Axial load behaviour of concrete-filled steel tubular columns

被引:23
|
作者
De Nardin, S. [1 ]
El Debs, A. L. H. C. [1 ]
机构
[1] Univ Sao Paulo, Dept Struct Engn, BR-13560 Sao Carlos, Brazil
关键词
buildings; structures & design; columns; composite structures;
D O I
10.1680/stbu.2007.160.1.13
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports an experimental study of concrete-filled steel tubular columns. Six short columns subjected to concentric load were tested. Columns of square, circular and rectangular cross-sections with two steel tube thicknesses were considered. The experimental results showed that the ductility of high-strength concrete increases when confined by a steel tube, but the load-carrying capacity remains the same. The confinement effect does not increase the capacity of the columns because the axial strain of the high-strength concrete core is low up to the point where the column reaches its ultimate load. A model to predict the load against strain behaviour was proposed and the pre-peak and post-peak behaviours of concrete-filled steel columns axially loaded could be predicted from the behaviours of steel tube and concrete core.
引用
收藏
页码:13 / 22
页数:10
相关论文
共 50 条
  • [31] Concrete-Filled Steel Tubular (CFTS) Columns Subjected to Eccentric Compressive Load
    Kedziora, Slawomir
    Anwaar, Muhammad Omer
    PROCEEDINGS OF THE 15TH STABILITY OF STRUCTURES SYMPOSIUM, 2019, 2060
  • [32] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [33] Axial behaviour of slender concrete-filled steel tube square columns strengthened with square concrete-filled steel tube jackets
    Zhu, Tao
    Liang, Hongjun
    Lu, Yiyan
    Li, Weijie
    Zhang, Hong
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1074 - 1086
  • [34] Fire behaviour of fire-protected concrete-filled steel tubular columns
    Lou, Guo-Biao
    Tan, Rui-Xin
    Qi, Hong-Hui
    Rao, Wen-Ting
    Huang, Dai-Fa
    Zhao, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [35] Behaviour of flush end plate joints to concrete-filled steel tubular columns
    Wang, Jing-Feng
    Han, Lin-Hai
    Uy, Brian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (04) : 925 - 939
  • [36] BEHAVIOUR AND ULTIMATE STRENGTH OF LONG CONCRETE-FILLED STEEL TUBULAR COLUMNS.
    Cai Shaohuai
    Gu Wanli
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1985, 6 (01): : 32 - 40
  • [37] Seismic behaviour of round-ended concrete-filled steel tubular columns
    Wang Z.
    Zheng Y.
    Lai Z.
    Shen W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (05): : 183 - 194
  • [38] Time-dependent behaviour of expansive concrete-filled steel tubular columns
    Wang, Yuyin
    Geng, Yue
    Ranzi, Gianluca
    Zhang, Sumei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) : 471 - 483
  • [39] Behaviour of hybrid fibre reinforced concrete-filled steel tubular beams and columns
    Karuppanan, Kathiresan
    Govindasamy, Vennila
    MATERIA-RIO DE JANEIRO, 2020, 25 (01):
  • [40] Behaviour of FRP-strengthened concrete-filled steel tubular composite columns
    College of Civil Engineering, Fuzhou University, Fujian, Fuzhou 350108, China
    不详
    Harbin Gongye Daxue Xuebao, 1600, SUPPL. 2 (18-21):