Diagnostic Confidence and Feasibility of a Deep Learning Accelerated HASTE Sequence of the Abdomen in a Single Breath-Hold

被引:71
|
作者
Herrmann, Judith [1 ]
Gassenmaier, Sebastian [1 ]
Nickel, Dominik [2 ]
Arberet, Simon [3 ]
Afat, Saif [1 ]
Lingg, Andreas [1 ]
Kundel, Matthias [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Siemens Med Solut USA Inc, Digital Technol & Innovat, Princeton, NJ USA
关键词
magnetic resonance imaging; deep learning reconstruction; image processing; diagnostic imaging; neoplasm staging;
D O I
10.1097/RLI.0000000000000743
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to evaluate the feasibility of a single breath-hold fast half-Fourier single-shot turbo spin echo (HASTE) sequence using a deep learning reconstruction (HASTE(DL)) for T2-weighted magnetic resonance imaging of the abdomen as compared with 2 standard T2-weighted imaging sequences (HASTE and BLADE). Materials and Methods Sixty-six patients who underwent 1.5-T liver magnetic resonance imaging were included in this monocentric, retrospective study. The following T2-weighted sequences in axial orientation and using spectral fat suppression were compared: a conventional respiratory-triggered BLADE sequence (time of acquisition [TA] = 4:00 minutes), a conventional multiple breath-hold HASTE sequence (HASTE(S)) (TA = 1:30 minutes), as well as a single breath-hold HASTE with deep learning reconstruction (HASTE(DL)) (TA = 0:16 minutes). Two radiologists assessed the 3 sequences regarding overall image quality, noise, sharpness, diagnostic confidence, and lesion detectability as well as lesion characterization using a Likert scale ranging from 1 to 4 with 4 being the best. Comparative analyses were conducted to assess the differences between the 3 sequences. Results HASTE(DL) was successfully acquired in all patients. Overall image quality for HASTE(DL) was rated as good (median, 3; interquartile range, 3-4) and was significantly superior to HASTE(s) (P < 0.001) and inferior to BLADE (P = 0.001). Noise, sharpness, and artifacts for HASTE(DL) reached similar levels to BLADE (P <= 0.176) and were significantly superior to HASTE(s) (P < 0.001). Diagnostic confidence for HASTE(DL) was rated excellent by both readers and significantly superior to HASTE(s) (P < 0.001) and inferior to BLADE (P = 0.044). Lesion detectability and lesion characterization for HASTE(DL) reached similar levels to those of BLADE (P <= 0.523) and were significantly superior to HASTE(s) (P < 0.001). Concerning the number of detected lesions and the measured diameter of the largest lesion, no significant differences were found comparing BLADE, HASTE(S), and HASTE(DL) (P <= 0.912). Conclusions The single breath-hold HASTE(DL) is feasible and yields comparable image quality and diagnostic confidence to standard T2-weighted TSE BLADE and may therefore allow for a remarkable time saving in abdominal imaging.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [1] Fast MR imaging of focal hepatic lesions: Comparison of breath-hold turbo SE, breath-hold HASTE, and breath-hold HASTE STIR versus conventional T2-weighted SE sequence
    Lee, M
    Jeong, YK
    Han, D
    Seo, DJ
    Auh, YH
    Chien, D
    RADIOLOGY, 1996, 201 : 435 - 435
  • [2] Single breath-hold diffusion-weighted imaging of the abdomen
    Chow, LC
    Bammer, R
    Moseley, ME
    Sommer, FG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) : 377 - 382
  • [3] Fast T2-weighted liver MRI: Image quality and solid focal lesions conspicuity using a deep learning accelerated single breath-hold HASTE fat-suppressed sequence
    Mule, Sebastien
    Kharrat, Rym
    Zerbib, Pierre
    Massire, Aurelien
    Nickel, Marcel Dominik
    Ambarki, Khalid
    Reizine, Edouard
    Baranes, Laurence
    Zegai, Benhalima
    Pigneur, Frederic
    Kobeiter, Hicham
    Luciani, Alain
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (10) : 479 - 485
  • [4] Breath-hold MR cholangiopancreatography using a HASTE sequence: Comparison of single-slice and multislice acquisition techniques
    Ernst, O
    Calvo, M
    Sergent, G
    Mizrahi, D
    Carpentier, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1304 - 1306
  • [5] Comprehensive Clinical Evaluation of a Deep Learning-Accelerated, Single-Breath-Hold Abdominal HASTE at 1.5 T and 3 T
    Herrmann, Judith
    Wessling, Daniel
    Nickel, Dominik
    Arberet, Simon
    Almansour, Haidara
    Afat, Carmen
    Afat, Saif
    Gassenmaier, Sebastian
    Othman, Ahmed E.
    ACADEMIC RADIOLOGY, 2023, 30 (01) : 93 - 102
  • [6] The Feasibility of Implementing Deep Inspiration Breath-Hold for Pediatric Radiation Therapy
    Lundgaard, Anni Young
    Josipovic, Mirjana
    Rechner, Laura Ann
    Bidstrup, Pernille Envold
    Hansen, Rune
    Damkjaer, Sidsel Skov
    Joergensen, Morten
    Safwat, Akmal
    Specht, Lena
    Hjalgrim, Lisa Lyngsie
    Maraldo, Maja Vestmoe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 977 - 984
  • [7] The Feasibility of Deep Inspiration Breath-Hold in Children: Results of the TEDDI Pilot Study
    Maraldo, M. V.
    Lundgaard, A. Y.
    Josipovic, M.
    Bidstrup, P. E.
    Rechner, L.
    Hansen, R.
    Damkjaer, S.
    Jorgensen, M.
    Safwat, A.
    Specht, L.
    Hjalgrim, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E278 - E278
  • [8] Development and Evaluation of Deep Learning-Accelerated Single-Breath-Hold Abdominal HASTE at 3 T Using Variable Refocusing Flip Angles
    Herrmann, Judith
    Nickel, Dominik
    Mugler, John P.
    Arberet, Simon
    Gassenmaier, Sebastian
    Afat, Saif
    Nikolaou, Konstantin
    Othman, Ahmed E.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 645 - 652
  • [9] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14
  • [10] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Makowski, Marcus R.
    Wiethoff, Andrea J.
    Jansen, Christian H. P.
    Uribe, Sergio
    Parish, Victoria
    Schuster, Andreas
    Botnar, Rene M.
    Bell, Aaron
    Kiesewetter, Christoph
    Razavi, Reza
    Schaeffter, Tobias
    Greil, Gerald F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14