Simultaneous lead isotope ratio and gold-lead-bismuth concentration analysis of silver by laser ablation MC-ICP-MS

被引:6
|
作者
Standish, Christopher D. [1 ]
Merkel, Stephen W. [2 ,3 ]
Hsieh, Yu-Te [4 ]
Kershaw, Jane [2 ]
机构
[1] Univ Southampton, Sch Ocean & Earth Sci, Natl Oceanog Ctr Southampton, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
[2] Univ Oxford, Sch Archaeol, 1 South Parks Rd, Oxford OX1 3TG, England
[3] Deutsch Bergbau Museum Bochum, Abt Forsch, Bergbaumuseum 31, D-44791 Bochum, Germany
[4] Univ Oxford, Dept Earth Sci, South Parks Rd, Oxford OX1 3AN, England
基金
欧洲研究理事会;
关键词
Lead isotopes; Laser ablation; MC-ICP-MS; Silver; Dirhams; PLASMA-MASS SPECTROMETRY; PB ISOTOPES; METALS;
D O I
10.1016/j.jas.2020.105299
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
A new approach is presented for the simultaneous analysis of lead isotope ratios and gold, lead, and bismuth concentrations in metallic silver using nanosecond laser ablation multi-collector inductively-coupled plasma mass spectrometry (LA-MC-ICP-MS). Corrections for both isotope and concentration analyses are performed using an in-house matrix matched silver reference material RM3834. Accuracy and external reproducibility are demonstrated by repeat analyses of a further seven silver reference materials all characterised by solution (MC)-ICP-MS approaches. Typical internal precisions, expressed as two relative standard errors (S.E.) of the mean of , the cycles comprising one analysis, are <0.5% for (206)pb/(204)pb, Pb-207/Pb-204 and Pb-208/Pb-204, and <0.03% for Pb-207/Pb-206 and Pb-208/Pb-206. External reproducibilities, based on repeat analyses over a 10 month period and , expressed as two relative standard deviations (S.D.) of the mean, are <0.4% for Pb-206/Pb-204, Pb-207/Pb-204 and Pb-208/Pb-204 and <0.2% for Pb-207/Pb-206 and Pb-208/Pb-206. Internal precisions and external reproducibilities of gold, lead and bismuth concentration analyses are typically <25%. Data are consistent with solution-based approaches. Methods are further demonstrated through analyses of a set of Islamic silver dirhams from the mint of al-Muhammadiyya, highlighting their applicability to geochemical studies of archaeological artefacts.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Identification of Marchfeld asparagus using Sr isotope ratio measurements by MC-ICP-MS
    Swoboda, S.
    Brunner, M.
    Boulyga, S. F.
    Galler, P.
    Horacek, M.
    Prohaska, T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) : 487 - 494
  • [42] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [43] Determination of lead isotopic ratios in ferromanganese crust by using MC-ICP-MS and NanoSIMS
    Takata, Y.
    Tanimzu, A.
    Takahata, N.
    Amakawa, H.
    Sano, Y.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A996 - A996
  • [44] Strontium isotope ratios in fossil teeth from South Africa: assessing laser ablation MC-ICP-MS analysis and the extent of diagenesis
    Copeland, Sandi R.
    Sponheimer, Matt
    Lee-Thorp, Julia A.
    le Roux, Petrus J.
    de Ruiter, Darryl J.
    Richards, Michael P.
    JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2010, 37 (07) : 1437 - 1446
  • [45] A newly synthesized reference material for in situ sulfur isotope measurement of sphalerite using laser ablation MC-ICP-MS
    Nie, Xiaojuan
    Bao, Zhian
    Zong, Chunlei
    Lv, Nan
    Chen, Kaiyun
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (05) : 1065 - 1075
  • [46] Synthesis of molybdenite reference materials for in situ molybdenum and sulfur isotope measurement using laser ablation MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Lv, Nan
    Yang, Wenqiang
    Nie, Xiaojuan
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (06) : 1503 - 1513
  • [47] A validated analytical procedure for boron isotope analysis in plants by MC-ICP-MS
    Xiao, Jun
    Vogl, Jochen
    Rosner, Martin
    Deng, Li
    Jin, Zhangdong
    TALANTA, 2019, 196 : 389 - 394
  • [48] In-situ Fe isotopic fractionation determination by laser ablation MC-ICP-MS
    Tunheng, A
    Hirata, T
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A381 - A381
  • [49] Direct in situ dating of titanite in biotextures using laser ablation MC-ICP-MS
    Fliegel, Daniel
    Mcloughlin, Nicola
    Kosler, Jan
    Banerjee, Neil
    Simonetti, Antonio
    Furnes, Harald
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A274 - A274
  • [50] Environmental forensic application of lead isotope ratio determination: A case study using laser ablation sector ICP-MS
    Ghazi, AM
    Millette, JR
    ENVIRONMENTAL FORENSICS, 2004, 5 (02) : 97 - 108