An experimental study of endovascular brachytherapy using liquid 32P filled balloon catheter

被引:0
|
作者
Wang, RS [1 ]
Huo, Y [1 ]
Chen, M [1 ]
Liu, ZP [1 ]
Zhu, GY [1 ]
机构
[1] Beijing Med Univ, Teaching Hosp 1, Beijing 100034, Peoples R China
关键词
brachytherapy; restenosis; interventional therapy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To observe the effect of endovascular brachytherapy on the prevention of restenosis after interveneional therapy and to investigate its possible mechanisms. Methods In the balloon-injuried rabbit model, pathological sections of iliac arteries were observed and the changes of vascular histomorphology were estimated by computer analysis of photomicrograms. Using immunohistochemical techniques, proliferating cell nuclear antigen (PCNA) was quantified to assess the proliferation of vascular smooth muscle cells. Results After rabbit iliac arteries were injured by balloon overstretch angioplasty, neointima were shown to be less proliferative in the irradiated group than in the control group, from PCNA scores. The formation of neointima was suppressed with the external elastic laminar area increasing and without the luminal area decreasing in the irradiation group. Conclusion Endovascular brachytherapy using a liquid P-32 filled balloon catheter system could prevent restenosis possibly by inhibiting the formation of neointima and improving positive vascular remodeling.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 50 条
  • [21] Separation of phosphorous by liquid–liquid extraction for the measurement of 32P
    H. N. Lee
    S. H. Kang
    S. D. Yang
    S. C. Sohn
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 284 : 513 - 517
  • [22] Dose perturbation of a novel cobalt chromium coronary stent on intravascular brachytherapy 32P catheter-based source
    Mourtada, F
    Horton, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1387 - 1387
  • [23] DRY COUNTING OF 32P IN LIQUID SCINTILLATION COUNTERS
    HULSEN, W
    PRENZEL, U
    ANALYTICAL BIOCHEMISTRY, 1968, 26 (03) : 483 - &
  • [24] Endovascular beta irradiation using 32P radioactive platinum coils for the treatment of cerebral aneurysms
    Leblanc, P
    Janicki, C
    Morel, F
    Raymond, J
    Roorda, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1318 - 1318
  • [25] Determination of surface dose rate of indigenous 32P patch brachytherapy source by experimental and Monte Carlo methods
    Kumar, Sudhir
    Srinivasan, P.
    Sharma, S. D.
    Saxena, Sanjay Kumar
    Bakshi, A. K.
    Dash, Ashutosh
    Babu, D. A. R.
    Sharma, D. N.
    APPLIED RADIATION AND ISOTOPES, 2015, 103 : 120 - 127
  • [26] Measurement of radiation absorbed dose in endovascular Ho-166 brachytherapy using a balloon angio-catheter
    Joh, CW
    Park, CH
    Kang, HJ
    Oh, YT
    Chun, MS
    Kim, HS
    Choi, BIW
    Park, KB
    Kim, YM
    Kim, KH
    Vahc, YW
    Jang, JS
    Lee, BK
    NUCLEAR MEDICINE COMMUNICATIONS, 2000, 21 (10) : 959 - 964
  • [27] A preliminary safety assessment of vertebral augmentation with 32P brachytherapy bone cement
    Keyak, Joyce H.
    Eijansantos, Mando L.
    Rosecrance, Katherine G.
    Wong, Daniel
    Feizi, Sayeh
    Meldosian, Aleen L.
    Peddinti, Pranav
    Les, Clifford M.
    Skinner, Harry B.
    Sehgal, Varun
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (07):
  • [28] Irradiation dose for personnel during brachytherapy of malignant neoplasms with 32P microsources
    V. F. Stepanenko
    T. V. Kolyzhenkov
    D. V. Dubov
    A. F. Tsyb
    Atomic Energy, 2008, 105 : 298 - 302
  • [29] Separation of phosphorous by liquid-liquid extraction for the measurement of 32P
    Lee, H. N.
    Kang, S. H.
    Yang, S. D.
    Sohn, S. C.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 284 (03) : 513 - 517
  • [30] Novel dose calculation and characterization of 32P intravascular brachytherapy stent source
    Sadeghi, M.
    Kiavar, O.
    Saidi, P.
    Fatehi, R.
    KERNTECHNIK, 2011, 76 (05) : 367 - 372