Construction and evaluation of an ammonium tubular ion-selective electrode with ionophore nonactin.

被引:0
|
作者
Junior, LR [1 ]
Neto, GD [1 ]
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
机构
[1] UNIV PORTO, FAC FARM, DEPT QUIM FIS, P-4100 OPORTO, PORTUGAL
来源
QUIMICA NOVA | 1996年 / 19卷 / 05期
关键词
tubular electrode; ammonium determination; nonactin;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper describes the construction of an ammonium tubular potentiometric detector for flow injection analisys (FIA) in which the high molecular weight polyvinyl chloride (PVC) membrane is applied directly on a conducting support consisting of a mixture of an epoxy resin and graphite. The tubular ammonium ion-selective electrode, without internal reference solution, is based on nonactin as the ionophore and bis-(2-ethylhexyl)-adipate as plasticiser solvent, supported upon a PVC membrane, The electrode exhibited a response of 55.6 mV per concentration decade within the 5.0x10(-5) to 1.0x10(-1) mol/L NH4+ range in TRIS-HCl 0.2 mol/L (pH=6.7) buffer. Potassium ions constituted the greatest analytical interference; the electrode response time was 10 seconds, at 25.0 degrees C.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [1] Design and synthesis of a more highly selective ammonium ionophore than nonactin and its application as an ion-sensing component for an ion-selective electrode
    Suzuki, K
    Siswanta, D
    Otsuka, T
    Amano, T
    Ikeda, T
    Hisamoto, H
    Yoshihara, R
    Ohba, S
    ANALYTICAL CHEMISTRY, 2000, 72 (10) : 2200 - 2205
  • [2] Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode
    Benco, JS
    Nienaber, HA
    McGimpsey, WG
    ANALYTICAL CHEMISTRY, 2003, 75 (01) : 152 - 156
  • [3] Construction and evaluation of a tubular ion-selective electrode for hydrogen ion as a detector in flow analysis.
    Martelli, PB
    Reis, BF
    Zagatto, EAG
    Lima, JLFC
    Lapa, RA
    QUIMICA NOVA, 1998, 21 (02): : 133 - 139
  • [4] CONSTRUCTION AND EVALUATION OF A NOVEL GLAFENINE ION-SELECTIVE ELECTRODE
    AHMED, MA
    ABBAS, AB
    ANALYTICAL LETTERS, 1995, 28 (01) : 13 - 26
  • [5] RESPONSE-TIME CURVES OF AMMONIUM ION-SELECTIVE ELECTRODE OF TUBULAR SHAPE
    DEGAWA, H
    SHINOZUKA, N
    HAYANO, S
    CHEMISTRY LETTERS, 1983, (01) : 25 - 28
  • [6] DETERMINATION OF AMMONIUM ION IN URINE USING AN AMMONIUM ION-SELECTIVE ELECTRODE
    MERKOCI, A
    COCOLI, V
    BARAJ, B
    BUZO, S
    ACTA CHIMICA HUNGARICA-MODELS IN CHEMISTRY, 1993, 130 (01): : 19 - 24
  • [7] ION-SELECTIVE ELECTRODE DETERMINATION OF AMMONIUM ION IN NATURAL AND WASTEWATERS
    TSINGARELLI, RD
    TABAKOVA, OM
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1984, 39 (08): : 1146 - 1149
  • [8] Construction and evaluation of a novel In(III) liquid ion-selective membrane electrode
    Li, CX
    Hou, JG
    TALANTA, 1997, 44 (05) : 729 - 732
  • [9] EVALUATION OF A NITRATE ION-SELECTIVE ELECTRODE
    FAYAD, NA
    TYSON, JF
    INTERNATIONAL LABORATORY, 1979, (MAR-): : 49 - &
  • [10] Salicylate Ion-Selective Electrode Based on a Calix[4]arene as Ionophore
    Ayanoglu, Melek Nur
    Erturun, H. Elif Kormali
    Ozel, Ayca Demirel
    Sahin, Ozlem
    Yilmaz, Mustafa
    Kilic, Esma
    ELECTROANALYSIS, 2015, 27 (07) : 1676 - 1684