Mid-term results of Hydroxyapatite-Coated Threaded Cup implanted without supplementary supporting screws

被引:2
|
作者
Trapotsis, Stergios J. [1 ]
Petsatodis, George E. [1 ]
Antonarakos, Petros D. [1 ]
Givissis, Panagiotis K. [1 ]
Christodoulou, Anastasios G. [1 ]
Pournaras, John D. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Gen Hosp G Papanikolaou, Dept Orthopaed, GR-54006 Thessaloniki, Greece
关键词
Total hip arthroplasty; Acetabulum; Threaded cup; Hydroxyapatite coating; TOTAL HIP-REPLACEMENT; FOLLOW-UP; ACETABULAR COMPONENTS; ARTHROPLASTY; MIGRATION; OSTEOLYSIS; DESIGN;
D O I
10.1177/112070000901900204
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We retrospectively reviewed the clinical, radiographic, and survivorship outcomes in a series of 180 patients that underwent 204 primary Total Hip Arthroplasties with the use of a second generation threaded hydroxyapatite-coated acetabular cup that was implanted without any supplementary supporting screws. At an average follow-up period of 10.2 (range: 8-14) years, one hundred and seventy-four patients (198 cups) were available for assessment. All patients underwent detailed physical and radiographic examination; their functional status was evaluated according to the Harris Hip Score (HHS). Following their digitization, all radiographs were further reviewed in order to determine the existence of any migration of the acetabular cup. Osteolytic lesions, radiolucent lines or zones of increased bone density were also recorded and classified according to the system of DeLee & Charnley. The modified Engh's criteria were used in order to evaluate the stability of the prosthesis. The patients' mean HHS at their latest follow-up visit (97.24 points) was statistically significantly better than the preoperative mean score of 40.31 points (p<0.001). Radiographic analysis showed "stable with bone ingrowth" fixation (modified Engh's criteria) of all implants with no significant migration of the cup (mean cranial migration: 0.597 mm, mean horizontal migration: 0.607 mm, mean observed difference of the cup's inclination angle: 0.26 degrees). No areas of significant osteolysis were found. The cumulative survival rate of the implants was 97.05%. Our results suggest that second generation hydroxyapatite-coated threaded acetabular cups can be successfully implanted (and achieve excellent results) without the use of any supplementary supporting screws. (Hip International 2009; 19: 102-8)
引用
收藏
页码:102 / 108
页数:7
相关论文
共 50 条
  • [21] Mid-term results of ceramic-on-ceramic total hip arthroplasty with sandwich cup
    Hasegawa, M
    Sudo, A
    Uchida, A
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1357 - 1360
  • [22] Mid-term results of autologous chondrocyte transplantation with and without carrier matrices
    Schewe, B.
    Fritz, J.
    Jansen, P.
    Weise, K.
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (04) : 252 - 257
  • [23] Acute/mid-term results of Drug Coated Balloon following Rotational Atherectomy
    Nagai, Taito
    Nishiura, Takashi
    Hirano, Shojiro
    Koike, Junpei
    Iwasaki, Yoshihiro
    Takahashi, Tomonori
    Tokimasa, Satoshi
    Yoshida, Ritsu
    Mizobuchi, Masahiro
    Funatsu, Atsushi
    Tomoko, Kobayashi
    Nakamura, Shigeru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B260 - B261
  • [24] Hydroxyapatite-Coated Screws Versus Titanium Triangular Dowels for Sacroiliac Joint Fusion: Results From a Nonrandomized Prospective Outcome Study
    Agarwal, Rishi
    Moreau, Joshua Lee
    Mohanty, Khitish
    WORLD NEUROSURGERY, 2024, 184 : e367 - e373
  • [25] Acute and Mid-term Results of Drug-coated Balloon Following Rotational Atherectomy
    Nagai, Taito
    Funatsu, Atsushi
    Kobayashi, Tomoko
    Nakamura, Shigeru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S35 - S35
  • [26] Tibial implants: biomechanical and histomorphometric studies of hydroxyapatite-coated and uncoated stainless steel and titanium screws in long-term ovariectomized sheep
    Rocca, M
    Fini, M
    Giavaresi, G
    Aldini, NN
    Giardino, R
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (09): : 649 - 654
  • [27] Mid-term clinical results of the cementless R3 cup and Polarstem total hip arthroplasty
    Assaf, Ali
    Manara, Jonathan R.
    Teoh, Kar H.
    Evans, Aled R.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (04): : 827 - 833
  • [28] Good mid-term clinical results of a cemented dual mobility cup: a single-centre experience
    Kavcic, Gregor
    Mirt, Pika
    Bedencic, Klemen
    HIP INTERNATIONAL, 2018, 28 (01) : 59 - 62
  • [29] Mid-term clinical results of the cementless R3 cup and Polarstem total hip arthroplasty
    Ali Assaf
    Jonathan R. Manara
    Kar H. Teoh
    Aled R. Evans
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 827 - 833
  • [30] Promising Mid-term Results With a Cup-cage Construct for Large Acetabular Defects and Pelvic Discontinuity
    Amenabar, Tomas
    Rahman, Wael A.
    Hetaimish, Bandar M.
    Kuzyk, Paul R.
    Safir, Oleg A.
    Gross, Allan E.