Suture-guided sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsule rupture

被引:2
|
作者
Sethi, Harinder Singh
Naik, Mayuresh P. [1 ]
机构
[1] Safdarjang Hosp, Room 430 Eye OPD,4th Floor OPD Bldg,Ring Rd, New Delhi 110029, India
来源
关键词
CATARACT-SURGERY; PHACOEMULSIFICATION;
D O I
10.1016/j.jcrs.2017.02.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We describe a technique for suture-guided sulcus implantation of a foldable acrylic posterior chamber IOL (PC IOL). A 100 monofilament nylon suture is used to control insertion of the PC IOL over the ciliary sulcus and enable safe retrieval if the PC IOL drops during insertion, stabilization, or centration. In this technique, the 10-0 monofilament nylon suture acts as a guy rope to hold onto the PC IOL, enabling the surgeon to inject the IOL into the sulcus, unfold it in the iris plane, dial it in the appropriate meridian, and stabilize it. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:309 / 311
页数:3
相关论文
共 50 条
  • [31] Implantation of single-piece foldable acrylic IOLs in small children in the Ukraine
    Kugelberg, M
    Kugelberg, U
    Bobrova, N
    Tronina, S
    Zetterström, C
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03): : 380 - 383
  • [32] Breakage of the haptic of a single-piece acrylic intraocular lens after transscleral fixation
    Choi, Suk Kyue
    Kim, Jin Hyoung
    Lee, Doh
    Lee, Jong Hyun
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e346 - e347
  • [33] Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens
    Tanaka, Hiroki
    Fujinami, Kaoru
    Watanabe, Ken
    Noda, Toru
    Akiyama, Kunihiko
    CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 212 - 216
  • [34] Rotational stability of a single-piece toric acrylic intraocular lens
    Koshy, John J.
    Nishi, Yutaro
    Hirnschall, Nino
    Crnej, Alja
    Gangwani, Vinod
    Maurino, Vincenzo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1665 - 1670
  • [35] Simple method to evaluate adequacy of capsule for foldable intraocular lens implantation in the sulcus
    Zarei-Ghanavati, Siamak
    Gharaii, Hamid
    Zarei-Ghanavati, Mehran
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 222 - 225
  • [36] Evaluation of uveal and capsule biocompatibility of a single-piece hydrophobic acrylic intraocular lens with ultraviolet-ozone treatment on the posterior surface
    Farukhi, M. Aabid
    Werner, Liliana
    Kohl, Justin C.
    Gardiner, Gareth L.
    Ford, Joshua R.
    Cole, Scott C.
    Vasavada, Shail A.
    Noristani, Rozina
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05): : 1081 - 1087
  • [37] LONG-TERM STABILITY AND VISUAL OUTCOMES OF A SINGLE-PIECE, FOLDABLE, ACRYLIC INTRAOCULAR LENS FOR SCLERAL FIXATION
    Kim, Stephen Jae
    Lee, Sung Jin
    Park, Chang Hyun
    Jung, Gi Yong
    Park, Song Hee
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (01): : 91 - 97
  • [38] Incidence and influence of posterior capsule striae on the development of posterior capsule opacification after 1-piece hydrophobic acrylic intraocular lens implantation
    Shah, Gauri D.
    Vasavada, Abhay R.
    Praveen, Mamidipudi R.
    Shah, Alpesh R.
    Trivedi, Rupal H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 202 - 207
  • [39] Intraocular Lens Position Following In-the-Bag Implantation of Single-Piece Versus Three-Piece Acrylic Intraocular Lenses
    Robert, Marie-Claude
    Harasymowycz, Paul
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (06) : 472 - 478
  • [40] Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure
    Iwase, Takeshi
    Sugiyama, Kazuhisa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 329 - 332