Predicting the effects of knee focal articular surface injury with a patient-specific finite element model

被引:38
|
作者
Papaioannou, George [1 ]
Demetropoulos, Constantine K. [2 ]
King, Yang H. [3 ]
机构
[1] Univ Wisconsin Milwaukee, Wisconsin Inst Biomed Hlth Technol, MOVE Ctr, Milwaukee, WI 53201 USA
[2] William Beaumont Hosp, Dept Orthopaed Surg, Royal Oak, MI 48072 USA
[3] Wayne State Univ, Ctr Bioengn, Detroit, MI USA
来源
KNEE | 2010年 / 17卷 / 01期
关键词
Osteochondral defects; Knee contact pressure; Computer aided design; Finite element modeling; CARTILAGE; REPAIR; SIZE;
D O I
10.1016/j.knee.2009.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Successful focal articular surface injury (FAI) repair depends on appropriate matching of the geometrical/material properties of the repaired site, and on the overall dynamic response of the knee to in-vivo loading. There is evidence linking the pathogenesis of lesion progression (e.g. osteoarthritis) to weightbearing site and defect size. The paper investigates further this link by studying the effects of osteochondral defect size on the load distribution at the human knee. Experimental data from cadaver knees (n = 8) loaded at 30 degrees of flexion Was used as input to a validated finite element (FE) model. Contact pressure was assessed for the intact knees and over a range of circular osteochondral defects (5 mill to 20 mm) at 30 degrees of flexion with 700 N axial load. Patient specific FE models and the specific boundary conditions of the experimental set-Lip were used to analyze the osteochondral defects. Stress concentration around the rims of defects 8 mm and smaller was not significant and pressure distribution was dominated by the menisci. Experimental data was confirmed by the model. For defects 10 mm and greater, distribution of peak pressures followed the rim of the defect with a mean distance from the rim of 2.64 mill oil the medial condyle and 2.90 mill on the lateral condyle (model predictions were 2.63 and 2.87 man respectively). Statistical significance was reported when comparing defects that differed by 4 mm or greater (except for the 5 mm case). Peak rim pressure did not significantly increase as defects were enlarged from 10 mm to 20 mm. Peak Values were always significantly higher over the medial femoral condyle. Although the decision to treat osteochondral lesions is multifactorial, the results Of this finite element analysis indicate that a size threshold of 10 mm, may be a useful early adjunct to guide clinical decision-making. This modified FE method can be employed for in-vivo studies. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 50 条
  • [1] The first patient-specific finite element model of the rotational atherectomy
    Celi, S.
    Vaghetti, M.
    Palmieri, C.
    Kull, S.
    Marchi, F.
    Berti, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 347 - 347
  • [2] Patient-specific Finite Element Model of Coronary Artery Stenting
    Razaghi, Reza
    Karimi, Alireza
    Taheri, Ramezan Ali
    CURRENT PHARMACEUTICAL DESIGN, 2018, 24 (37) : 4492 - 4502
  • [3] Patient-specific finite element model of the hip muscles and bones
    Jolivet, Erwan
    Laredo, Jean-Denis
    Bonneau, Dominique
    Skalli, Wafa
    EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2009, 18 (01): : 117 - 129
  • [4] Validation of a finite element model of pediatric patient-specific mandible
    Zhao, LP
    Patel, PK
    Widera, GEO
    Harris, GF
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1831 - 1834
  • [5] Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
    Shim, Vickie
    Hoech, Andreas
    Grunert, Ronny
    Peldschus, Steffen
    Boehme, Joerg
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [6] Patient-specific finite element modeling of bones
    Poelert, Sander
    Valstar, Edward
    Weinans, Harrie
    Zadpoor, Amir A
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2012, 227 (04) : 464 - 478
  • [7] Patient-specific finite element modeling of bones
    Poelert, Sander
    Valstar, Edward
    Weinans, Harrie
    Zadpoor, Amir A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H4) : 464 - 478
  • [8] Patient-specific Finite Element Model of a Spinal Tumor for Thermal Ablation
    Ding, Jinli
    Nan, Qun
    Liu, Youjun
    APPLIED MECHANICS AND MECHANICAL ENGINEERING II, PTS 1 AND 2, 2012, 138-139 : 937 - 940
  • [9] Patient-specific finite element model to simulate the behaviour of a scoliotic spine
    Lindberg, Anne
    Buechler, Philippe
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 383 - 384
  • [10] Physical validation of a patient-specific contact finite element model of the ankle
    Anderson, Donald D.
    Goldsworthy, Jane K.
    Li, Wendy
    Rudert, M. James
    Tochigi, Yuki
    Brown, Thomas D.
    JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1662 - 1669