Operation and maintenance field experience with photovoltaic water pumping systems

被引:0
|
作者
Moore, Larry [1 ]
Post, Hal [1 ]
Adams, Krista [1 ]
Malczynski, Len [1 ]
Hauck, Randy [1 ]
Jesperson, Tom [1 ]
Skinner, Rolland [1 ]
Anderson, Jerry [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
来源
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an assessment of the failure modes, operation and maintenance (O&M) costs, and system lifecycle costs for 77 photovoltaic (PV) water pumping systems installed during a fourteen year period from 1990 to 2004. These systems were supplied, installed, operated and maintained through a customer lease program by two rural utilities, Northwest Rural Public Power District in Nebraska and Verendrye Electric Cooperative in North Dakota. Field records have been tracked and analyzed to capture maintenance events, component failure experience, repair/replacement costs and installation cost histories. The results of these analyses including annual O&M cost, failure rates, and economic comparisons with grid extension options are presented and discussed.
引用
收藏
页码:509 / 513
页数:5
相关论文
共 50 条
  • [41] Performance of photovoltaic water pumping systems under the influence of panel cooling
    Mohanraj, M.
    Chandramohan, P.
    Sakthivel, M.
    Sopian, Kamaruzzaman
    RENEWABLE ENERGY FOCUS, 2019, 31 : 31 - 44
  • [42] Sizing of on-grid photovoltaic systems for water pumping in irrigation communities
    Bayod-Rújula A.A.
    Dufo-López R.
    Gracia A.M.
    Renewable Energy and Power Quality Journal, 2023, 21 : 81 - 84
  • [43] Deign of Photovoltaic Water Pumping Systems at Minimum Cost for Palestine: A Review
    Khatib T.
    Journal of Applied Sciences, 2010, 10 (22) : 2773 - 2784
  • [44] Optimal grassland locations for sustainable photovoltaic water pumping systems in China
    Campana, Pietro Elia
    Leduc, Sylvain
    Kim, Moonil
    Liu, Junguo
    Kraxner, Florian
    McCallum, Ian
    Li, Hailong
    Yan, Jinyue
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 301 - 307
  • [45] Effect of irradiance data on the optimal sizing of photovoltaic water pumping systems
    Meunier, Simon
    Queval, Loic
    Heinrich, Matthias
    de la Fresnaye, Elvire A.
    Cherni, Judith A.
    Vido, Lionel
    Darga, Arouna
    Dessante, Philippe
    Multon, Bernard
    Kitanidis, Peter K.
    Marchand, Claude
    2019 IEEE 46TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2019, : 653 - 658
  • [46] Assessment of factors influencing the sustainable performance of photovoltaic water pumping systems
    Hadwan, Morshed
    Alkholidi, Abdulsalam
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 92 : 307 - 318
  • [47] Modelling and Optimal Sizing of Photovoltaic Water Pumping Systems - Sensitivity Analysis
    Meunier, Simon
    Queval, Loic
    Darga, Arouna
    Dessante, Philippe
    Marchand, Claude
    Heinrich, Matthias
    Cherni, Judith A.
    de la Fresnaye, Elvire A.
    Vido, Lionel
    Multon, Bernard
    Kitanidis, Peter K.
    2019 FOURTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2019,
  • [48] Real-time performance models for photovoltaic water pumping systems
    Mahjoubi, Ammar
    Mechlouch, Ridha Fethi
    Mahdhaoui, Belgacem
    Ben Brahim, Ammar
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2015, 36 (05) : 210 - 224
  • [50] Sensitivity analysis for photovoltaic water pumping systems: Energetic and economic studies
    Yahyaoui, Imene
    Atieh, Ahmad
    Serna, Alvaro
    Tadeo, Fernando
    ENERGY CONVERSION AND MANAGEMENT, 2017, 135 : 402 - 415