Incorporation of Harmonic Injection in an Interleaved Flyback Inverter for the Implementation of an Active Anti-Islanding Technique

被引:49
|
作者
Voglitsis, Dionisis [1 ]
Papanikolaou, Nick [1 ]
Kyritsis, Anastasios Ch. [2 ]
机构
[1] Democritus Univ Thrace, Dept Elect & Comp Engn, Lab Elect Machines, GR-67100 Xanthi, Greece
[2] Ctr Renewable Energy Sources, Dept PV Syst & DER, Pikermi 19009, Greece
关键词
DC-AC power conversion; harmonic analysis; inverters; micro-inverter; module-incorporated inverter (MIC); photovoltaic power systems; SINGLE-STAGE MICROINVERTER; CONVERTER; EFFICIENCY;
D O I
10.1109/TPEL.2016.2646419
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Over recent years, the output power of microinverters [ module-incorporated inverter (MIC)] is progressively pushed to higher levels, following the current photovoltaic (PV) modules market trends. The interleaved Flyback inverter-under discontinuous conduction mode of operation (DCM)-is an appealing solution for PV applications which are based on MIC technology. This topology provides increased power level for distributed PV generation exploitation with simple control configuration, high efficiency, and reduced filter size. In this paper, the harmonic injection capability is incorporated into the interleaved Flyback inverter for the implementation of an active anti-islanding scheme. A suitable technical solution is proposed that bypasses the unfolding H-bridge, without affecting the active power generation of the inverter and without requiring any hardware modification. In addition, a mathematical model based on the instantaneous power balance theory is presented, being a powerful analysis tool for inverters operating under complete magnetic discharge such as the Flyback inverter (either conventional or interleaved) under DCM or boundary conduction mode of operation. The proposed model predicts accurately the steady-state operational behavior of the Fly-back inverter under current harmonic injection, either in grid-tied or islanding operation. The proposed technical implementation method and mathematical model are verified through simulation and experimental results. Finally, an anti-islanding set-up based on the proposed harmonic injection technique is presented and implemented into the Flybackmicro-inverter. The proposed set-up is verified through experimental results on various quality factor values, as well as for weak grid conditions.
引用
收藏
页码:8526 / 8543
页数:18
相关论文
共 50 条
  • [41] Reactive and harmonic compensation based on interleaved flyback type photovoltaic micro-inverter
    Chen, Chuanrui
    Mu, Longhua
    Zhu, Guofeng
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (05): : 51 - 57
  • [42] A Reliable Single Stage Single Phase Hybrid Solar Inverter with Anti-islanding Protection
    Arya, Jalaj
    Saini, Lalit Mohan
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [43] Frequency-Shift Acceleration Control for Anti-Islanding of a Distributed-Generation Inverter
    Kim, Seul-Ki
    Jeon, Jin-Hong
    Ahn, Jong-Bo
    Lee, Byongjun
    Kwon, Sae-Hyuk
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (02) : 494 - 504
  • [44] A Micro Inverter Based on Cuk Converter for PV Modules with Anti-Islanding and MPPT Schemes
    Cabral, Henrique G.
    Guisso, Igor L.
    de Faria, Paulo F. S. R.
    Rambo, Carlos E. B.
    dos Reis, Fernando B.
    Vanderlei Jr, A. V.
    Nery, Eduardo G.
    Viero, Renan C.
    Pan, Aline C.
    dos Reis, Fernando S.
    2016 12TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2016,
  • [45] Field Verification of an Autonomous Anti-Islanding Scheme of a Microturbine Inverter-Based Generator
    Nassif, Alexandre B.
    Torquato, Ricardo
    Said, Humud
    Lang, Daniel
    2019 IEEE/IAS 55TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2019, : 120 - 124
  • [46] Design of Frequency Shift Acceleration Control for Anti-islanding of an Inverter-based DG
    Kim, Seul-Ki
    Jeon, Jin-Hong
    Choi, Heung-Kwan
    Ahn, Jonng-Bo
    2008 13TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-5, 2008, : 2524 - 2529
  • [47] An active islanding detection technique for current controlled inverter
    Rani, B. Indu
    Srikanth, M.
    Ilango, G. Saravana
    Nagamani, C.
    RENEWABLE ENERGY, 2013, 51 : 189 - 196
  • [48] Development of grid-interconnection inverter with an islanding detection function by synchronized injection of harmonic active signal
    Nunomura, Naoto
    Yoshida, Yoshiaki
    Suzuki, Hirokazu
    ELECTRICAL ENGINEERING IN JAPAN, 2019, 206 (04) : 36 - 44
  • [49] A Performance Analysis of Active Anti-Islanding Methods Based on Frequency Drift
    Resende, Enio C.
    Carvalho, Henrique T. M.
    Melo, Fernando C.
    Coelho, Ernane A. A.
    de Lima, Gustavo B.
    de Freitas, Luiz C. G.
    2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
  • [50] Design of dq-based Voltage Positive Feedback for Anti-islanding of a DG inverter
    Kim, Seul-Ki
    Jeon, Jin-Hong
    Choi, Heung-Kwan
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 407 - 410