Construction and evaluation of an ammonium tubular ion-selective electrode with ionophore nonactin.

被引:0
|
作者
Junior, LR [1 ]
Neto, GD [1 ]
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
机构
[1] UNIV PORTO, FAC FARM, DEPT QUIM FIS, P-4100 OPORTO, PORTUGAL
来源
QUIMICA NOVA | 1996年 / 19卷 / 05期
关键词
tubular electrode; ammonium determination; nonactin;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper describes the construction of an ammonium tubular potentiometric detector for flow injection analisys (FIA) in which the high molecular weight polyvinyl chloride (PVC) membrane is applied directly on a conducting support consisting of a mixture of an epoxy resin and graphite. The tubular ammonium ion-selective electrode, without internal reference solution, is based on nonactin as the ionophore and bis-(2-ethylhexyl)-adipate as plasticiser solvent, supported upon a PVC membrane, The electrode exhibited a response of 55.6 mV per concentration decade within the 5.0x10(-5) to 1.0x10(-1) mol/L NH4+ range in TRIS-HCl 0.2 mol/L (pH=6.7) buffer. Potassium ions constituted the greatest analytical interference; the electrode response time was 10 seconds, at 25.0 degrees C.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [21] DETERMINATION OF NITRATE IN WATER WITH A NEW CONSTRUCTION OF ION-SELECTIVE ELECTRODE
    HULANICKI, A
    LEWANDOWSKI, R
    MAJ, M
    ANALYTICA CHIMICA ACTA, 1974, 69 (02) : 409 - 414
  • [22] Visible and FTIR microscopic observation of bisthiourea ionophore aggregates in ion-selective electrode membranes
    Phillips, KN
    Lantz, C
    Bühlmann, P
    ELECTROANALYSIS, 2005, 17 (22) : 2019 - 2025
  • [23] EVALUATION OF AN ION-SELECTIVE ELECTRODE MONITOR FOR TOTAL OXIDANTS
    TRACHTENBERG, AF
    SUFFET, IH
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1974, 24 (09): : 836 - 840
  • [24] Tetrachlorophenylporphyrinato manganese(III) acetate as a new ionophore for a coated triiodide ion-selective electrode
    Farhadi, K
    Bonab, HS
    Maleki, R
    Shamsipur, M
    Shargi, H
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (05) : 861 - 866
  • [25] Current response of ionophore-based ion-selective electrode membranes at controlled potential
    Morf, WE
    Zwickl, T
    Pretsch, E
    de Rooij, NF
    CHIMIA, 2003, 57 (10) : 639 - 642
  • [26] Beyond Nonactin: Potentiometric Ammonium Ion Sensing Based on Ion-selective Membrane-free Prussian Blue Analogue Transducers
    Xu, Longbin
    Zhong, Lijie
    Tang, Yitian
    Han, Tingting
    Liu, Siyi
    Sun, Zhonghui
    Bao, Yu
    Wang, Haoyu
    He, Ying
    Wang, Wei
    Gan, Shiyu
    Niu, Li
    ANALYTICAL CHEMISTRY, 2022, 94 (29) : 10487 - 10496
  • [27] Determination of Thiocyanate Ion by Ion-selective Electrode Using Schiff Base Complex of Cu(II) as an Ionophore
    Singh, Sanjay
    Singh, Aishwarya
    Yadav, Kalash Chandra
    Singh, Arpit
    Singh, Gyanendra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02): : 163 - 177
  • [28] PHOSPHATE ION-SELECTIVE ELECTRODE
    TAKAISHVILI, OG
    MOTSONELIDZE, EP
    KARACHENTSEVA, YM
    DAVITAYA, PI
    SOVIET ELECTROCHEMISTRY, 1976, 12 (02): : 288 - 290
  • [29] ION-SELECTIVE ELECTRODE FOR METHYLAMINE
    HSIUNG, KP
    KUAN, SS
    GUILBAULT, GG
    ANALYTICA CHIMICA ACTA, 1976, 84 (01) : 15 - 22
  • [30] SELECTIVITY EVALUATION OF AN ION-SELECTIVE ELECTRODE WITH A LIQUID MEMBRANE BY ELECTRODE RESPONSE TO A FOREIGN ION
    JYO, A
    TORIKAI, M
    ISHIBASH.N
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1974, 47 (11) : 2862 - 2868