Peptide Vectors Carry Pyrene to Cell Organelles Allowing Real-Time Quantification of Free Radicals in Mitochondria by Time-Resolved Fluorescence Microscopy

被引:11
|
作者
Wawi, Mohamad Jamal [1 ,2 ]
Bijoux, Amandine [1 ]
Inguimbert, Nicolas [3 ]
Mahler, Christoph [4 ,5 ]
Wagner, Stephan [4 ,5 ]
Marder, Todd B. [4 ,5 ]
Ribou, Anne-Cecile [1 ,2 ]
机构
[1] Univ Perpignan Via Domitia, Inst Modeling & Anal Geoenvironm & Hlth IMAGES ES, Bat B,52 Ave P Alduy, F-66860 Perpignan, France
[2] Univ Reunion, Univ Guyane, Univ Antilles, Univ Montpellier,ESPACE DEV,UMR 228,IRD,Maison Te, 500 Rue Jean Francois Breton, F-34093 Montpellier 5, France
[3] Univ Perpignan Via Domitia, USR 3278, CRIOBE, PSL Univ Paris EPHE UPVD CNRS, 58 Ave Paul Alduy, F-66860 Perpignan, France
[4] Julius Maximilians Univ Wurzburg, Inst Anorgan Chem, D-97074 Wurzburg, Germany
[5] Julius Maximilians Univ Wurzburg, Inst Sustainable Chem & Catalysis Boron, D-97074 Wurzburg, Germany
关键词
fluorescent probes; peptides; pyrene; reactive oxygen species; time-resolved spectroscopy; IMAGING HYDROGEN-PEROXIDE; SINGLE LIVING CELLS; REACTIVE OXYGEN; OXIDATIVE STRESS; METABOLIC-RATE; SUPEROXIDE ANION; PROBES; LIFETIME; GENERATION; ACID;
D O I
10.1002/cbic.202000845
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Real-time quantification of reactive nitrogen and oxygen species (ROS) in cells is of paramount importance as they are essential for cellular functions. Their excessive formation contributes to the dysfunction of cells and organisms, ultimately leading to cell death. As ROS are mostly produced in the mitochondria, we have synthesized a fluorescent probe able to reach this organelle to detect and quantify, in real time, the variation of ROS by time-resolved microfluorimetry. The new probes are based on the long fluorescence lifetime of pyrene butyric acid (PBA). Two PBA isomers, attached at their 1- or 2-positions to a peptide vector to target mitochondria, were compared and were shown to allow the measurement of free radical species and oxygen, but not non-radical species such as H2O2.
引用
收藏
页码:1676 / 1685
页数:10
相关论文
共 46 条
  • [1] Real-time digital signal processing in multiphoton and time-resolved microscopy
    Wilson, Jesse W.
    Warren, Warren S.
    Fischer, Martin C.
    OPTICAL BIOPSY XIV: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2016, 9703
  • [2] Real-time fluorescence lifetime-resolved images in microscopy
    Clegg, RM
    Schneider, PC
    BIOPHYSICAL JOURNAL, 1998, 74 (02) : A8 - A8
  • [3] A high sensitivity time-resolved microfluorimeter for real-time cell biology
    MartinFernandez, ML
    Tobin, MJ
    Clarke, DT
    Gregory, CM
    Jones, GR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (10): : 3716 - 3721
  • [4] REAL-TIME DETERMINATION OF DISSOLVED FREE AMINO-ACIDS AND PRIMARY AMINES IN SEAWATER BY TIME-RESOLVED FLUORESCENCE
    WING, MR
    STROMVALL, EJ
    LIEBERMAN, SH
    MARINE CHEMISTRY, 1990, 29 (04) : 325 - 338
  • [5] Time-resolved fluorometry in end-point and real-time PCR quantification of nucleic acids
    Nurmi, J
    Lilja, H
    Ylikoski, A
    LUMINESCENCE, 2000, 15 (06) : 381 - 388
  • [6] Fluorescence Dynamics in the Endoplasmic Reticulum of a Live Cell: Time-Resolved Confocal Microscopy
    Ghosh, Shirsendu
    Nandi, Somen
    Ghosh, Catherine
    Bhattacharyya, Kankan
    CHEMPHYSCHEM, 2016, 17 (18) : 2818 - 2823
  • [7] Time-Resolved Four-Tap Lock-In Pixel CMOS Image Sensor for Real-Time Fluorescence Lifetime Imaging Microscopy
    Seo, Min-Woong
    Shirakawa, Yuya
    Kawata, Yoshimasa
    Kagawa, Keiichiro
    Yasutomi, Keita
    Kawahito, Shoji
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (08) : 2319 - 2330
  • [8] Time-resolved fluorescence measurement system for real-time high-throughput microfluidic droplet sorting
    Khaddour, Wass M.
    Uhring, Wilfried
    Dadouche, Foudil
    Frick, Vincent
    Madec, Morgan
    2020 18TH IEEE INTERNATIONAL NEW CIRCUITS AND SYSTEMS CONFERENCE (NEWCAS'20), 2020, : 246 - 249
  • [9] Oxygen sensing in a single cell with ruthenium complexes and fluorescence time-resolved microscopy.
    Malak, H
    Dobrucki, JW
    Malak, MM
    Swartz, HM
    BIOPHYSICAL JOURNAL, 1998, 74 (02) : A189 - A189
  • [10] Real-Time Imaging of Free Radicals for Mitochondria-Targeting Hypoxic Tumor Therapy
    Wang, Xiao-Qiang
    Peng, Mengyun
    Li, Chu-Xin
    Zhang, Yu
    Zhang, Mingkang
    Tang, Ying
    Liu, Miao-Deng
    Xie, Bo-Ru
    Zhang, Xian-Zheng