On-line control of the heat exchanger network under fouling constraints

被引:18
|
作者
Markowski, Mariusz [1 ]
Trzcinski, Przemyslaw [1 ]
机构
[1] Warsaw Univ Technol, Fac Civil Engn Mech & Petrochem, Inst Engn Mech, Lukasiewicza 17, PL-09400 Plock, Poland
关键词
Heat exchanger fouling; Heat exchanger network; On-line control of HEN; Heat recovery in HEN;
D O I
10.1016/j.energy.2019.07.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The article presents a mathematical model for on-line control of a heat exchanger network (HEN), aiming at maximization of heat recovery. The model assumes that HEN operates at steady state. The paper presents the method of processing measurement data in order to separate periods of time, which corresponds to the steady state of HEN. The existing mathematical models of the heat exchanger give an inaccurate results, due to large calculation errors in the estimation of the heat transfer coefficient (10-40%). Therefore, the authors introduced a heat exchanger model in which measurements were used to improve the correlation describing the heat transfer coefficient. The heat exchanger model with improved correlation was applied for estimation of the thermal fouling resistances. This approach allows calculating the exchanger with a much smaller calculation error (below 1%). The mathematical model and algorithm of HEN control were presented. The proposed on-line control model was tested on the example of HEN belonging to Crude Distillation Unit, processing 780 t/h of crude oil. In the proposed process control system, the manipulated variables are mass flows of crude oil flowing through HEN branches. The proposed method of HEN control gives opportunity to increase the heat recovery by 1.5%. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 50 条
  • [41] EVALUATE HEAT-EXCHANGER FOULING
    MASCONE, CF
    CHEMICAL ENGINEERING, 1984, 91 (16) : 93 - 93
  • [42] HEAT EXCHANGER FOULING WITH DUST SUSPENSIONS
    HAWES, RI
    GARTON, DA
    CHEMICAL AND PROCESS ENGINEERING, 1967, (AUG): : 143 - &
  • [43] HEAT EXCHANGER DESIGN FOR FOULING SERVICE
    KERN, DQ
    CHEMICAL ENGINEERING PROGRESS, 1966, 62 (07) : 75 - &
  • [44] On-Line Fuzzy-Logic-Based Temperature Control of a Concentric-Tube Heat Exchanger Facility
    Pacheco-Vega, Arturo
    Ruiz-Mercado, Claudia
    Peters, Kevin
    Vilchiz, Luis Enrique
    HEAT TRANSFER ENGINEERING, 2009, 30 (14) : 1208 - 1215
  • [45] On-line monitoring of ash fouling and soot-blowing optimization for convective heat exchanger in coal-fired power plant boiler
    Shi, Yuanhao
    Wang, Jingcheng
    Liu, Zhengfeng
    APPLIED THERMAL ENGINEERING, 2015, 78 : 39 - 50
  • [46] Neural network predictive control of a heat exchanger
    Vasickaninova, Anna
    Bakosova, Monika
    Meszaros, Alojz
    Klemes, Jiri
    PRES 2010: 13TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2010, 21 : 73 - 78
  • [47] Neural network predictive control of a heat exchanger
    Vasickaninova, Anna
    Bakosova, Monika
    Meszaros, Alojz
    Klemes, Jiri Jaromir
    APPLIED THERMAL ENGINEERING, 2011, 31 (13) : 2094 - 2100
  • [48] Bypass Selection for Control of Heat Exchanger Network
    Sun Lin
    Luo Xionglin
    Hou Benquan
    Bai Yujie
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2013, 21 (03) : 276 - 284
  • [49] Neural network control of heat exchanger plant
    Jalili-Kharaajoo, M
    ADVANCES IN NEURAL NETWORKS - ISNN 2005, PT 3, PROCEEDINGS, 2005, 3498 : 137 - 142
  • [50] Optimal design of heat exchanger network considering the fouling throughout the operating cycle
    Hang, Peng
    Zhao, Liwen
    Liu, Guilian
    ENERGY, 2022, 241