Impact of radiation dose level on CT number accuracy in photon counting CT

被引:0
|
作者
Zhang, Ran [1 ]
Cruz-Bastida, Juan P. [1 ]
Gomez-Cardona, Daniel [1 ]
Hayes, John [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
关键词
TUBE CURRENT MODULATION; ITERATIVE RECONSTRUCTION; REDUCTION;
D O I
10.1117/12.2293907
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is well known that when radiation dose is reduced in x-ray computed tomography, image noise increases and noise induced streaks may appear. However, to quantify the accuracy of the image reconstruction, another source of error, known as the statistical bias, also needs to be considered. In the projection domain, signal bias originates in the quantum nature of the x-ray photon fluctuations as well as the nonlinear nature of the logarithmic transform used to generate line integral data. The bias in the projection domain is then propagated into the image domain through the image reconstruction process to generate CT number biases. The purpose of this work is to experimentally study the dependence of CT number bias on the radiation dose.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Can photon-counting CT improve PET/CT's quantitative accuracy?
    Hamill, Jim
    O'Doherty, Jim
    Nye, Jonathon
    Elojeimy, Saeed
    Birge, Noah
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [12] Photon-Counting Detector CT With Quantum Iterative Reconstruction Impact on Liver Lesion Detection and Radiation Dose Reduction
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Eberhard, Matthias
    Becce, Fabio
    Rotzinger, David C.
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 245 - 252
  • [13] Commentary: There is more value in photon counting detector CT for children than in radiation dose reduction
    Horst, Kelly K.
    Yu, Lifeng
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1996 - 1997
  • [14] Impact of Noise Level on the Accuracy of Automated Measurement of CT Number Linearity on ACR CT and Computational Phantoms
    Anam C.
    Amilia R.
    Naufal A.
    Sutanto H.
    Dwihapsari Y.
    Fujibuchi T.
    Dougherty G.
    Journal of Biomedical Physics and Engineering, 2023, 13 (04): : 353 - 362
  • [15] Effect of Patient Positioning on CT Number Accuracy: A Phantom Study Comparing Energy Integrating and Deep Silicon Photon Counting Detector CT
    Salyapongse, Aria M.
    Rose, Sean D.
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Toia, Giuseppe V.
    Bujila, Robert
    Yin, Zhye
    Slavic, Scott
    Szczykutowicz, Timothy P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2025, 49 (02) : 297 - 307
  • [16] Construction of a Nearly Unbiased Statistical Estimator of Sinogram to Address CT Number Bias Issues in Low-Dose Photon Counting CT
    Li, Ke
    Chen, Joshua Ray
    Feng, Mang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (06) : 1846 - 1858
  • [17] CT number calibration audit in photon radiation therapy
    Nakao, Minoru
    Ozawa, Shuichi
    Miura, Hideharu
    Yamada, Kiyoshi
    Hayata, Masahiro
    Hayashi, Kosuke
    Kawahara, Daisuke
    Nakashima, Takeo
    Ochi, Yusuke
    Okumura, Takuro
    Kunimoto, Haruhide
    Kawakubo, Atsushi
    Kusaba, Hayate
    Nozaki, Hiroshige
    Habara, Kosaku
    Tohyama, Naoki
    Nishio, Teiji
    Nakamura, Mitsuhiro
    Minemura, Toshiyuki
    Okamoto, Hiroyuki
    Ishikawa, Masayori
    Kurooka, Masahiko
    Shimizu, Hidetoshi
    Hotta, Kenji
    Saito, Masahide
    Nakano, Masahiro
    Tsuneda, Masato
    Nagata, Yasushi
    MEDICAL PHYSICS, 2024, 51 (03) : 1571 - 1582
  • [18] Accuracy of Linear Attenuation Coefficients Measured with a Photon Counting CT System
    Kobayashi, Toru
    Ogawa, Koichi
    Kaibuki, Futoshi
    Yamakawa, Tsutomu
    Nagano, Tatsuya
    Hashimoto, Daisuke
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3596 - 3599
  • [19] Research on accuracy of material identification based on photon counting spectral CT
    Zhang, Xiaomei
    Wang, Zhe
    Yun, Xiangyu
    Li, Mohan
    Hu, Jinming
    Wang, Chengmin
    Wei, Cunfeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (04) : 811 - 824
  • [20] CT Number Accuracy and Association With Object Size: A Phantom Study Comparing Energy-Integrating Detector CT and Deep Silicon Photon-Counting Detector CT
    Salyapongse, Aria M.
    Rose, Sean D.
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Toia, Giuseppe V.
    Bujila, Robert
    Yin, Zhye
    Slavic, Scott
    Szczykutowicz, Timothy P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (04) : 539 - 547