Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction

被引:41
|
作者
Inoue, Tadahisa [1 ,2 ]
Naitoh, Itaru [3 ]
Okumura, Fumihiro [1 ]
Ozeki, Takanori [1 ]
Anbe, Kaiki [1 ]
Iwasaki, Hiroyasu [1 ]
Nishie, Hirotada [1 ]
Mizushima, Takashi [1 ]
Sano, Hitoshi [1 ]
Nakazawa, Takahiro [3 ]
Yoneda, Masashi [2 ]
Joh, Takashi [3 ]
机构
[1] Gifu Prefectural Tajimi Hosp, Dept Gastroenterol, Tajimi, Japan
[2] Aichi Med Univ, Sch Med, Dept Gastroenterol, Nagakute, Aichi, Japan
[3] Nagoya City Univ, Grad Sch Med Sci, Dept Gastroenterol & Metab, Nagoya, Aichi, Japan
关键词
malignant hilar biliary obstruction; recurrent biliary obstruction; reintervention; revisionary stent; self-expandable metallic stent; SIDE-BY-SIDE; DEPLOYMENT; DRAINAGE; CELL;
D O I
10.1111/den.12657
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Methods: Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Results: Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Conclusion: Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [41] Large cell width expandable metal stents for endoscopic bilateral stent within stent placement of malignant hilar biliary obstruction
    Chahal, Prabhleen
    Baron, Todd
    Petersen, Bret
    Topazian, Mark
    Gostout, Christopher
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 : S78 - S79
  • [42] Clinical outcomes after multiple self-expandable metallic stent placement using stent-in-stent technique for malignant gastric outlet obstruction
    Mo, Jin Won
    Kim, Young Min
    Kim, Jie-Hyun
    Shin, Seung Yong
    Youn, Young Hoon
    Park, Hyojin
    MEDICINE, 2020, 99 (21) : E19432
  • [43] Cross-Wired Metallic Stents in Endoscopic Bilateral Stent-In-Stent Placement for Malignant Hilar Biliary Obstruction
    Taniguchi, Yohei
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB649 - AB649
  • [44] Endoscopic Reintervention Following Multiple Metallic Stent Placement for Hilar Malignant Biliary Stricture
    Kawakubo, Kazumichi
    Kuwatani, Masaki
    Sano, Itsuki
    Sugiura, Ryo
    Kato, Shin
    Sakamoto, Naoya
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB617 - AB617
  • [45] PERCUTANEOUS ENDOBILIARY RADIOFREQUENCY ABLATION AND SELF-EXPANDABLE METAL STENT PLACEMENT VERSUS STENT PLACEMENT ALONE FOR MALIGNANT BILIARY OBSTRUCTION
    Cui, Wei
    Li, Jiaping
    GUT, 2019, 68 : A129 - A130
  • [46] A novel controllable cannula with a short flexible tip for reintervention after stent-by-stent placement in malignant hilar biliary obstruction
    Inoue, Tadahisa
    Ibusuki, Mayu
    Yoneda, Masashi
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2023, 32 (01) : 120 - 121
  • [47] Novel J-tip guidewire for reintervention after stent-by-stent placement in patients with malignant hilar biliary obstruction
    Inoue, Tadahisa
    Ibusuki, Mayu
    Kitano, Rena
    Sakamoto, Kazumasa
    Kimoto, Satoshi
    Kobayashi, Yuji
    Sumida, Yoshio
    Nakade, Yukiomi
    Ito, Kiyoaki
    Yoneda, Masashi
    ENDOSCOPY INTERNATIONAL OPEN, 2022, 10 (09) : E1291 - E1296
  • [48] Management of acute cholangitis as a result of occlusion from a self-expandable metallic stent in patients with malignant distal and hilar biliary obstructions
    Shiomi, Hideyuki
    Matsumoto, Kazuya
    Isayama, Hiroyuki
    DIGESTIVE ENDOSCOPY, 2017, 29 : 88 - 93
  • [49] Self-expandable metallic stent placement for palliation in gastric outlet obstruction
    Maetani, Iruru
    ANNALS OF PALLIATIVE MEDICINE, 2014, 3 (02) : 54 - 64
  • [50] Predictive factors for pancreatitis and cholecystitis in endoscopic covered self-expandable metallic stent placement for distal malignant biliary obstruction
    Toyohara, Tadashi
    Watanabe, Takashi
    Uno, Konomu
    Suzuki, Takanori
    Kanda, Takeo
    Araki, Hiromichi
    Suzuki, Yuka
    Nagao, Kazuhiro
    Mizuno, Yusuke
    Kusakabe, Atsunori
    Kanie, Hiroshi
    Shimizu, Syuya
    Yamada, Tomonori
    Hayashi, Katsumi
    Nakazawa, Takahiro
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 246 - 246