Design of Diagnostic Multileaf Collimator Based On the Monte Carlo Simulation for Dose Reduction of Diagnostic Radiography

被引:0
|
作者
Han, S.
Ji, Y.
Kim, K.
Choi, S.
Jung, H.
Park, S.
机构
关键词
D O I
10.1118/1.4955906
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3405 / 3405
页数:1
相关论文
共 50 条
  • [31] Monte Carlo estimation of absorbed dose to organs in diagnostic radiology
    Alonso, M
    Barriuso, T
    Castañeda, MJ
    Díaz-Caneja, N
    Gutiérrez, I
    Sarmiento, JJ
    Villar, E
    HEALTH PHYSICS, 1999, 76 (04): : 388 - 392
  • [32] Monte Carlo Basics for Radiation Dose Assessment in Diagnostic Radiology
    Boone, John M.
    McNitt-Gray, Michael F.
    Hernandez, Andrew M.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (06) : 793 - 794
  • [33] A theoretical multileaf collimator model for fast Monte Carlo dose calculation of linac 6/10 MV photon beams
    Aboulbanine, Zakaria
    El Khayati, N.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [34] Monte Carlo Modeling of Modulated Electron Beams Delivered Through a Photon Multileaf Collimator
    Tynan, P.
    Stathakis, S.
    Esquivel, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [35] Calculations of a millennium multileaf collimator using the DPM and BEAM/DOSXYZ Monte Carlo codes
    Tyagi, N
    Chetty, I
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1230 - 1230
  • [36] Novel multileaf collimator designs with tongues and grooves in leaf end and Monte Carlo simulations
    Cui, Weijie
    Tian, Yuan
    Dai, Jianrong
    MEDICAL DOSIMETRY, 2024, 49 (03) : 254 - 262
  • [37] Efficacy of the Monte Carlo method and dose reduction strategies in paediatric panoramic radiography
    Lee, Chena
    Park, Bora
    Lee, Sam-Sun
    Kim, Jo-Eun
    Han, Sang-Sun
    Huh, Kyung-Hoe
    Yi, Won-Jin
    Heo, Min-Suk
    Choi, Soon-Chul
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [38] Efficacy of the Monte Carlo method and dose reduction strategies in paediatric panoramic radiography
    Chena Lee
    Bora Park
    Sam-Sun Lee
    Jo-Eun Kim
    Sang-Sun Han
    Kyung-Hoe Huh
    Won-Jin Yi
    Min-Suk Heo
    Soon-Chul Choi
    Scientific Reports, 9
  • [39] ATTENUATION EQUALIZING FILTER IN DIAGNOSTIC RADIOGRAPHY - ADVANTAGES CALCULATED BY A MONTE-CARLO TECHNIQUE
    KUSOFFSKY, L
    CARLSSON, CA
    EDHOLM, P
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1976, 15 (03): : 259 - 272
  • [40] Measurements of peripheral dose for multileaf collimator based linear accelerator
    Balasubramanian, R.
    Sellakumar, P.
    Bilimagga, Ramesh S.
    Supe, Sanjay S.
    Sankar, B. N.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (06) : 281 - 285