Predicting the effects of knee focal articular surface injury with a patient-specific finite element model

被引:38
|
作者
Papaioannou, George [1 ]
Demetropoulos, Constantine K. [2 ]
King, Yang H. [3 ]
机构
[1] Univ Wisconsin Milwaukee, Wisconsin Inst Biomed Hlth Technol, MOVE Ctr, Milwaukee, WI 53201 USA
[2] William Beaumont Hosp, Dept Orthopaed Surg, Royal Oak, MI 48072 USA
[3] Wayne State Univ, Ctr Bioengn, Detroit, MI USA
来源
KNEE | 2010年 / 17卷 / 01期
关键词
Osteochondral defects; Knee contact pressure; Computer aided design; Finite element modeling; CARTILAGE; REPAIR; SIZE;
D O I
10.1016/j.knee.2009.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Successful focal articular surface injury (FAI) repair depends on appropriate matching of the geometrical/material properties of the repaired site, and on the overall dynamic response of the knee to in-vivo loading. There is evidence linking the pathogenesis of lesion progression (e.g. osteoarthritis) to weightbearing site and defect size. The paper investigates further this link by studying the effects of osteochondral defect size on the load distribution at the human knee. Experimental data from cadaver knees (n = 8) loaded at 30 degrees of flexion Was used as input to a validated finite element (FE) model. Contact pressure was assessed for the intact knees and over a range of circular osteochondral defects (5 mill to 20 mm) at 30 degrees of flexion with 700 N axial load. Patient specific FE models and the specific boundary conditions of the experimental set-Lip were used to analyze the osteochondral defects. Stress concentration around the rims of defects 8 mm and smaller was not significant and pressure distribution was dominated by the menisci. Experimental data was confirmed by the model. For defects 10 mm and greater, distribution of peak pressures followed the rim of the defect with a mean distance from the rim of 2.64 mill oil the medial condyle and 2.90 mill on the lateral condyle (model predictions were 2.63 and 2.87 man respectively). Statistical significance was reported when comparing defects that differed by 4 mm or greater (except for the 5 mm case). Peak rim pressure did not significantly increase as defects were enlarged from 10 mm to 20 mm. Peak Values were always significantly higher over the medial femoral condyle. Although the decision to treat osteochondral lesions is multifactorial, the results Of this finite element analysis indicate that a size threshold of 10 mm, may be a useful early adjunct to guide clinical decision-making. This modified FE method can be employed for in-vivo studies. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 50 条
  • [41] Towards Patient-Specific Finite-Element Simulation of MitralClip Procedure
    Mansi, T.
    Voigt, I.
    Mengue, E. Assoumou
    Ionasec, R.
    Georgescu, B.
    Noack, T.
    Seeburger, J.
    Comaniciu, D.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 452 - +
  • [42] Patient-Specific Finite Element Analysis of Ascending Thoracic Aortic Aneurysm
    Wisneski, Andrew D.
    Mookhoek, Aart
    Chitsaz, Sam
    Hope, Michael D.
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (06): : 765 - 772
  • [43] Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation
    Thuy Pham
    Fanwei Kong
    Caitlin Martin
    Qian Wang
    Charles Primiano
    Raymond McKay
    John Elefteriades
    Wei Sun
    Cardiovascular Engineering and Technology, 2017, 8 : 3 - 16
  • [44] Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design
    Rodrigues, Monise de Paula
    Ferreira Soares, Priscilla Barbosa
    Correia Miranda Valdivia, Andrea Dollores
    Pessoa, Roberto Sales
    Verissimo, Crisnicaw
    Versluis, Antheunis
    Soares, Carlos Jose
    JOURNAL OF ENDODONTICS, 2017, 43 (09) : 1539 - 1544
  • [45] Finite element analysis of patient-specific additive-manufactured implants
    Namvar, Arman
    Lozanovski, Bill
    Downing, David
    Williamson, Tom
    Kastrati, Endri
    Shidid, Darpan
    Hill, David
    Buehner, Ulrich
    Ryan, Stewart
    Choong, Peter F.
    Sanaei, Reza
    Leary, Martin
    Brandt, Milan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [46] Finite Element Modelling of Stent Deployment in a Patient-specific Coronary Artery
    He, Ran
    Zhao, Liguo
    Silberschmidt, Vadim V.
    Liu, Yang
    Vogt, Felix
    INTERNATIONAL CONFERENCE ON STENTS: MATERIALS, MECHANICS AND MANUFACTURING (ICS3M 2019), 2019, 15 : 28 - 32
  • [47] Finite Element Analysis of Patient-Specific Femur Bone for Synthetic Biomaterials
    Khare, Navneet
    Sharma, Gorang
    Modi, Yashwant Kumar
    ADVANCES IN MECHANICAL ENGINEERING, ICRIDME 2018, 2020, : 649 - 659
  • [48] Patient-specific finite element analysis of femurs with cemented hip implants
    Katz, Yekutiel
    Lubovsky, Omri
    Yosibash, Zohar
    CLINICAL BIOMECHANICS, 2018, 58 : 74 - 89
  • [49] PATIENT-SPECIFIC FINITE ELEMENT MODELING OF MITRAL VALVE DYNAMIC DEFORMATION
    Wang, Qian
    Sun, Wei
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 225 - 226
  • [50] Validating Patient-Specific Finite Element Models of Direct Electrocortical Stimulation
    Charlebois, Chantel M.
    Caldwell, David J.
    Rampersad, Sumientra M.
    Janson, Andrew P.
    Ojemann, Jeffrey G.
    Brooks, Dana H.
    MacLeod, Rob S.
    Butson, Christopher R.
    Dorval, Alan D.
    FRONTIERS IN NEUROSCIENCE, 2021, 15