massimo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 169 : 11 - 18
  • [15] Determination of meropenem in bacterial media by LC-MS/MS
    Huang, Liusheng
    Haagensen, Janus
    Verotta, Davide
    Lizak, Patricia
    Aweeka, Francesca
    Yang, Katherine
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 71 - 76
  • [16] Determination of Meropenem in Rabbit Plasma by LC-MS/MS
    Lin, Guanyang
    Zhang, Haiyan
    Xue, Feng
    Li, Wenjuan
    Liu, Naihua
    Chen, Lianguo
    Wang, Xianqin
    Xu, Renai
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (10): : 1895 - 1900
  • [17] Detection of nimesulide metabolites in rat plasma and hepatic subcellular fractions by HPLC-UV/DAD and LC-MS/MS studies
    Küçükgüzel, SG
    Küçükgüzel, I
    Oral, B
    Sezen, S
    Rollas, S
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2005, 30 (1-2) : 127 - 134
  • [18] Detection of nimesulide metabolites in rat plasma and hepatic subcellular fractions by HPLC-UV/DAD and LC-MS/MS studies
    Ş. Güniz Küçükgüzel
    İlkay Küçükgüzel
    Başak Oral
    Sena Sezen
    Sevİm Rollas
    European Journal of Drug Metabolism and Pharmacokinetics, 2005, 30 : 127 - 134
  • [19] Analyses of benzodiazapines in a series of matrices by HPLC and LC-MS
    Phillips, Lauren M.
    Anderson, Kevin M.
    Hyslop, Richard M.
    Karnilaw, Peter
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [20] Determination of penicillins in milk using LC-UV, LC-MS and LC-MS/MS
    Martinez-Huelamo, Miriam
    Jimenez-Gamez, Esther
    Pilar Hermo, Maria
    Barron, Dolores
    Barbosa, Jose
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (14) : 2385 - 2393