Development of a Searchable Database of Cryoablation Simulations for Use in Treatment Planning

被引:11
|
作者
Boas, F. Edward [1 ]
Srimathveeravalli, Govindarajan [1 ]
Durack, Jeremy C. [1 ]
Kaye, Elena A. [2 ]
Erinjeri, Joseph P. [1 ]
Ziv, Etay [1 ]
Maybody, Majid [1 ]
Yarmohammadi, Hooman [1 ]
Solomon, Stephen B. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
关键词
Cryoablation; Simulation; Prediction; Planning; PERCUTANEOUS CRYOABLATION; RADIOFREQUENCY ABLATION; GUIDED CRYOABLATION; LIVER-TUMORS; EXPERIENCE; EFFICACY; THERAPY; SAFETY; TRIAL;
D O I
10.1007/s00270-016-1562-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To create and validate a planning tool for multiple-probe cryoablation, using simulations of ice ball size and shape for various ablation probe configurations, ablation times, and types of tissue ablated. Materials and Methods Ice ball size and shape was simulated using the Pennes bioheat equation. Five thousand six hundred and seventy different cryoablation procedures were simulated, using 1-6 cryoablation probes and 1-2 cm spacing between probes. The resulting ice ball was measured along three perpendicular axes and recorded in a database. Simulated ice ball sizes were compared to gel experiments (26 measurements) and clinical cryoablation cases (42 measurements). The clinical cryoablation measurements were obtained from a HIPAA-compliant retrospective review of kidney and liver cryoablation procedures between January 2015 and February 2016. Finally, we created a web-based cryoablation planning tool, which uses the cryoablation simulation database to look up the probe spacing and ablation time that produces the desired ice ball shape and dimensions. Results Average absolute error between the simulated and experimentally measured ice balls was 1 mm in gel experiments and 4 mm in clinical cryoablation cases. The simulations accurately predicted the degree of synergy in multiple-probe ablations. The cryoablation simulation database covers a wide range of ice ball sizes and shapes up to 9.8 cm. Conclusion Cryoablation simulations accurately predict the ice ball size in multiple-probe ablations. The cryoablation database can be used to plan ablation procedures: given the desired ice ball size and shape, it will find the number and type of probes, probe configuration and spacing, and ablation time required.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 50 条
  • [11] The development and use of a crystallographic database
    Gorbitz, Carl Henrik
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE CRYSTAL ENGINEERING AND MATERIALS, 2016, 72 : 167 - 168
  • [12] Creation of a colorectal surgical database: planning and development
    Gormley, C.
    De Marchi, J.
    Joyce, W. P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 : S62 - S63
  • [13] A pre-evacuation database for use in egress simulations
    Lovreglio, R.
    Kuligowski, E.
    Gwynne, S.
    Boyce, K.
    FIRE SAFETY JOURNAL, 2019, 105 : 107 - 128
  • [14] DESIGN OF A RELATIONAL DATABASE FOR THE TREATMENT OF PLANNING MEMORIES
    Buenaga Chapado, Juan A.
    De Cos Guerra, Olga
    Diez Diez, Carlos
    De Meer Lecha-Marzo, Angela
    Pesquera Rios, Ines
    GEOFOCUS-REVISTA INTERNACIONAL DE CIENCIA Y TECNOLOGIA DE LA INFORMACION GEOGRAFICA, 2005, (05):
  • [15] First searchable database for DNA profiles of human cell lines:: Sequential use of fingerprint techniques for authentication
    Dirks, W
    Macleod, RAF
    Jäger, K
    Milch, H
    Drexler, HG
    CELLULAR AND MOLECULAR BIOLOGY, 1999, 45 (06) : 841 - 853
  • [16] Agricultural Conservation Planning Framework: 3. Land Use and Field Boundary Database Development and Structure
    Tomer, Mark D.
    James, David E.
    Sandoval-Green, Claudette M. J.
    JOURNAL OF ENVIRONMENTAL QUALITY, 2017, 46 (03) : 676 - 686
  • [17] The WG Fractography Online Database - stage of development and planning
    Bettge, D.
    Schmies, L.
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2023, 60 (09): : 569 - 579
  • [18] Use of in vivo Raman spectroscopy and cryoablation for diagnosis and treatment of bladder cancer
    Liu, Yufei
    Ye, Fangdie
    Yang, Chen
    Jiang, Haowen
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 308
  • [19] Use of Cryoablation and Osteoplasty Reinforced with Kirschner Wires in the Treatment of Femoral Metastasis
    Ahmed Kamel Abdel-Aal
    Edgar S. Underwood
    Souheil Saddekni
    CardioVascular and Interventional Radiology, 2012, 35 : 1211 - 1215
  • [20] Use of Cryoablation and Osteoplasty Reinforced with Kirschner Wires in the Treatment of Femoral Metastasis
    Abdel-Aal, Ahmed Kamel
    Underwood, Edgar S.
    Saddekni, Souheil
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (05) : 1211 - 1215