Diagnostic Confidence and Feasibility of a Deep Learning Accelerated HASTE Sequence of the Abdomen in a Single Breath-Hold

被引:71
|
作者
Herrmann, Judith [1 ]
Gassenmaier, Sebastian [1 ]
Nickel, Dominik [2 ]
Arberet, Simon [3 ]
Afat, Saif [1 ]
Lingg, Andreas [1 ]
Kundel, Matthias [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Siemens Med Solut USA Inc, Digital Technol & Innovat, Princeton, NJ USA
关键词
magnetic resonance imaging; deep learning reconstruction; image processing; diagnostic imaging; neoplasm staging;
D O I
10.1097/RLI.0000000000000743
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to evaluate the feasibility of a single breath-hold fast half-Fourier single-shot turbo spin echo (HASTE) sequence using a deep learning reconstruction (HASTE(DL)) for T2-weighted magnetic resonance imaging of the abdomen as compared with 2 standard T2-weighted imaging sequences (HASTE and BLADE). Materials and Methods Sixty-six patients who underwent 1.5-T liver magnetic resonance imaging were included in this monocentric, retrospective study. The following T2-weighted sequences in axial orientation and using spectral fat suppression were compared: a conventional respiratory-triggered BLADE sequence (time of acquisition [TA] = 4:00 minutes), a conventional multiple breath-hold HASTE sequence (HASTE(S)) (TA = 1:30 minutes), as well as a single breath-hold HASTE with deep learning reconstruction (HASTE(DL)) (TA = 0:16 minutes). Two radiologists assessed the 3 sequences regarding overall image quality, noise, sharpness, diagnostic confidence, and lesion detectability as well as lesion characterization using a Likert scale ranging from 1 to 4 with 4 being the best. Comparative analyses were conducted to assess the differences between the 3 sequences. Results HASTE(DL) was successfully acquired in all patients. Overall image quality for HASTE(DL) was rated as good (median, 3; interquartile range, 3-4) and was significantly superior to HASTE(s) (P < 0.001) and inferior to BLADE (P = 0.001). Noise, sharpness, and artifacts for HASTE(DL) reached similar levels to BLADE (P <= 0.176) and were significantly superior to HASTE(s) (P < 0.001). Diagnostic confidence for HASTE(DL) was rated excellent by both readers and significantly superior to HASTE(s) (P < 0.001) and inferior to BLADE (P = 0.044). Lesion detectability and lesion characterization for HASTE(DL) reached similar levels to those of BLADE (P <= 0.523) and were significantly superior to HASTE(s) (P < 0.001). Concerning the number of detected lesions and the measured diameter of the largest lesion, no significant differences were found comparing BLADE, HASTE(S), and HASTE(DL) (P <= 0.912). Conclusions The single breath-hold HASTE(DL) is feasible and yields comparable image quality and diagnostic confidence to standard T2-weighted TSE BLADE and may therefore allow for a remarkable time saving in abdominal imaging.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [41] Deep inspiration breath-hold in left-sided breast radiotherapy or not?: decision based on a single CT-slice
    Petillion, S.
    Verhoeven, K.
    Van den Heuvel, F.
    Weltens, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S510 - S511
  • [42] Rapid 3D breath-hold MR cholangiopancreatography using deep learning–constrained compressed sensing reconstruction
    Yu Zhang
    Wanlin Peng
    Yi Xiao
    Yue Ming
    Kehang Ma
    Sixian Hu
    Wen Zeng
    Lingming Zeng
    Zejun Liang
    Xiaoyong Zhang
    Chunchao Xia
    Zhenlin Li
    European Radiology, 2023, 33 : 2500 - 2509
  • [43] Analysis of a Deep Learning-Based Superresolution Algorithm Tailored to Partial Fourier Gradient Echo Sequences of the Abdomen at 1.5 T Reduction of Breath-Hold Time and Improvement of Image Quality
    Afat, Saif
    Wessling, Daniel
    Afat, Carmen
    Nickel, Dominik
    Arberet, Simon
    Herrmann, Judith
    Othman, Ahmed E.
    Gassenmaier, Sebastian
    INVESTIGATIVE RADIOLOGY, 2022, 57 (03) : 157 - 162
  • [44] Deep inspiration breath-hold decreases dose to the left ventricle with whole breast or accelerated partial breast radiotherapy for left sided breast cancers
    Jarvis, L. A.
    Loo, B.
    Chang, W.
    Thorndyke, B.
    Maxim, P.
    Horst, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S179 - S179
  • [45] Reduction in cardiac and lung doses with deep inspiration breath-hold for left-sided breast cancers treated with accelerated partial breast radiotherapy
    Kim, P. J.
    Gee, H.
    Anooshfar, S.
    Yang, L. X.
    Rounsaville, M. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S524 - S524
  • [46] Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction
    Zhang, Yu
    Peng, Wanlin
    Xiao, Yi
    Ming, Yue
    Ma, Kehang
    Hu, Sixian
    Zeng, Wen
    Zeng, Lingming
    Liang, Zejun
    Zhang, Xiaoyong
    Xia, Chunchao
    Li, Zhenlin
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2500 - 2509
  • [47] Feasibility Study of Deep Inspiration Breath-Hold Based Volumetric Modulated Arc Therapy for Locally Advanced Left Sided Breast Cancer Patients
    Swamy, Shanmugam Thirumalai
    Radha, Chandrasekaran Anu
    Kathirvel, Murugesan
    Arun, Gandhi
    Subramanian, Shanmuga
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (20) : 9033 - 9038
  • [48] Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors
    Kim, YK
    Kim, CS
    Chung, GH
    Bin Jeon, S
    Lee, JM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 497 - 504
  • [49] Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging
    Van Hoe, L
    De Jaegere, T
    Bosmans, H
    Stockx, L
    Vanbeckevoort, D
    Oyen, R
    Fagard, R
    Marchal, G
    RADIOLOGY, 2000, 214 (01) : 149 - 156
  • [50] Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS
    Feng, Li
    Otazo, Ricardo
    Jung, Hong
    Jensen, Jens H.
    Ye, Jong C.
    Sodickson, Daniel K.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1661 - 1669