A Current Limiting Method with Distortion Suppression for Stand-Alone Three-Phase Inverter

被引:0
|
作者
Zhou, Peng [1 ]
Pei, Xuejun [1 ]
Li, Yuze [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
short-circuit fault; current limiting control; current distortion; switching frequency switchover; distortion suppression; STRATEGY;
D O I
10.1109/apec39645.2020.9124153
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Current limiting control is the key to continuous power supply of inverters. The inverters are generally switched to the current limiting mode to limit the fault currents when short-circuit faults happen. However, the fault currents will be distorted seriously due to the zero-current clamping effect as analyzed in this paper. In order to limit fault currents and suppress the fault current distortion, this paper presents a novel current limiting method. In the proposed method, the hardware current limiting circuit and the software current limiting scheme can immediately limit fault currents in cooperation. The switching frequency switchover strategy can effectively mitigate the fault current distortion. The purpose of the method is to prevent power devices from being damaged, and to ensure breakers to reliably operate and effectively support the subsequent relay protection. Simulation and experimental results verify the feasibility of the proposed method.
引用
收藏
页码:2514 / 2518
页数:5
相关论文
共 50 条
  • [31] Leakage current suppression for three-phase transformerless heric photovoltaic inverter
    Guo, Xiaoqiang (gxq@ysu.edu.cn), 1600, China Machine Press (31):
  • [32] An Integrated Three-port Inverter for Stand-alone PV Applications
    Qian, Zhijun
    Abdel-Rahman, Osama
    Hu, Haibing
    Batarseh, Issa
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 1471 - 1478
  • [33] Stand-Alone Single-Phase Power Generation Employing a Three-Phase Isolated Asynchronous Generator
    Singh, Bhim
    Sharma, Shailendra
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (06) : 2414 - 2423
  • [34] Fuzzy logic approach for smooth transition between grid-connected and stand-alone modes of three-phase DG-inverter
    Hmad, Jihed
    Houari, Azeddine
    Trabelsi, Hafedh
    Machmoum, Mohamed
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 175
  • [35] A Dual-loop Lyapunov-Function-Based Approach for Three-phase Stand-alone Inverter in d-q Frame
    He, Jinsong
    Ogura, Koki
    Zhang, Xin
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS), 2019,
  • [36] A Sliding Mode Controller Based on Robust Model Reference Adaptive Proportional-integral Control for Stand-alone Three-phase Inverter
    Esmaeili, Hadi
    Asadi, Mehdi
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (03) : 668 - 678
  • [37] A Boost-Inverter-Based, Battery-Supported, Fuel-Cell Sourced Three-Phase Stand-Alone Power Supply
    Jang, Minsoo
    Agelidis, Vassilios G.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (12) : 6472 - 6480
  • [38] A Sliding Mode Controller Based on Robust Model Reference Adaptive Proportional-integral Control for Stand-alone Three-phase Inverter
    Hadi Esmaeili
    Mehdi Asadi
    JournalofModernPowerSystemsandCleanEnergy, 2021, 9 (03) : 668 - 678
  • [39] An Asymmetric Short-Circuit Fault Ride-Through Strategy Providing Current Limiting and Continuous Voltage Supply for Three-Phase Three-Wire Stand-Alone Inverters
    He, Jian
    Liu, Peng
    Liu, Bangyin
    Duan, Shanxu
    IEEE ACCESS, 2020, 8 : 211063 - 211073
  • [40] Novel method for three-phase current-source inverter
    Wu, Chunhua
    Xiao, Peng
    Wu, Hui
    Chen, Guocheng
    Zhang, Yi
    Chen, Weimin
    Cui, Kaiyong
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (07): : 78 - 82