Three Steps Mixed (Fire Tube-Water Tube) Vertical Boiler to Optimize Thermal Performance

被引:0
|
作者
Aguilar Vizcarra, Duilio [1 ]
Esenarro, Doris [2 ]
Rodriguez, Ciro [3 ]
机构
[1] Univ Nacl Ingn UNI, Dept Mech Engn, Lima 25, Peru
[2] Univ Nacl Federico Villarreal UNFV, Dept Environm Engn, Lima 32, Peru
[3] Univ Nacl Mayor San Marcos UNMSM, Dept Software Engn, Lima 01, Peru
关键词
three-step mixed boiler; fire-water tube boiler; steam; fluid; fuel; diesel; natural gas; Liquid Petroleum Gas (LPG); PARAMAGNETIC FLUID; EFFICIENCY; CONVECTION; NANOFLUID; FLOW;
D O I
10.3390/fluids6030093
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The research aims to design and construct a new mixed vertical boiler (fire tube - water tube) with three gas passes. The strength of this technological innovation is in the best use of the thermic transmission receiving fluid (hot water, steam, thermal oil), this due to its multipurpose function of three steps using alternative fuels (Diesel, Liquid Petroleum Gas LPG, natural gas), by improving the thermal efficiency of the boiler its temperature is reduced with gases at low temperatures, which in turn also reduce environmental pollution. The methodology focuses on calculating the transfer area with the calculation method that will allow dimensioning the boiler, considering the calculation of losses and the fluid speed, with two defined procedures, the first for fire tube and water tube boilers. And another alternative. The results obtained allowed optimizing the thermal efficiency level, achieving very significant thermal efficiency results: With LPG 92.4% for hot water and 92.42% to generate steam in the same way with natural gas 90.25% for hot water and 90.24% to generate steam as well with Diesel 2; 89.21% for hot water and 89.31% to generate steam.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Failure Analysis of Boiler Water Wall Tube: A Case Study from Thermal Power Plant
    Debashis Ghosh
    Himadri Roy
    Atanu Saha
    Chidambaram Subramanian
    Journal of Failure Analysis and Prevention, 2022, 22 : 203 - 208
  • [32] Failure Analysis of Boiler Water Wall Tube: A Case Study from Thermal Power Plant
    Ghosh, Debashis
    Roy, Himadri
    Saha, Atanu
    Subramanian, Chidambaram
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (01) : 203 - 208
  • [34] Development of a Computer Model of a Fire-Tube Hot Water Boiler, Its Verification and Use in the Design Process
    Roslyakov, P. V.
    Pleshanov, K. A.
    Supranov, V. M.
    Zaichenko, M. N.
    Ionkin, I. L.
    Sterkhov, K. V.
    Grisha, B. G.
    2018 IV INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGIES IN ENGINEERING EDUCATION (INFORINO), 2018,
  • [35] Performance of U-tube solar water heater with vertical and inclined panels
    Ong, K. S.
    Tong, W. L.
    Choong, J. K.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2016, 11 (02) : 248 - 253
  • [36] Performance of Vertical Tube Passive Condenser with the Effects of Noncondensable and Secondary Cooling Water
    Revankar, Shripad T.
    Zhou, Wenzhong
    HEAT TRANSFER ENGINEERING, 2015, 36 (04) : 368 - 377
  • [37] Effect of pH Decrease in Boiler Water on the Redox Behaviors and Oxide Film Characteristics of Boiler Tube Steels in Thermal Power Plants
    Niu, Li-Bin
    Nakane, Takahiro
    Takaku, Hiroshi
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2012, 76 (03) : 203 - 209
  • [38] Effect of pH decrease in boiler water on the redox behaviors and oxide film characteristics of boiler tube steels in thermal power plants
    Niu, Li-Bin
    Nakane, Takahiro
    Takaku, Hiroshi
    Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals, 2012, 76 (03): : 203 - 209
  • [39] High performance-water tube boiler in electrical works of the city of Brandenburg a.H.
    Mahr
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1912, 56 : 1708 - 1710
  • [40] Performance of The Mini Boiler Type of Fire Tube 3 Phase using Wood Pellet and Coconut Shells as Fuels
    Hanifah, Umi
    Susanti, Novita Dwi
    Andrianto, Moeso
    AGRITECH, 2019, 39 (03): : 200 - 206