Fault Ride-Through Study of PMSG based Offshore Wind Farms during Grid Faults

被引:0
|
作者
Dhiman, Harsh S. [1 ]
Deshpande, Anuradha S. [1 ]
机构
[1] Maharaja Sayajirao Univ Baroda, Fac Technol & Engn, Dept Elect Engn, Vadodara, Gujarat, India
关键词
LVRT-Low Voltage Ride-Through; FACT-Flexible AC Transmission; Permanent Magnet Synchronous Generator (PMSG); Wind Energy Conversion Systems (WECS);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As the wind power penetration continues to increase in the modern day electrification, the stabilized operation of wind farms interconnected with grids pose an alarming situation. Typically for an asymmetric grid fault, whose probability of occurrence is more than 70%, the voltage and VAR profile of the wind farm gets disturbed thus leading to erroneous operation of wind energy conversion system. LVRT (Low Voltage Ride-Through) requirements for the wind energy conversion systems typically for an offshore based grid interconnection are still under discussion. This paper presents a FACT device based LVRT capability, where the FACT device injects lpu reactive current in the grid during asymmetric faults as well as symmetric three phase faults.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Faults in the collection grid of offshore wind farms
    Lunow, Morten Erlandsson
    Holboell, Joachim
    Henriksen, Mogens
    2008 ANNUAL IEEE STUDENT PAPER CONFERENCE, 2008, : 116 - +
  • [22] Developing Transmission Fault Ride-Through Criteria for New Zealand Wind Farms
    Qureshi, W. A.
    Demler, G.
    Nair, N. -K. C.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [23] Fault Ride-Through Control Strategy of Doubly-Fed Wind Turbine Under Symmetrical Grid Faults
    Cui, Jian
    Gao, Xiang
    Xie, Zhen
    Xu, Kebao
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 572 - 576
  • [24] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Ran, Li
    Xiang, Dawei
    Tavner, Peter J.
    Yang, Shunchang
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 1623 - 1623
  • [25] Decoupled-DFIG Fault Ride-Through Strategy for Enhanced Stability Performance During Grid Faults
    Meegahapola, Lasantha Gunaruwan
    Littler, Tim
    Flynn, Damian
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2010, 1 (03) : 152 - 162
  • [26] AC Fault Ride-Through Method of HVDC Interconnector for Islanded AC Grid With Offshore Wind Farm and Loads
    Krneta, Nikola
    Sano, Kenichiro
    IEEE ACCESS, 2024, 12 : 62099 - 62106
  • [27] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Xiang, Dawei
    Ran, Li
    Tavner, Peter J.
    Yang, Shunchang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) : 652 - 662
  • [28] Efficiency and Fault Ride-Through Performance of a Diode-Rectifier- and VSC-Inverter-Based HVDC Link for Offshore Wind Farms
    Bernal-Perez, Soledad
    Ano-Villalba, Salvador
    Blasco-Gimenez, Ramon
    Rodriguez-D'Derlee, Johel
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) : 2401 - 2409
  • [29] Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips
    Sim, Jun-Bo
    Kim, Ki-Cheol
    Son, Rak-Won
    Oh, Joong-Ki
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (06) : 898 - 904
  • [30] High Voltage Ride-Through of Grid-side Converter for PMSG Based Directly Driven Wind Turbines
    Liu Changxian
    He Jing
    Xie Zhen
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 8528 - 8532