Three Steps Mixed (Fire Tube-Water Tube) Vertical Boiler to Optimize Thermal Performance

被引:0
|
作者
Aguilar Vizcarra, Duilio [1 ]
Esenarro, Doris [2 ]
Rodriguez, Ciro [3 ]
机构
[1] Univ Nacl Ingn UNI, Dept Mech Engn, Lima 25, Peru
[2] Univ Nacl Federico Villarreal UNFV, Dept Environm Engn, Lima 32, Peru
[3] Univ Nacl Mayor San Marcos UNMSM, Dept Software Engn, Lima 01, Peru
关键词
three-step mixed boiler; fire-water tube boiler; steam; fluid; fuel; diesel; natural gas; Liquid Petroleum Gas (LPG); PARAMAGNETIC FLUID; EFFICIENCY; CONVECTION; NANOFLUID; FLOW;
D O I
10.3390/fluids6030093
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The research aims to design and construct a new mixed vertical boiler (fire tube - water tube) with three gas passes. The strength of this technological innovation is in the best use of the thermic transmission receiving fluid (hot water, steam, thermal oil), this due to its multipurpose function of three steps using alternative fuels (Diesel, Liquid Petroleum Gas LPG, natural gas), by improving the thermal efficiency of the boiler its temperature is reduced with gases at low temperatures, which in turn also reduce environmental pollution. The methodology focuses on calculating the transfer area with the calculation method that will allow dimensioning the boiler, considering the calculation of losses and the fluid speed, with two defined procedures, the first for fire tube and water tube boilers. And another alternative. The results obtained allowed optimizing the thermal efficiency level, achieving very significant thermal efficiency results: With LPG 92.4% for hot water and 92.42% to generate steam in the same way with natural gas 90.25% for hot water and 90.24% to generate steam as well with Diesel 2; 89.21% for hot water and 89.31% to generate steam.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Performance Enhancement Of An Industrial Fire Tube Boiler
    Haq, M. Z. U.
    Yahya, Z.
    Masood, H. M.
    Ali, N.
    Ashraf, M.
    JOURNAL OF THE PAKISTAN INSTITUTE OF CHEMICAL ENGINEERS, 2020, 48 (01): : 43 - 48
  • [2] Benson boiler with vertical tube water walls - Principles and advantages
    Franke, J
    Kral, R
    Wittchow, E
    INTERNATIONAL CONFERENCE ON ADVANCED STEAM PLANT - NEW MATERIALS AND PLANT DESIGNS AND THEIR PRACTICAL IMPLICATIONS FOR FUTURE CCGT AND CONVENTIONAL POWER STATIONS, 1997, 1997 (02): : 143 - 153
  • [3] Design of vertical fire tube boiler using IBR code and FEA analysis
    Bhatkar, Vijay W.
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2021, 18 (11-12) : 1041 - 1050
  • [4] Thermodynamic analysis of vertical reducing helix fire tube waste heat boiler
    Institute of Clean Coal Technology, East China University of Science and Technology, Shanghai 200237, China
    Hua Dong Li Gong Da Xue/J East China Univ Sci Technol, 2008, 6 (799-804+871):
  • [5] Thermal Calculation of the Furnace Chamber of a Fire‐Tube Boiler With a Dead‐End Furnace
    M. L. German
    V. A. Borodulya
    E. F. Nogotov
    Journal of Engineering Physics and Thermophysics, 2000, 73 (6) : 1156 - 1165
  • [6] The optimization of design of fire-tube shell hot-water boiler
    Naumejko, A.V.
    Ryzhkov, A.F.
    Gofman, M.S.
    Dejnezhenko, V.I.
    Promyshlennaya Energetika, 2002, (10): : 37 - 41
  • [7] Failure Investigation of Fire-Side Water-Wall Tube Boiler
    Fatah, M. C.
    Agustiadi, D.
    Pramono, A. W.
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (05): : 242 - 248
  • [8] Retrofit of a fire-tube boiler to burn coal-water fuel
    Hale, BM
    Arnold, DW
    ENERGY SOURCES, 1997, 19 (10): : 1139 - 1151
  • [9] Fire-tube boiler test burn on coal-water fuel
    Hale, BM
    Arnold, DW
    ENERGY SOURCES, 1998, 20 (01): : 11 - 24
  • [10] Performance of a thermal storage system of the vertical tube type