The effect of the frictional heat on retention and efficiency in thermostated or insulated chromatographic columns packed with sub-2-μm particles

被引:7
|
作者
Lambert, Nandor [1 ]
Felinger, Attila [1 ,2 ,3 ,4 ]
机构
[1] MTA PTE Mol Interact Separat Sci Res Grp, Ifjusag Utja 6, H-7624 Pecs, Hungary
[2] Univ Pecs, Dept Analyt & Environm Chem, Ifjusag Utja 6, H-7624 Pecs, Hungary
[3] Univ Pecs, Szentagothai Res Ctr, Ifjusag Utja 6, H-7624 Pecs, Hungary
[4] Univ Pecs, Inst Bioanal, Med Sch, Szigeti Ut 12, H-7624 Pecs, Hungary
关键词
UHPLC; Column efficiency; Frictional heat; Sub-2-mu m particles; Thermostating; Insulation; PRESSURE LIQUID-CHROMATOGRAPHY; MASS-TRANSFER KINETICS; PARKING-MOMENT ANALYSIS; TEMPERATURE-GRADIENTS; CORE-SHELL; MU-M; PERFORMANCE; PHASE; DISSIPATION; STRATEGY;
D O I
10.1016/j.chroma.2018.06.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The mass-transfer properties of a core-shell packing material with 1.6 mu m particle diameter, and that of a fully porous packing material with 1.7 mu m particle diameter were investigated and compared. The first absolute and the second central moments of the peaks of the homologous series of alkylbenzenes, over a wide range of mobile phase velocities were measured and used for the calculation of the mass transfer coefficients. For the evaluation of the band broadening caused by the thermal dissimilarities, the measurements were carried out under thermostated conditions and also at near adiabatic insulation of the columns. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 28 条
  • [1] Effect of extra-column volume on practical chromatographic parameters of sub-2-μm particle-packed columns in ultra-high pressure liquid chromatography
    Wu, Naijun
    Bradley, Ashley C.
    Welch, Christopher J.
    Zhang, Li
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (16) : 2018 - 2025
  • [2] Pharmaceutical applications on columns packed with sub-2 μm particles
    Russo, Rossana
    Guillarme, Davy
    Nguyen, Dao T-T.
    Bicchi, Carlo
    Rudaz, Serge
    Veuthey, Jean-Luc
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (03) : 199 - 208
  • [3] Characterisation of RPLC columns packed with porous sub-2 μm particles
    Petersson, Patrik
    Euerby, Melvin R.
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (13) : 2012 - 2024
  • [4] Facts and myths about columns packed with sub-3 μm and sub-2 μm particles
    Fekete, Szabolcs
    Ganzler, Katalin
    Fekete, Jeno
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (01) : 56 - 64
  • [5] Systematic comparison of a new generation of columns packed with sub-2 μm superficially porous particles
    Bobaly, Balazs
    Guillarme, Davy
    Fekete, Szabolcs
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (03) : 189 - 197
  • [6] Comparison of columns packed with porous sub-2 μm particles and superficially porous sub-3 μm particles for peptide analysis at ambient and high temperature
    Ruta, Josephine
    Guillarme, Davy
    Rudaz, Serge
    Veuthey, Jean-Luc
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (16) : 2465 - 2477
  • [7] Modern analytical supercritical fluid chromatography using columns packed with sub-2 μm particles: A tutorial
    Novakova, Lucie
    Perrenoud, Alexandre Grand-Guillaume
    Francois, Isabelle
    West, Caroline
    Lesellier, Eric
    Guillarme, Davy
    ANALYTICA CHIMICA ACTA, 2014, 824 : 18 - 35
  • [8] Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure
    Cunliffe, Jennifer M.
    Maloney, Todd D.
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) : 3104 - 3109
  • [9] Ultra-Fast Separations of Pharmaceutical Compounds with 10 mm Columns Packed with Sub-2 μm Particles
    Guillarme, Davy
    Schelling, Cedric
    Rudaz, Serge
    Veuthey, Jean-Luc
    LC GC EUROPE, 2008, 21 (10) : 488 - +
  • [10] Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns
    Omamogho, Jesse O.
    Glennon, Jeremy D.
    ANALYTICAL CHEMISTRY, 2011, 83 (05) : 1547 - 1556