On-line novelty detection for artefact identification in automatic anaesthesia record keeping

被引:6
|
作者
Hoare, SW [1 ]
Asbridge, D [1 ]
Beatty, PCW [1 ]
机构
[1] Univ Manchester, Div Imaging Sci & Biomed Engn, Manchester M13 9PT, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
artefact identification; novelty detection; intelligent filtering;
D O I
10.1016/S1350-4533(02)00146-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report the design of a kernel-based on-line novelty detector (ADDaM - Automatic Dynamic Data Mapper) and its use in the detection of artefacts in an automatic anaesthesia record keeper (AARK). ADDaM produces a partitioned history of any ordered data stream and constructs a probability distribution function (PDF) from that history using Gaussian kernels. Two forms of PDF are possible: a static PDF where the prior probability of each kernel is determined by the number of observations it represents and a temporal PDF where more recent observations have a higher prior probability. Testing against the current PDF assesses the novelty of the next point entering the stream. The performance of this method for artefact detection in heart rate data was compared to Kalman, ARIMA and moving mean filters using receiver operator characteristic (ROC) curves. Performance was measured using the area under the curves (AUC), and the false positive rate (FPR) and positive predictive value (PPV) calculated at the optimal cost-point on the curves. The results obtained were: ADDaM (Static PDF) AUC 0.92, FPR 0.12, PPV 0.12 and ADDaM (Temporal PDF) AUC 0.97, FPR 0.12, PPV 0.15. Both ADDaM-based methods out performed all other on-line methods tested. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:673 / 681
页数:9
相关论文
共 50 条
  • [41] On-line process identification using the Laguerre series for automatic tuning of the proportional-integral-derivative controller
    Park, HI
    Sung, SW
    Lee, IB
    Lee, J
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1997, 36 (01) : 101 - 111
  • [42] On-line Failure Detection and Identification (FDI) and Adaptive Reconfigurable Control (ARC) in aerospace applications
    Boskovic, JD
    Li, SM
    Mehra, RK
    PROCEEDINGS OF THE 2001 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2001, : 2625 - 2626
  • [43] Design of High-power LED Automatic Dimming System for Light Source of On-line Detection System
    He, Xiangyan
    Wang, Huanyou
    Cao, Juying
    Lei, Dajun
    PROCEEDINGS OF 2020 IEEE 5TH INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC 2020), 2020, : 1487 - 1491
  • [44] On-line automatic detection of human activity in home using wavelet and hidden Markov models scilab toolkits
    Al-ani, Tarik
    Le Ba, Quynh Trang
    Monacelli, Eric
    PROCEEDINGS OF THE 2007 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1-3, 2007, : 756 - +
  • [45] Automatic microgravimetric determination of fats in milk products by use of supercritical fluid extraction with on-line piezoelectric detection
    Manganiello, L
    Ríos, A
    Valcárcel, M
    JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (02) : 265 - 274
  • [46] Real-time, automatic detection of a small biomolecule using the novel portable on-line biomolecules analyzer
    Wang Chun-Yan
    Xiong Jiang-Hui
    Tan Ying-Jun
    Yang Tang-Bin
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 569 - 572
  • [47] On-line integration of structural identification/damage detection and structural reliability evaluation of stochastic building structures
    Lei, Ying
    Wang, Longfei
    Lu, Lanxin
    Xia, Dandan
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 63 (06) : 789 - 797
  • [48] 250 m2 ..... every day! On-line detection, identification and visualization of defects in nonwovens
    250 Millionen qm .... jeden Tag! Über Online-Erkennung, -Identifizierung und -Visualisierung von Vliesstofffehlern
    Jaaskelainen, M., 2005, dpw-Verlagsgesellschaft MbH
  • [49] Automatic Electronic Tongue for On-Line Detection and Quantification of Organophosphorus and Carbamate Pesticides Using Enzymatic Screen Printed Biosensors
    Alonso, Gustavo A.
    Munoz, Roberto
    Marty, Jean-Louis
    ANALYTICAL LETTERS, 2013, 46 (11) : 1743 - 1757
  • [50] Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)
    Nederveen, A
    Lagendijk, J
    Hofman, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (05): : 1435 - 1442