A novel real-time PCR to detect Chlamydia trachomatis in first-void urine or genital swabs

被引:39
|
作者
Jaton, Katia [1 ]
Bille, Jacques [1 ]
Greub, Gilbert [1 ]
机构
[1] Univ Lausanne, Inst Microbiol, CH-1015 Lausanne, Switzerland
关键词
D O I
10.1099/jmm.0.46675-0
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Screening for Chlamydia trachomatis infections can be performed on urine samples and genital swabs using molecular techniques. A novel approach was developed that combined an automated extraction procedure, an automated liquid-handling system and real-time PCR to detect C. trachomatis from urine or swabs. This novel real-time PCR approach was compared to the commercial Cobas Amplicor system on 628 specimens. In a retrospective analysis, 51 samples that tested positive using the Cobas assay were also positive with the real-time PCR, whereas the 49 samples negative with Cobas were also negative with the real-time PCR, for an overall agreement of 100%. Among 528 prospective samples consecutively received at the authors' laboratory with a request for C. trachomatis PCR, five PCR reactions were inhibited when tested with Cobas. These five inhibited samples were found negative with the real-time PCR. Among the remaining 523 samples, 45 (8.6%) were positive with both methods, 476 (91%) were negative with both methods, and 2 (0.4%) were positive with Cobas but negative with the real-time PCR. Thus, when considering Cobas as the gold standard, the overall agreement was 99.6%, the sensitivity of the real-time PCR was 95.7% and the specificity was 100%. The two discrepant samples were retested in parallel and were found negative with both methods. When testing a batch of 25 samples, both reagent costs and laboratory technician time were reduced with the new technique (7.30 euros per sample and 134 min) compared to Cobas (11.20 euros per sample and 232 min). Moreover, due to reduced organizational constraints, the median time from sample reception to result was only 24 In using the automated platform. Overall, this novel real-time PCR approach exhibited an excellent specificity and a sensitivity similar to that of Cobas Amplicor PCR for the detection of C. trachomatis. Given its high throughput potential and low costs/laboratory technician time requirement, it may be useful for future use in large C. trachomatis screening programs.
引用
收藏
页码:1667 / 1674
页数:8
相关论文
共 50 条
  • [21] DIAGNOSIS OF CHLAMYDIA-TRACHOMATIS INFECTIONS IN MEN AND WOMEN BY TESTING FIRST-VOID URINE BY LIGASE CHAIN-REACTION
    CHERNESKY, MA
    JANG, D
    LEE, H
    BURCZAK, JD
    HU, H
    SELLORS, J
    TOMAZICALLEN, SJ
    MAHONY, JB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (11) : 2682 - 2685
  • [22] Comparison of a transcription-mediated amplification assay and polymerase chain reaction for detection of Chlamydia trachomatis in first-void urine
    Pasternack, R
    Vuorinen, P
    Miettinen, A
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (02) : 142 - 144
  • [23] Diagnosis of Chlamydia trachomatis infection in high-risk females with PCR on first void urine
    Olafsson, JH
    Davidsson, S
    Karlsson, SM
    Palsdottir, R
    Steingrimsson, O
    ACTA DERMATO-VENEREOLOGICA, 1996, 76 (03) : 226 - 227
  • [24] A NOVEL RAPID REAL-TIME PCR TEST FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS IN PATIENT SAMPLES
    Cornwell, Clare
    Scully, Philip
    Tyson, John
    Sails, Andy
    Ohalloran, Jonathan
    SEXUALLY TRANSMITTED INFECTIONS, 2019, 95 : A226 - A226
  • [25] Development of a disposable cartridge real-time PCR test for detection of Chlamydia trachomatis directly from urine
    Brennan, Desmond
    O'Connor, Louise
    Cormican, Martin
    Kileen, James
    Clancy, Eoin
    Smith, Terry J.
    Galvin, Paul
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 339
  • [26] EVALUATION OF THE TRIPLEX REAL-TIME PCR ASSAY FOR DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE IN URINE AND VAGINAL
    Samleerat, T.
    Pookkapund, S.
    Techanun, S.
    Jitvatcharanon, K.
    Leechanachai, P.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A92 - A92
  • [27] Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens
    Levett, P. N.
    Brandt, K.
    Olenius, K.
    Brown, C.
    Montgomery, K.
    Horsman, G. B.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (06) : 2109 - 2111
  • [28] Inhibition of PCR in genital and urine specimens submitted for Chlamydia trachomatis testing
    Toye, B
    Woods, W
    Bobrowska, M
    Ramotar, K
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (08) : 2356 - 2358
  • [29] Prevalence of genital Chlamydia trachomatis in women using PCR on urine specimen
    Mittal, Vineeta
    Agarwal, Jyotsna
    Jain, Amita
    Verma, Anoop K.
    BIOMEDICAL RESEARCH-INDIA, 2010, 21 (03): : 301 - 304
  • [30] Validation of a laboratory-developed real-time PCR protocol for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine
    Hopkins, M. J.
    Ashton, L. J.
    Alloba, F.
    Alawattegama, A.
    Hart, I. J.
    SEXUALLY TRANSMITTED INFECTIONS, 2010, 86 (03) : 207 - 211